-
1
-
-
30044437888
-
Comparison of hemorrhage control agents applied to lethal extremity arterial hemorrhages in swine
-
Acheson E.M., Kheirabadi B.S., Deguzman R., et al. Comparison of hemorrhage control agents applied to lethal extremity arterial hemorrhages in swine. J Trauma 59 (2005) 865-875
-
(2005)
J Trauma
, vol.59
, pp. 865-875
-
-
Acheson, E.M.1
Kheirabadi, B.S.2
Deguzman, R.3
-
2
-
-
0021378321
-
The causes of death in conventional land warfare: implications for combat casualty care research
-
Bellamy R.F. The causes of death in conventional land warfare: implications for combat casualty care research. Mil Med 149 (1984) 55-62
-
(1984)
Mil Med
, vol.149
, pp. 55-62
-
-
Bellamy, R.F.1
-
3
-
-
0027966136
-
Death in the operating room: an analysis of a multi-center experience
-
Hoyt D.B., Bulger E.M., and Knudson M.M. Death in the operating room: an analysis of a multi-center experience. J Trauma 37 (1994) 426-432
-
(1994)
J Trauma
, vol.37
, pp. 426-432
-
-
Hoyt, D.B.1
Bulger, E.M.2
Knudson, M.M.3
-
4
-
-
0031983293
-
Efficacy of a dry fibrin sealant dressing for hemorrhage control after ballistic injury
-
Holcomb J.B., MacPhee M., and Hetz S. Efficacy of a dry fibrin sealant dressing for hemorrhage control after ballistic injury. Arch Surg 133 (1998) 32-35
-
(1998)
Arch Surg
, vol.133
, pp. 32-35
-
-
Holcomb, J.B.1
MacPhee, M.2
Hetz, S.3
-
6
-
-
0026633216
-
The hemostatic effect of deacetylated chitin membrane on peritoneal injury in rabbit model
-
Fukasawa M., Abe H., and Masaoka T. The hemostatic effect of deacetylated chitin membrane on peritoneal injury in rabbit model. Surg Today 22 (1992) 333-338
-
(1992)
Surg Today
, vol.22
, pp. 333-338
-
-
Fukasawa, M.1
Abe, H.2
Masaoka, T.3
-
7
-
-
0030877569
-
Hemostatic efficacy of a fibrin sealant-based topical agent in femoral artery injury model: a randomized, blinded, placebo-controlled study
-
Jackson M.R., Friedman S.A., and Carter A.J. Hemostatic efficacy of a fibrin sealant-based topical agent in femoral artery injury model: a randomized, blinded, placebo-controlled study. J Vasc Surg 26 (1997) 274-280
-
(1997)
J Vasc Surg
, vol.26
, pp. 274-280
-
-
Jackson, M.R.1
Friedman, S.A.2
Carter, A.J.3
-
8
-
-
0028920586
-
Efficacy of a fibrin hemostatic bandage in controlling hemorrhage from experimental arterial injuries
-
Larson M.J., Bowersox J.C., and Lim R.C. Efficacy of a fibrin hemostatic bandage in controlling hemorrhage from experimental arterial injuries. Arch Surg 130 (1995) 420-422
-
(1995)
Arch Surg
, vol.130
, pp. 420-422
-
-
Larson, M.J.1
Bowersox, J.C.2
Lim, R.C.3
-
9
-
-
2942705909
-
Application of a zeolite hemostatic agent achieves 100% survival in a lethal model of complex groin injury in swine
-
Alam H.B., Chen Z., and Jaskille A. Application of a zeolite hemostatic agent achieves 100% survival in a lethal model of complex groin injury in swine. J Trauma 56 (2004) 974-983
-
(2004)
J Trauma
, vol.56
, pp. 974-983
-
-
Alam, H.B.1
Chen, Z.2
Jaskille, A.3
-
10
-
-
0038327506
-
The effect of recombinant factor VIIa on noncoagulopathic pigs with grade V liver injuries
-
Schreiber M.A. The effect of recombinant factor VIIa on noncoagulopathic pigs with grade V liver injuries. J Am Coll Surg 196 (2003) 691-697
-
(2003)
J Am Coll Surg
, vol.196
, pp. 691-697
-
-
Schreiber, M.A.1
-
11
-
-
0038339548
-
Blood pressure at which rebleeding occurs after resuscitation in swine with aortic injury
-
Sondeen J.L., Coppes V.G., and Holcomb J.B. Blood pressure at which rebleeding occurs after resuscitation in swine with aortic injury. J Trauma 54 (2003) S110-S117
-
(2003)
J Trauma
, vol.54
-
-
Sondeen, J.L.1
Coppes, V.G.2
Holcomb, J.B.3
-
12
-
-
0038001588
-
Fluid resuscitation in modern combat casualty care: lessons learned from Somalia
-
Holcomb J.B. Fluid resuscitation in modern combat casualty care: lessons learned from Somalia. J Trauma 57 (2004) S46-S51
-
(2004)
J Trauma
, vol.57
-
-
Holcomb, J.B.1
|