-
3
-
-
0021505465
-
Sensory feedback therapy and theoretical knowledge of motor control and learning
-
Mulder T., and Hultstyn W. Sensory feedback therapy and theoretical knowledge of motor control and learning. Am J Phys Med 63 (1984) 226-243
-
(1984)
Am J Phys Med
, vol.63
, pp. 226-243
-
-
Mulder, T.1
Hultstyn, W.2
-
4
-
-
46749089566
-
Postural destabilization induced by trunk extensor muscles fatigue is suppressed by use of a plantar pressure-based electro-tactile biofeedback
-
10.1007/s00421-008-0768-9
-
Vuillerme N., Pinsault N., Chenu O., Fleury A., Payan Y., and Demongeot J. Postural destabilization induced by trunk extensor muscles fatigue is suppressed by use of a plantar pressure-based electro-tactile biofeedback. Eur J Appl Physiol (2008) 10.1007/s00421-008-0768-9
-
(2008)
Eur J Appl Physiol
-
-
Vuillerme, N.1
Pinsault, N.2
Chenu, O.3
Fleury, A.4
Payan, Y.5
Demongeot, J.6
-
6
-
-
0022293432
-
Delayed sensory feedback in the learning of a novel task
-
Mulder T., and Hultstyn W. Delayed sensory feedback in the learning of a novel task. Psychol Res 47 (1985) 203-209
-
(1985)
Psychol Res
, vol.47
, pp. 203-209
-
-
Mulder, T.1
Hultstyn, W.2
-
7
-
-
0036616617
-
Principles derived from the study of simple skills do not generalize to complex skill learning
-
Wulf G., and Shea C.H. Principles derived from the study of simple skills do not generalize to complex skill learning. Psychon Bull Rev 9 (2002) 185-211
-
(2002)
Psychon Bull Rev
, vol.9
, pp. 185-211
-
-
Wulf, G.1
Shea, C.H.2
-
8
-
-
26444616208
-
Altering asymmetric limb loading after hip arthroplasty using real-time dynamic feedback when walking
-
White S.C., and Lifeso R.M. Altering asymmetric limb loading after hip arthroplasty using real-time dynamic feedback when walking. Arch Phys Med Rehabil 86 (2005) 1958-1963
-
(2005)
Arch Phys Med Rehabil
, vol.86
, pp. 1958-1963
-
-
White, S.C.1
Lifeso, R.M.2
-
10
-
-
0031127592
-
A holter-type, microprocessor-based, rehabilitation instrument for acquisition and storage of plantar pressure data
-
Abu-faraj Z.O., Harris G.F., Alber J.H., and Wertsch J.J. A holter-type, microprocessor-based, rehabilitation instrument for acquisition and storage of plantar pressure data. J Rehabil Res Dev 34 (1997) 187-194
-
(1997)
J Rehabil Res Dev
, vol.34
, pp. 187-194
-
-
Abu-faraj, Z.O.1
Harris, G.F.2
Alber, J.H.3
Wertsch, J.J.4
-
11
-
-
0034891988
-
Monitoring in-shoe plantar pressures, temperature, and humidity: reliability and validity of measures from a portable device
-
Maluf K.S., Morley R.E., Richter E.J., Klaesner J.W., and Mueller M.J. Monitoring in-shoe plantar pressures, temperature, and humidity: reliability and validity of measures from a portable device. Arch Phys Med Rehabil 82 (2001) 1119-1127
-
(2001)
Arch Phys Med Rehabil
, vol.82
, pp. 1119-1127
-
-
Maluf, K.S.1
Morley, R.E.2
Richter, E.J.3
Klaesner, J.W.4
Mueller, M.J.5
-
12
-
-
0034977632
-
In-shoe multisensory data acquisition system
-
Morley R.E., Richter E.J., Klaesner J.W., Maluf K.S., and Mueller M.J. In-shoe multisensory data acquisition system. IEEE Trans Biomed Eng 48 (2001) 815-820
-
(2001)
IEEE Trans Biomed Eng
, vol.48
, pp. 815-820
-
-
Morley, R.E.1
Richter, E.J.2
Klaesner, J.W.3
Maluf, K.S.4
Mueller, M.J.5
-
13
-
-
61349194557
-
The neutral network selection for a medical diagnostic system using an artificial data set
-
Piecha J. The neutral network selection for a medical diagnostic system using an artificial data set. J Comput Inf Tech CIT 9 (2001) 123-132
-
(2001)
J Comput Inf Tech CIT
, vol.9
, pp. 123-132
-
-
Piecha, J.1
-
14
-
-
0034286976
-
A new ambulatory foot pressure device for patients with sensory impairment. A system for continuous measurement of plantar pressure and a feed-back alarm
-
Pataky Z., Faravel L., Da Silva J., and Assal J. A new ambulatory foot pressure device for patients with sensory impairment. A system for continuous measurement of plantar pressure and a feed-back alarm. J Biomech 33 (2000) 1135-1138
-
(2000)
J Biomech
, vol.33
, pp. 1135-1138
-
-
Pataky, Z.1
Faravel, L.2
Da Silva, J.3
Assal, J.4
-
15
-
-
5344223371
-
A real-time plantar pressure feedback device for foot unloading
-
Femery V.G., Moretto P.G., Hespel J.M., Thevenon A., and Lensel G. A real-time plantar pressure feedback device for foot unloading. Arch Phys Med Rehabil 85 (2004) 1724-1728
-
(2004)
Arch Phys Med Rehabil
, vol.85
, pp. 1724-1728
-
-
Femery, V.G.1
Moretto, P.G.2
Hespel, J.M.3
Thevenon, A.4
Lensel, G.5
-
16
-
-
0030805278
-
Gait pattern alteration by functional sensory substitution in healthy subjects and in diabetic subjects with peripheral neuropathy
-
Walker S.C., Helm P.A., and Lavery L.A. Gait pattern alteration by functional sensory substitution in healthy subjects and in diabetic subjects with peripheral neuropathy. Arch Phys Med Rehabil 78 (1997) 853-856
-
(1997)
Arch Phys Med Rehabil
, vol.78
, pp. 853-856
-
-
Walker, S.C.1
Helm, P.A.2
Lavery, L.A.3
-
17
-
-
0026717848
-
The risk of foot ulceration in diabetic patients with high foot pressure: a prospective study
-
Veves A., Murray H.J., Young M.J., and Boulton A.J. The risk of foot ulceration in diabetic patients with high foot pressure: a prospective study. Diabetologia 35 (1992) 660-663
-
(1992)
Diabetologia
, vol.35
, pp. 660-663
-
-
Veves, A.1
Murray, H.J.2
Young, M.J.3
Boulton, A.J.4
-
19
-
-
67349183077
-
-
Paromed Medizintechnik Gmbh, Neubeueurn, Germany
-
Parotec system instruction manual (1997), Paromed Medizintechnik Gmbh, Neubeueurn, Germany
-
(1997)
Parotec system instruction manual
-
-
-
20
-
-
0034307769
-
Comparison of an in-shoe pressure measurement device to a force plate: concurrent validity of center of pressure measurements
-
Chesnin K.J., Selby-Silversteun L., and Besser M.P. Comparison of an in-shoe pressure measurement device to a force plate: concurrent validity of center of pressure measurements. Gait Posture 12 (2000) 128-133
-
(2000)
Gait Posture
, vol.12
, pp. 128-133
-
-
Chesnin, K.J.1
Selby-Silversteun, L.2
Besser, M.P.3
-
21
-
-
38249030572
-
Intraday reliability of ground reaction force data
-
Devita P., and Bates B.T. Intraday reliability of ground reaction force data. Hum Mov Sci 7 (1988) 73-85
-
(1988)
Hum Mov Sci
, vol.7
, pp. 73-85
-
-
Devita, P.1
Bates, B.T.2
-
22
-
-
0030778188
-
Total contact casts: pressure reduction at ulcer sites and the effect on the contralateral foot
-
Lavery L.A., Vela S.A., Lavery D.C., and Quebedeaux T.L. Total contact casts: pressure reduction at ulcer sites and the effect on the contralateral foot. Arch Phys Med Rehabil 78 (1997) 1268-1271
-
(1997)
Arch Phys Med Rehabil
, vol.78
, pp. 1268-1271
-
-
Lavery, L.A.1
Vela, S.A.2
Lavery, D.C.3
Quebedeaux, T.L.4
-
23
-
-
33744780437
-
Efficacy and mechanism of orthotic devices to unload metatarsal heads in people with diabetes and a history of plantar ulcers
-
Mueller M.J., Lott D.J., Hastings M.K., Commean P.K., Smith K.E., and Pilgram T.K. Efficacy and mechanism of orthotic devices to unload metatarsal heads in people with diabetes and a history of plantar ulcers. Phys Ther 86 (2006) 833-842
-
(2006)
Phys Ther
, vol.86
, pp. 833-842
-
-
Mueller, M.J.1
Lott, D.J.2
Hastings, M.K.3
Commean, P.K.4
Smith, K.E.5
Pilgram, T.K.6
-
24
-
-
0036142848
-
Simultaneous measurement of plantar pressure, and shear forces in diabetic individuals
-
Perry J.E., Hall J.O., and Davis B.L. Simultaneous measurement of plantar pressure, and shear forces in diabetic individuals. Gait Posture 15 (2002) 101-107
-
(2002)
Gait Posture
, vol.15
, pp. 101-107
-
-
Perry, J.E.1
Hall, J.O.2
Davis, B.L.3
-
25
-
-
5344244791
-
A conductive polymer pressure sensor
-
Proc. 10th Annu. Int. Conf. IEEE
-
Maalej N., Bath S., and Zhu H. A conductive polymer pressure sensor. Proc. 10th Annu. Int. Conf. IEEE. Eng Med Biol Soc (1988) 805-806
-
(1988)
Eng Med Biol Soc
, pp. 805-806
-
-
Maalej, N.1
Bath, S.2
Zhu, H.3
-
26
-
-
3242726682
-
Pressure relief and load redistribution by custom-made insoles in diabetic patients with neuropathy and foot deformity
-
Bus S.A., Ulbrecht J.S., and Cavanagh P.R. Pressure relief and load redistribution by custom-made insoles in diabetic patients with neuropathy and foot deformity. Clin Biomech 19 (2004) 629-638
-
(2004)
Clin Biomech
, vol.19
, pp. 629-638
-
-
Bus, S.A.1
Ulbrecht, J.S.2
Cavanagh, P.R.3
-
27
-
-
33746315134
-
Video game-based exercises for balance rehabilitation: a single subject design
-
Beker A.L., Szturm T., Moussavi Z.K., and Nett C. Video game-based exercises for balance rehabilitation: a single subject design. Arch Phys Med Rehabil 87 (2006) 1141-1149
-
(2006)
Arch Phys Med Rehabil
, vol.87
, pp. 1141-1149
-
-
Beker, A.L.1
Szturm, T.2
Moussavi, Z.K.3
Nett, C.4
|