메뉴 건너뛰기




Volumn 37, Issue 5, 2009, Pages 279-284

Accuracy of combined maxillary and mandibular repositioning and of soft tissue prediction in relation to maxillary antero-superior repositioning combined with mandibular set back. A computerized cephalometric evaluation of the immediate postsurgical outcome using the TIOPS planning system

Author keywords

computerized; orthognathic surgery; prediction

Indexed keywords

ADOLESCENT; ADULT; ARTICLE; CEPHALOMETRY; FACE DEFORMITY; FEMALE; HUMAN; MAJOR CLINICAL STUDY; MALE; MANDIBLE; MAXILLA; ORTHOGNATHIC SURGERY; OSTEOSYNTHESIS; SIMULATION; TREATMENT OUTCOME;

EID: 67349126973     PISSN: 10105182     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jcms.2008.12.003     Document Type: Article
Times cited : (26)

References (34)
  • 1
    • 0031299230 scopus 로고    scopus 로고
    • Surgical prediction reliability: a comparison of two computer software systems
    • Aharon P.A., Elsig S., and Cisneros G.J. Surgical prediction reliability: a comparison of two computer software systems. Int J Adult Orthod Orthognath Surg 12 (1997) 65-78
    • (1997) Int J Adult Orthod Orthognath Surg , vol.12 , pp. 65-78
    • Aharon, P.A.1    Elsig, S.2    Cisneros, G.J.3
  • 2
    • 0022552621 scopus 로고
    • Facial changes associated with surgical advancement of the lip and maxilla
    • Carlotti A.E., Ascaffenburg P.H., and Schendel S.A. Facial changes associated with surgical advancement of the lip and maxilla. J Oral Maxillofac Surg 44 (1986) 593-596
    • (1986) J Oral Maxillofac Surg , vol.44 , pp. 593-596
    • Carlotti, A.E.1    Ascaffenburg, P.H.2    Schendel, S.A.3
  • 4
    • 1642526473 scopus 로고    scopus 로고
    • The accuracy of preoperative orthognathic predictions
    • Cousley R.R., and Grant E. The accuracy of preoperative orthognathic predictions. Br J Oral Maxillofac Surg 42 (2004) 96-104
    • (2004) Br J Oral Maxillofac Surg , vol.42 , pp. 96-104
    • Cousley, R.R.1    Grant, E.2
  • 6
    • 0034281214 scopus 로고    scopus 로고
    • Accuracy of a computerized method of predicting soft-tissue changes from orthognathic surgery
    • Curtis T.J., Casko J.S., Jakobsen J.R., and Southard T.E. Accuracy of a computerized method of predicting soft-tissue changes from orthognathic surgery. J Clin Orthod 34 (2000) 524-530
    • (2000) J Clin Orthod , vol.34 , pp. 524-530
    • Curtis, T.J.1    Casko, J.S.2    Jakobsen, J.R.3    Southard, T.E.4
  • 7
    • 0030884988 scopus 로고    scopus 로고
    • Computerized cephalometric evaluation of orthognathic surgical precision and stability in relation to maxillary superior repositioning combined with mandibular advancement or setback
    • Donatsky O., Bjørn-Jørgensen J., Holmqvist-Larsen M., and Hillerup S. Computerized cephalometric evaluation of orthognathic surgical precision and stability in relation to maxillary superior repositioning combined with mandibular advancement or setback. J Oral Maxillofac Surg 55 (1997) 1071-1079
    • (1997) J Oral Maxillofac Surg , vol.55 , pp. 1071-1079
    • Donatsky, O.1    Bjørn-Jørgensen, J.2    Holmqvist-Larsen, M.3    Hillerup, S.4
  • 8
    • 0026784432 scopus 로고
    • Computerized cephalometric orthognathic surgical simulation, prediction and postoperative evaluation of precision
    • Donatsky O., Hillerup S., Bjørn-Jørgensen J., and Jacobsen P.U. Computerized cephalometric orthognathic surgical simulation, prediction and postoperative evaluation of precision. Int J Oral Maxillofac Surg 21 (1992) 199-203
    • (1992) Int J Oral Maxillofac Surg , vol.21 , pp. 199-203
    • Donatsky, O.1    Hillerup, S.2    Bjørn-Jørgensen, J.3    Jacobsen, P.U.4
  • 9
    • 0026473269 scopus 로고
    • Control of vertical dimension during maxillary orthognathic surgery. A clinical trial comparing internal and external fixed reference points
    • Ferguson J.W., and Luyk N.H. Control of vertical dimension during maxillary orthognathic surgery. A clinical trial comparing internal and external fixed reference points. J Craniomaxillofac Surg 20 (1992) 333-336
    • (1992) J Craniomaxillofac Surg , vol.20 , pp. 333-336
    • Ferguson, J.W.1    Luyk, N.H.2
  • 10
    • 0032926886 scopus 로고    scopus 로고
    • Changes in soft tissue profile after sagittal split ramus osteotomy and retropositioning of the mandible
    • Gaggl A., Schultes G., and Karcher H. Changes in soft tissue profile after sagittal split ramus osteotomy and retropositioning of the mandible. J Oral Maxillofac Surg 57 (1999) 542-546
    • (1999) J Oral Maxillofac Surg , vol.57 , pp. 542-546
    • Gaggl, A.1    Schultes, G.2    Karcher, H.3
  • 11
    • 0031299372 scopus 로고    scopus 로고
    • A comparison of a computer-based orthognathic surgery prediction system to postsurgical results
    • Gerbo L.R., Poulton D.R., Covell D.A., and Russell C.A. A comparison of a computer-based orthognathic surgery prediction system to postsurgical results. Int J Adult Orthod Orthognath Surg 12 (1997) 55-63
    • (1997) Int J Adult Orthod Orthognath Surg , vol.12 , pp. 55-63
    • Gerbo, L.R.1    Poulton, D.R.2    Covell, D.A.3    Russell, C.A.4
  • 13
    • 0024677895 scopus 로고
    • The accuracy of computer generated prediction tracings
    • Hing N.R. The accuracy of computer generated prediction tracings. Int J Oral Maxillofac Surg 18 (1989) 148-151
    • (1989) Int J Oral Maxillofac Surg , vol.18 , pp. 148-151
    • Hing, N.R.1
  • 15
    • 35148852296 scopus 로고    scopus 로고
    • The validity of a computerized simulation system for orthognathic surgery (CASSOS) for planning the surgical correction of class III skeletal deformities: single jaw versus bimaxillary surgery
    • Jones R.M., Khambay B.S., McHugh S., and Ayoub A.F. The validity of a computerized simulation system for orthognathic surgery (CASSOS) for planning the surgical correction of class III skeletal deformities: single jaw versus bimaxillary surgery. Int J Oral Maxillofac Surg 36 (2007) 900-908
    • (2007) Int J Oral Maxillofac Surg , vol.36 , pp. 900-908
    • Jones, R.M.1    Khambay, B.S.2    McHugh, S.3    Ayoub, A.F.4
  • 16
    • 0025050643 scopus 로고
    • Planning and control of vertical dimension in Le Fort I osteotomies
    • Kahnberg K.-E., Sunzel B., and Åstrand P. Planning and control of vertical dimension in Le Fort I osteotomies. J Craniomaxillofac Surg 18 (1990) 267-270
    • (1990) J Craniomaxillofac Surg , vol.18 , pp. 267-270
    • Kahnberg, K.-E.1    Sunzel, B.2    Åstrand, P.3
  • 17
    • 0028390975 scopus 로고
    • The validity of the prediction of soft tissue profile changes after Le Fort I osteotomy using the dentofacial planner computer software
    • Konstiantos K.A., O'Reilly M.T., and Close J. The validity of the prediction of soft tissue profile changes after Le Fort I osteotomy using the dentofacial planner computer software. Am J Orthod Dentofacial Orthop 105 (1994) 241-249
    • (1994) Am J Orthod Dentofacial Orthop , vol.105 , pp. 241-249
    • Konstiantos, K.A.1    O'Reilly, M.T.2    Close, J.3
  • 18
    • 0024553472 scopus 로고
    • Orthognathic surgery without the use of postoperative intermaxillary fixation. A clinical and cephalometric evaluation of surgical correction of mandibular and maxillary deformities
    • Krekmanov L. Orthognathic surgery without the use of postoperative intermaxillary fixation. A clinical and cephalometric evaluation of surgical correction of mandibular and maxillary deformities. Swed Dent J Suppl 61 (1989) 1-370
    • (1989) Swed Dent J Suppl , vol.61 , pp. 1-370
    • Krekmanov, L.1
  • 19
    • 0031995425 scopus 로고    scopus 로고
    • Soft and hard tissue changes in class III patients treated by bimaxillary surgery
    • Lin S.-S., and Kerr W.J.S. Soft and hard tissue changes in class III patients treated by bimaxillary surgery. Eur J Orthod 20 (1998) 25-33
    • (1998) Eur J Orthod , vol.20 , pp. 25-33
    • Lin, S.-S.1    Kerr, W.J.S.2
  • 20
    • 0037371708 scopus 로고    scopus 로고
    • The accuracy of video imaging prediction in soft tissue outcome after bimaxillary orthognathic surgery
    • Lu C.H., Ko E.W., and Huang C.S. The accuracy of video imaging prediction in soft tissue outcome after bimaxillary orthognathic surgery. J Oral Maxillofac Surg 61 (2003) 333-342
    • (2003) J Oral Maxillofac Surg , vol.61 , pp. 333-342
    • Lu, C.H.1    Ko, E.W.2    Huang, C.S.3
  • 22
    • 0020956899 scopus 로고
    • An evaluation of soft tissue changes resulting from Le Fort I maxillary surgery
    • Mansour S., Burstone C., and Legan H. An evaluation of soft tissue changes resulting from Le Fort I maxillary surgery. Am J Orthod 84 (1983) 37-47
    • (1983) Am J Orthod , vol.84 , pp. 37-47
    • Mansour, S.1    Burstone, C.2    Legan, H.3
  • 23
    • 0026486194 scopus 로고
    • Le Fort I maxillary osteotomy: is it possible to accurately produce planned pre-operative movements?
    • McCance A.M., Moss J.P., and James D.R. Le Fort I maxillary osteotomy: is it possible to accurately produce planned pre-operative movements?. Br J Oral Maxillofac Surg 30 (1992) 369-376
    • (1992) Br J Oral Maxillofac Surg , vol.30 , pp. 369-376
    • McCance, A.M.1    Moss, J.P.2    James, D.R.3
  • 24
    • 0023871090 scopus 로고
    • Refined intraoperative repositioning of the osteotomized maxilla in relation to the skull and TMJ
    • Neubert J., Bitter K., and Somsiri S. Refined intraoperative repositioning of the osteotomized maxilla in relation to the skull and TMJ. J Craniomaxillofac Surg 16 (1988) 8-12
    • (1988) J Craniomaxillofac Surg , vol.16 , pp. 8-12
    • Neubert, J.1    Bitter, K.2    Somsiri, S.3
  • 25
    • 34248195362 scopus 로고    scopus 로고
    • The accuracy of computer-assisted surgical planning in soft tissue prediction following orthognathic surgery
    • Pektas Z.O., Kircelli B.H., Cilasun U., and Uckan S. The accuracy of computer-assisted surgical planning in soft tissue prediction following orthognathic surgery. Int J Med Robot 3 (2007) 64-71
    • (2007) Int J Med Robot , vol.3 , pp. 64-71
    • Pektas, Z.O.1    Kircelli, B.H.2    Cilasun, U.3    Uckan, S.4
  • 26
    • 0026665019 scopus 로고
    • A modified Boley gauge for accurate measurement during maxillary osteotomies
    • Perkins S.J., Newhouse R.F., and Bach D.E. A modified Boley gauge for accurate measurement during maxillary osteotomies. J Oral Maxillofac Surg 50 (1992) 1018-1019
    • (1992) J Oral Maxillofac Surg , vol.50 , pp. 1018-1019
    • Perkins, S.J.1    Newhouse, R.F.2    Bach, D.E.3
  • 27
    • 21844439444 scopus 로고    scopus 로고
    • Dolphin imaging software: an analysis of the accuracy of cephalometric digitation and orthognathic prediction
    • Power G., Breckon J., Sheriff M., and McDonald F. Dolphin imaging software: an analysis of the accuracy of cephalometric digitation and orthognathic prediction. Int J Oral Maxillofac Surg 34 (2005) 619-626
    • (2005) Int J Oral Maxillofac Surg , vol.34 , pp. 619-626
    • Power, G.1    Breckon, J.2    Sheriff, M.3    McDonald, F.4
  • 28
    • 0025345493 scopus 로고
    • An assessment of the predictability of maxillary surgery
    • Polido W.D., Ellis E., and Sinn D.P. An assessment of the predictability of maxillary surgery. J Oral Maxillofac Surg 48 (1990) 697-701
    • (1990) J Oral Maxillofac Surg , vol.48 , pp. 697-701
    • Polido, W.D.1    Ellis, E.2    Sinn, D.P.3
  • 29
    • 0026345936 scopus 로고
    • An assessment of predictability of maxillary repositioning
    • Polido W.D., Ellis E., and Sinn D.P. An assessment of predictability of maxillary repositioning. Int J Oral Maxillofac Surg 20 (1991) 349-352
    • (1991) Int J Oral Maxillofac Surg , vol.20 , pp. 349-352
    • Polido, W.D.1    Ellis, E.2    Sinn, D.P.3
  • 30
    • 0023837421 scopus 로고
    • Lip-nasal aesthetics following Le Fort I osteotomy
    • Rosen H.M. Lip-nasal aesthetics following Le Fort I osteotomy. Plastic Reconstr Surg 81 (1988) 171-178
    • (1988) Plastic Reconstr Surg , vol.81 , pp. 171-178
    • Rosen, H.M.1
  • 32
    • 0024199980 scopus 로고
    • A comparison of two measures for repositioning the maxilla during orthognathic surgery
    • Stanchina R., Ellis E., Gallo W.J., and Fonseca R.J. A comparison of two measures for repositioning the maxilla during orthognathic surgery. Int J Adult Orthod Orthognath Surg 3 (1988) 149-154
    • (1988) Int J Adult Orthod Orthognath Surg , vol.3 , pp. 149-154
    • Stanchina, R.1    Ellis, E.2    Gallo, W.J.3    Fonseca, R.J.4
  • 33
    • 0031296779 scopus 로고    scopus 로고
    • Evaluation of video imaging prediction in combined maxillary and mandibular orthognathic surgery
    • Upton P.M., Sadowsky P.L., Sarver D.M., and Heaven T.J. Evaluation of video imaging prediction in combined maxillary and mandibular orthognathic surgery. Am J Orthod Dentofacial Orthop 112 (1997) 656-665
    • (1997) Am J Orthod Dentofacial Orthop , vol.112 , pp. 656-665
    • Upton, P.M.1    Sadowsky, P.L.2    Sarver, D.M.3    Heaven, T.J.4
  • 34
    • 0022728255 scopus 로고
    • Predictability of maxillary surgery. A comparison of internal and external reference marks
    • Van Sickels J.E., Larsen A.J., and Triplett G. Predictability of maxillary surgery. A comparison of internal and external reference marks. Oral Surg Oral Med Oral Pathol 61 (1986) 542-545
    • (1986) Oral Surg Oral Med Oral Pathol , vol.61 , pp. 542-545
    • Van Sickels, J.E.1    Larsen, A.J.2    Triplett, G.3