메뉴 건너뛰기




Volumn 64, Issue 1-2, 2009, Pages 101-108

Mercury selective membrane electrode based on dithio derivatized macrotricyclic compound

Author keywords

Cryptand; Hg2+; Ion selective electrode; Potentiometry; PVC membrane

Indexed keywords


EID: 67349102742     PISSN: 09230750     EISSN: None     Source Type: Journal    
DOI: 10.1007/s10847-009-9541-x     Document Type: Article
Times cited : (14)

References (36)
  • 1
    • 0347988334 scopus 로고    scopus 로고
    • Approaches to improvement of metal ion selectivity by cryptands
    • DOI 10.1016/S0010-8545(98)00050-2
    • XX Zhang RM Izatt JS Bradshaw KE Karkowiak 1998 Approaches to improvement of metal ion selectivity by cryptands Coord. Chem. Rev. 174 179 185 10.1016/S0010-8545(98)00050-2 (Pubitemid 128156867)
    • (1998) Coordination Chemistry Reviews , vol.174 , pp. 179-190
    • Zhang, X.X.1    Izatt, R.M.2    Bradshaw, J.S.3    Krakowiak, K.E.4
  • 2
    • 0001457281 scopus 로고    scopus 로고
    • Lead selective membrane electrode using cryptand (222) neutral carrier
    • 10.1007/s002160051415
    • MK Amini M Mazloum AA Ensafi 1999 Lead selective membrane electrode using cryptand (222) neutral carrier Fresenius J. Anal. Chem. 364 690 693 10.1007/s002160051415
    • (1999) Fresenius J. Anal. Chem. , vol.364 , pp. 690-693
    • Amini, M.K.1    Mazloum, M.2    Ensafi, A.A.3
  • 4
    • 14544274115 scopus 로고    scopus 로고
    • Ardakani, Nasirizadeh, N., Safari, J.: Lead-selective poly(vinyl chloride) membrane electrode based on 1-phenyl-2-(2-quinolyl)-1, 2-dioxo-2-(4-bromo) phenylhydrazone
    • HR Zare M Mazloum 2005 Ardakani, Nasirizadeh, N., Safari, J.: Lead-selective poly(vinyl chloride) membrane electrode based on 1-phenyl-2-(2-quinolyl)-1, 2-dioxo-2-(4-bromo) phenylhydrazone Bull. Korean Chem. Soc. 26 51 56
    • (2005) Bull. Korean Chem. Soc. , vol.26 , pp. 51-56
    • Zare, H.R.1    Mazloum, M.2
  • 6
    • 0001626956 scopus 로고    scopus 로고
    • Cu (II)-selective membrane electrode based on a recently synthesized macrocyclic diamide
    • 10.1006/mchj.1999.1784
    • M Shamsipur S Rouhani MR Ganjali H Eshghi H Sharghi 1999 Cu (II)-selective membrane electrode based on a recently synthesized macrocyclic diamide Microchem. J. 63 202 210 10.1006/mchj.1999.1784
    • (1999) Microchem. J. , vol.63 , pp. 202-210
    • Shamsipur, M.1    Rouhani, S.2    Ganjali, M.R.3    Eshghi, H.4    Sharghi, H.5
  • 7
    • 0033321955 scopus 로고    scopus 로고
    • Zinc-selective membrane potentiometric sensor based on a recently synthesized benzo-substituted macrocyclic diamide
    • DOI 10.1016/S0925-4005(99)00160-4
    • M Shamsipur S Rouhani MR Ganjali H Sharghi H Eshghi 1999 Zinc-selective membrane potentiometric sensor based on a recently synthesized benzo-substituted macrocyclic diamide Sens. Actuators B Chem. 59 30 34 10.1016/S0925-4005(99) 00160-4 (Pubitemid 30514417)
    • (1999) Sensors and Actuators, B: Chemical , vol.59 , Issue.1 , pp. 30-34
    • Shamsipur, M.1    Rouhani, S.2    Ganjali, M.R.3    Sharghi, H.4    Eshghi, H.5
  • 8
    • 0002370335 scopus 로고    scopus 로고
    • Mercury (II) ion-selective electrode based on dibenzo-diazathia-18-crown- 6-dione
    • 10.1002/(SICI)1521-4109(199902)11:2<81::AID-ELAN81>3.0.CO;2-Q
    • M Javanbakht MR Ganjali H Eshghi H Sharghi M Shamsipur 1999 Mercury (II) ion-selective electrode based on dibenzo-diazathia-18-crown-6-dione Electroanalysis 11 81 84 10.1002/(SICI)1521-4109(199902)11:2<81::AID- ELAN81>3.0.CO;2-Q
    • (1999) Electroanalysis , vol.11 , pp. 81-84
    • Javanbakht, M.1    Ganjali, M.R.2    Eshghi, H.3    Sharghi, H.4    Shamsipur, M.5
  • 9
    • 0036305205 scopus 로고    scopus 로고
    • Cobalt (II)-selective coated graphite PVC-membrane electrode based on a recently synthesized dibenzopyridino-substituted macrocyclicdiamide
    • 10.1002/1521-4109(200206)14:11<729::AID-ELAN729>3.0.CO;2-6
    • M Shamsipur S Rouhani T Poursaberi MR Ganjali H Sharghi K Niknam 2002 Cobalt (II)-selective coated graphite PVC-membrane electrode based on a recently synthesized dibenzopyridino-substituted macrocyclicdiamide Electroanalysis 14 729 10.1002/1521-4109(200206)14:11<729::AID-ELAN729>3.0.CO;2-6
    • (2002) Electroanalysis , vol.14 , pp. 729
    • Shamsipur, M.1    Rouhani, S.2    Poursaberi, T.3    Ganjali, M.R.4    Sharghi, H.5    Niknam, K.6
  • 10
    • 0037138251 scopus 로고    scopus 로고
    • A new PVC membrane electrode based on a thia-substituted macrocyclic diamide for selective potentiometric determination of silver ion
    • M Shamsipur SY Kazemi K Niknam HA Sharghi 2002 A new PVC membrane electrode based on a thia-substituted macrocyclic diamide for selective potentiometric determination of silver ion Bull. Korean Chem. Soc. 23 53 58
    • (2002) Bull. Korean Chem. Soc. , vol.23 , pp. 53-58
    • Shamsipur, M.1    Kazemi, S.Y.2    Niknam, K.3    Sharghi, H.A.4
  • 13
    • 33646099376 scopus 로고    scopus 로고
    • Mercury (II) ion-selective electrode based on N, N-Dimethylformamide- salicylacylhydrazone as a neutral Carrier
    • 10.2116/analsci.22.579
    • YE Guangrong Y Chai R Yuan J Daia 2006 Mercury (II) ion-selective electrode based on N, N-Dimethylformamide-salicylacylhydrazone as a neutral Carrier Anal. Sci. 22 579 582 10.2116/analsci.22.579
    • (2006) Anal. Sci. , vol.22 , pp. 579-582
    • Guangrong, Y.E.1    Chai, Y.2    Yuan, R.3    Daia, J.4
  • 14
    • 33846308134 scopus 로고    scopus 로고
    • 4-(4-Methoxybenzilidenimin) thiophenole as neutral carrier for construction of highly mercury selective electrode
    • M Ghaedi A Shokrollahi M Montazerzohori S Gharaghani 2006 4-(4-Methoxybenzilidenimin) thiophenole as neutral carrier for construction of highly mercury selective electrode Acta Chim. Slov. 53 428 436
    • (2006) Acta Chim. Slov. , vol.53 , pp. 428-436
    • Ghaedi, M.1    Shokrollahi, A.2    Montazerzohori, M.3    Gharaghani, S.4
  • 15
    • 0033792016 scopus 로고    scopus 로고
    • Mercury (II) ion-selective electrode. study of 1, 3-diphenylthiourea as ionophore
    • 10.1039/b003502p
    • ML Perez E Otazo G Macedo AP Perez JA Chamaro VH Lopez 2000 Mercury (II) ion-selective electrode. study of 1, 3-diphenylthiourea as ionophore Analyst (Lond.) 125 1787 1790 10.1039/b003502p
    • (2000) Analyst (Lond.) , vol.125 , pp. 1787-1790
    • Perez, M.L.1    Otazo, E.2    MacEdo, G.3    Perez, A.P.4    Chamaro, J.A.5    Lopez, V.H.6
  • 16
    • 33745173847 scopus 로고    scopus 로고
    • Mercury (II) ion-selective polymeric membrane sensors for analysis of mercury in hazardous wastes
    • 10.2116/analsci.22.877
    • SSM Hassan WH Mahmoud AHK Mohamed AE Kelany 2006 Mercury (II) ion-selective polymeric membrane sensors for analysis of mercury in hazardous wastes Anal. Sci. 22 877 881 10.2116/analsci.22.877
    • (2006) Anal. Sci. , vol.22 , pp. 877-881
    • Hassan, S.S.M.1    Mahmoud, W.H.2    Mohamed, A.H.K.3    Kelany, A.E.4
  • 17
    • 33745959605 scopus 로고    scopus 로고
    • Copper selective electrode based on 1, 8-bis (2-Hydroxynaphthaldiminato) 3, 6-dioxaoctane
    • MM Ardakani SH Mirhoseini MS Niasari 2006 Copper selective electrode based on 1, 8-bis (2-Hydroxynaphthaldiminato) 3, 6-dioxaoctane Acta Chim. Slov 53 197 203
    • (2006) Acta Chim. Slov , vol.53 , pp. 197-203
    • Ardakani, M.M.1    Mirhoseini, S.H.2    Niasari, M.S.3
  • 18
    • 0033818534 scopus 로고    scopus 로고
    • Highly sensitive ion-selective electrodes based on dithiacrown ethers for the determination of mercury in fish samples
    • AL Shabanov A Khandar I Mamedov AM Babazade SS Sultanzade 2000 Highly sensitive ion-selective electrodes based on dithiacrown ethers for the determination of mercury in fish samples Jomvlal Anah'tk Chemisto 55 466 468
    • (2000) Jomvlal anah'Tk Chemisto , vol.55 , pp. 466-468
    • Shabanov, A.L.1    Khandar, A.2    Mamedov, I.3    Babazade, A.M.4    Sultanzade, S.S.5
  • 19
    • 0346159229 scopus 로고    scopus 로고
    • Azothia- and azoxythiacrown ethers as ion carriers. Part I. Cationic response of membrane electrodes
    • DOI 10.1023/A:1011153809721
    • K Wygladacz E Malinowska JS Tao JF Biernat 2001 Azothia and azoxythiacrown ethers as ion carriers. Cationic response of membrane electrodes J. Incl. Phenom. Macrocycl. Chem. 39 303 307 10.1023/A:1011153809721 (Pubitemid 33654913)
    • (2001) Journal of Inclusion Phenomena , vol.39 , Issue.3-4 , pp. 303-307
    • Wygladacz, K.1    Malinowska, E.2    Szczygelska-Tao, J.3    Biernat, J.F.4
  • 21
    • 34948855395 scopus 로고    scopus 로고
    • Abd El-Aziz, M.H.: PVC-membrane electrodes based on 18-Crown-6 and dibenzo-18-crown-6 ethers for determination of silver
    • MM Zareh MA Akl AK Gohneim 2007 Abd El-Aziz, M.H.: PVC-membrane electrodes based on 18-Crown-6 and dibenzo-18-crown-6 ethers for determination of silver Turk. J. Chem. 31 449 456
    • (2007) Turk. J. Chem. , vol.31 , pp. 449-456
    • Zareh, M.M.1    Akl, M.A.2    Gohneim, A.K.3
  • 22
    • 0029424165 scopus 로고
    • Extraction spectrophotometric determination of mercury(II) using thiacrown ethers and bromocresol green
    • 10.1016/0039-9140(95)01514-C
    • B Saad SM Sultan 1995 Extraction spectrophotometric determination of mercury(II) using thiacrown ethers and bromocresol green Talanta 42 1349 1354 10.1016/0039-9140(95)01514-C
    • (1995) Talanta , vol.42 , pp. 1349-1354
    • Saad, B.1    Sultan, S.M.2
  • 23
    • 3042524590 scopus 로고    scopus 로고
    • Epinephrine-selective electrode based on lipophilic 1, 3-Bisbridged cofacial-calix[6]crown-5-ether
    • H Yeo HK Lee KC Nam S Jeon 2004 Epinephrine-selective electrode based on lipophilic 1, 3-Bisbridged cofacial-calix[6]crown-5-ether Bull. Korean Chem. Soc. 25 361 364
    • (2004) Bull. Korean Chem. Soc. , vol.25 , pp. 361-364
    • Yeo, H.1    Lee, H.K.2    Nam, K.C.3    Jeon, S.4
  • 24
    • 0004525142 scopus 로고    scopus 로고
    • Polymeric membrane sodium ion-selective electrodes based on calix[4]arene triesters
    • YD Kim H Jeong SO Kang KC Nam S Jeon 2001 Polymeric membrane sodium ion-selective electrodes based on calix[4]arene triesters Bull. Korean Chem. Soc 22 405 408
    • (2001) Bull. Korean Chem. Soc , vol.22 , pp. 405-408
    • Kim, Y.D.1    Jeong, H.2    Kang, S.O.3    Nam, K.C.4    Jeon, S.5
  • 26
    • 0040907526 scopus 로고    scopus 로고
    • Kazakova, Budnikov, H. C.: Calix[4]resorcinarene ionophore in the ion-selective electrodes with plasticized poly(vinylchloride)membranes
    • 10.1023/A:1008175805527
    • LA Muslinkina A Gennady E Evtugyn 1999 Kazakova, Budnikov, H. C.: calix[4]resorcinarene ionophore in the ion-selective electrodes with plasticized poly(vinylchloride)membranes J. Incl. Phenom. Macrocycl. Chem. 35 361 367 10.1023/A:1008175805527
    • (1999) J. Incl. Phenom. Macrocycl. Chem. , vol.35 , pp. 361-367
    • Muslinkina, L.A.1    Gennady, A.2    Evtugyn, E.3
  • 27
    • 34548512476 scopus 로고    scopus 로고
    • Potentiometric responses of ion-selective electrodes doped with diureidocalix[4]arene towards un-dissociated benzoic acid
    • 10.3390/s7081655
    • A Krajewska P Lhotak H Radecka 2007 Potentiometric responses of ion-selective electrodes doped with diureidocalix[4]arene towards un-dissociated benzoic acid Sensors 7 1655 1666 10.3390/s7081655
    • (2007) Sensors , vol.7 , pp. 1655-1666
    • Krajewska, A.1    Lhotak, P.2    Radecka, H.3
  • 28
    • 4944232102 scopus 로고    scopus 로고
    • Sensor for silver(I) ion based on schiff-base-p-tert-butylcalix[4]arene
    • RK Mahajan K Inderpreet V Sharma M Kumar 2002 Sensor for silver(I) ion based on Schiff-base -p- tertbutyl calix [4] arene Sensors 2 417 423 10.3390/s21000417 (Pubitemid 40643483)
    • (2002) Sensors , vol.2 , Issue.10 , pp. 417-423
    • Mahajan, R.K.1    Kaur, I.2    Sharma, V.3    Kumar, M.4
  • 29
    • 18444369974 scopus 로고    scopus 로고
    • Strontium (II)-selective potentiometric sensor based on ester derivative of 4-tert-butylcalix(8)arene in PVC matrix
    • AK Jain VK Gupta JR Raisoni 2004 Strontium (II)-selective potentiometric sensor based on ester derivative of 4-tert-butylcalix(8)arene in PVC matrix Sensors 4 115 124 10.3390/s40800115 (Pubitemid 40643572)
    • (2004) Sensors , vol.4 , Issue.8 , pp. 115-124
    • Jain, A.K.1    Gupta, V.K.2    Raisoni, J.R.3
  • 30
    • 22744456393 scopus 로고    scopus 로고
    • Development of a new copper (II) ion-selective poly (vinyl chloride) membrane electrode based on 2-mercaptobenzoxazole
    • M Akhond M Ghaedi J Tashkhourian 2005 Development of a new copper (II) ion-selective poly (vinyl chloride) membrane electrode based on 2-mercaptobenzoxazole Bull. Korean Chem. Soc. 26 882 886
    • (2005) Bull. Korean Chem. Soc. , vol.26 , pp. 882-886
    • Akhond, M.1    Ghaedi, M.2    Tashkhourian, J.3
  • 31
    • 0033388425 scopus 로고    scopus 로고
    • Voltammetric study of the transfer of heavy metal ions at nitrobenzene/water interface assisted by 1, 4, 7, 10, 13, 16,-hexathiacyclo octadecane
    • 10.2116/analsci.15.1179
    • H Katano M Senda 1999 Voltammetric study of the transfer of heavy metal ions at nitrobenzene/water interface assisted by 1, 4, 7, 10, 13, 16,-hexathiacyclo octadecane Anal. Sci. 15 1179 1184 10.2116/analsci.15.1179
    • (1999) Anal. Sci. , vol.15 , pp. 1179-1184
    • Katano, H.1    Senda, M.2
  • 32
    • 84876596105 scopus 로고
    • Selectivity coefficients for ion-selective electrodes recommended methods for reporting Kpot values
    • 10.1351/pac199567030507
    • Y Umezawa K Umezawa H Sato 1995 Selectivity coefficients for ion-selective electrodes recommended methods for reporting Kpot values Pure Appl. Chem. 67 507 518 10.1351/pac199567030507
    • (1995) Pure Appl. Chem. , vol.67 , pp. 507-518
    • Umezawa, Y.1    Umezawa, K.2    Sato, H.3
  • 33
    • 0038245105 scopus 로고    scopus 로고
    • Mercury (II) ion-selective polymeric membrane sensor based on a recently synthesized Schiff base
    • 10.1016/S0039-9140(03)00036-5
    • MH Mashhadizadeh I Sheikhshoaie 2003 Mercury (II) ion-selective polymeric membrane sensor based on a recently synthesized Schiff base Talanta 60 73 80 10.1016/S0039-9140(03)00036-5
    • (2003) Talanta , vol.60 , pp. 73-80
    • Mashhadizadeh, M.H.1    Sheikhshoaie, I.2
  • 34
    • 3042666534 scopus 로고    scopus 로고
    • Mercury (II) ion-selective electrodes based on p-tert-butyl calix[4]crowns with imine units
    • 10.2116/analsci.20.811
    • RK Mahajan R Kaur I Kaur V Sharma M Kumar 2004 Mercury (II) ion-selective electrodes based on p-tert-butyl calix[4]crowns with imine units Anal. Sci. 20 811 814 10.2116/analsci.20.811
    • (2004) Anal. Sci. , vol.20 , pp. 811-814
    • Mahajan, R.K.1    Kaur, R.2    Kaur, I.3    Sharma, V.4    Kumar, M.5
  • 35
    • 18844399095 scopus 로고    scopus 로고
    • A highly selective mercury electrode based on a diamine donor ligand
    • 10.1016/j.talanta.2004.11.028
    • VK Gupta S Chandra H Lang 2005 A highly selective mercury electrode based on a diamine donor ligand Talanta 66 575 580 10.1016/j.talanta.2004.11.028
    • (2005) Talanta , vol.66 , pp. 575-580
    • Gupta, V.K.1    Chandra, S.2    Lang, H.3
  • 36
    • 38349190231 scopus 로고    scopus 로고
    • Mercury-selective membrane electrode based on methyl substituted di benzo tetraaza macrocycle
    • 10.1007/s10847-007-9344-x
    • AK Singh RP Singh S Mehtab 2008 Mercury-selective membrane electrode based on methyl substituted di benzo tetraaza macrocycle J. Incl. Phenom. Macrocycl. Chem. 60 9 15 10.1007/s10847-007-9344-x
    • (2008) J. Incl. Phenom. Macrocycl. Chem. , vol.60 , pp. 9-15
    • Singh, A.K.1    Singh, R.P.2    Mehtab, S.3