메뉴 건너뛰기




Volumn 86, Issue 11, 2009, Pages 2443-2450

Thermodynamic analysis of the reverse Joule-Brayton cycle heat pump for domestic heating

Author keywords

Domestic heating; Heat pump; Reverse Joule Brayton

Indexed keywords

BRAYTON CYCLE; HEAT PUMP SYSTEMS; HEAT TRANSFER; PUMPS; TEMPERATURE; THERMOANALYSIS;

EID: 67349117823     PISSN: 03062619     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.apenergy.2009.02.012     Document Type: Article
Times cited : (47)

References (24)
  • 1
    • 33646416784 scopus 로고    scopus 로고
    • A comparative assessment of future heat and power sources for the UK domestic sector
    • Cockroft J., and Kelly N. A comparative assessment of future heat and power sources for the UK domestic sector. Energy Convers Manage 47 (2006) 2349-2360
    • (2006) Energy Convers Manage , vol.47 , pp. 2349-2360
    • Cockroft, J.1    Kelly, N.2
  • 4
    • 0029308297 scopus 로고
    • Prospects for real-gas reversed brayton cycle heat pumps
    • Angelion G., and Invernezzi C. Prospects for real-gas reversed brayton cycle heat pumps. Int J Refrig 18 4 (1995) 272-280
    • (1995) Int J Refrig , vol.18 , Issue.4 , pp. 272-280
    • Angelion, G.1    Invernezzi, C.2
  • 5
    • 3343022815 scopus 로고    scopus 로고
    • Air cycle cooling and heating, part 2: a mathematical model for the transient behaviour of fixed matrix regenerators
    • Fleming J., Li L., and Vander Wekken B. Air cycle cooling and heating, part 2: a mathematical model for the transient behaviour of fixed matrix regenerators. Int J Energy Res 22 (1998)
    • (1998) Int J Energy Res , vol.22
    • Fleming, J.1    Li, L.2    Vander Wekken, B.3
  • 6
    • 0036836326 scopus 로고    scopus 로고
    • Energy efficiency analysis of air cycle heat pump dryers
    • Braun J., Bansal P., and Groll E. Energy efficiency analysis of air cycle heat pump dryers. Int J Refrig 25 7 (2002) 954-965
    • (2002) Int J Refrig , vol.25 , Issue.7 , pp. 954-965
    • Braun, J.1    Bansal, P.2    Groll, E.3
  • 7
    • 0030262482 scopus 로고    scopus 로고
    • Optimisation of steady flow refrigeration cycles
    • Wu C., Chen L., and Sun F. Optimisation of steady flow refrigeration cycles. Int J Ambient Energy 17 (1996) 199-206
    • (1996) Int J Ambient Energy , vol.17 , pp. 199-206
    • Wu, C.1    Chen, L.2    Sun, F.3
  • 8
    • 0032017456 scopus 로고    scopus 로고
    • Optimization of steady flow heat pumps
    • Wu C., Chen L., and Sun F. Optimization of steady flow heat pumps. Energy Convers Manage 39 5 (1998) 445-453
    • (1998) Energy Convers Manage , vol.39 , Issue.5 , pp. 445-453
    • Wu, C.1    Chen, L.2    Sun, F.3
  • 9
    • 0033329508 scopus 로고    scopus 로고
    • Performance of real regenerated air heat pumps
    • Chen L., Ni N., Sun F., and Wu C. Performance of real regenerated air heat pumps. Int J Power Energy Syst 19 3 (1999) 231-238
    • (1999) Int J Power Energy Syst , vol.19 , Issue.3 , pp. 231-238
    • Chen, L.1    Ni, N.2    Sun, F.3    Wu, C.4
  • 10
    • 0342879896 scopus 로고    scopus 로고
    • Performance analysis of a closed regenerated heat pump with internal irreversibilities
    • Chen L., Ni N., Wu C., and Sun F. Performance analysis of a closed regenerated heat pump with internal irreversibilities. Int J Energy Res 23 (1999) 1039-1050
    • (1999) Int J Energy Res , vol.23 , pp. 1039-1050
    • Chen, L.1    Ni, N.2    Wu, C.3    Sun, F.4
  • 11
    • 0033101926 scopus 로고    scopus 로고
    • Performance analysis for endoreversible closed regenerated brayton heat pump cycles
    • Ni N., Chen L., Wu C., and Sun F. Performance analysis for endoreversible closed regenerated brayton heat pump cycles. Energy Convers Manage 40 4 (1999) 393-406
    • (1999) Energy Convers Manage , vol.40 , Issue.4 , pp. 393-406
    • Ni, N.1    Chen, L.2    Wu, C.3    Sun, F.4
  • 12
    • 0035819827 scopus 로고    scopus 로고
    • Performance of heat-transfer irreversible regenerated Brayton refrigerators
    • Chen L., Zhou S., Sun F., and Wu C. Performance of heat-transfer irreversible regenerated Brayton refrigerators. J Phys D: Appl Phys 34 (2001) 830-837
    • (2001) J Phys D: Appl Phys , vol.34 , pp. 830-837
    • Chen, L.1    Zhou, S.2    Sun, F.3    Wu, C.4
  • 13
    • 2242454244 scopus 로고    scopus 로고
    • Heating load vs. cop characteristics for irreversible air-heat pump cycles
    • Chen L., Ni N., Wu C., and Sun F. Heating load vs. cop characteristics for irreversible air-heat pump cycles. Int J Power Energy Syst 21 2 (2001) 105-111
    • (2001) Int J Power Energy Syst , vol.21 , Issue.2 , pp. 105-111
    • Chen, L.1    Ni, N.2    Wu, C.3    Sun, F.4
  • 14
    • 33749660843 scopus 로고    scopus 로고
    • Comparison on the optimum performances of the irreversible Brayton refrigeration with regeneration and non-regeneration
    • Zhang Y., Chen J., He J., and Wu C. Comparison on the optimum performances of the irreversible Brayton refrigeration with regeneration and non-regeneration. Appl Therm Eng 27 (2007) 401-407
    • (2007) Appl Therm Eng , vol.27 , pp. 401-407
    • Zhang, Y.1    Chen, J.2    He, J.3    Wu, C.4
  • 16
    • 33750358648 scopus 로고    scopus 로고
    • Performance optimization of quantum Brayton refrigeration cycle working with spin systems
    • He J., Xin Y., and He X. Performance optimization of quantum Brayton refrigeration cycle working with spin systems. Appl Energy 84 (2007) 176-186
    • (2007) Appl Energy , vol.84 , pp. 176-186
    • He, J.1    Xin, Y.2    He, X.3
  • 18
    • 0018308691 scopus 로고
    • The reversed Brayton cycle heat pump - a natural open cycle for HVAC applications
    • Sisto F. The reversed Brayton cycle heat pump - a natural open cycle for HVAC applications. J Eng Power Trans ASME 101 (1979) 162-167
    • (1979) J Eng Power Trans ASME , vol.101 , pp. 162-167
    • Sisto, F.1
  • 19
    • 85020978866 scopus 로고    scopus 로고
    • Dieckmann J, Erickson A, Harvey A, Toscano W. Research and development of an air-cycle heat pump water heater. Waltham (MA): final report for Foster-Miller Associates, Inc.; 1979. ...D.
    • Dieckmann J, Erickson A, Harvey A, Toscano W. Research and development of an air-cycle heat pump water heater. Waltham (MA): final report for Foster-Miller Associates, Inc.; 1979. ...D.
  • 22
    • 5044249301 scopus 로고    scopus 로고
    • Reciprocating Joule-cycle engine for domestic chp systems
    • Moss R., Roskilly A., and Nanda S. Reciprocating Joule-cycle engine for domestic chp systems. Appl Energy 80 (2005) 169-185
    • (2005) Appl Energy , vol.80 , pp. 169-185
    • Moss, R.1    Roskilly, A.2    Nanda, S.3
  • 23
    • 0020907862 scopus 로고
    • A simplistic model of cyclic heat transfer phenomena in closed spaces
    • Lee K. A simplistic model of cyclic heat transfer phenomena in closed spaces. In: Proceedings of the 18th IECEC; 1983. p. 720-3.
    • (1983) Proceedings of the 18th IECEC , pp. 720-723
    • Lee, K.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.