Volumn 13, Issue 3, 2009, Pages 483-493

Congenital aortic disease: 4D magnetic resonance segmentation and quantitative analysis

Author keywords

Aortic aneurysm; Aortic MR Images; Computer aided diagnosis (CAD); Congenital heart disease; Level set; Optimal surface segmentation; Principal component analysis (PCA); Support Vector Machine (SVM)

Indexed keywords

AORTIC ANEURYSM; AORTIC MR IMAGES; COMPUTER-AIDED DIAGNOSIS (CAD); CONGENITAL HEART DISEASE; LEVEL-SET; OPTIMAL SURFACE SEGMENTATION; SUPPORT VECTOR MACHINE (SVM);

EID: 67349101996     PISSN: 13618415     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.media.2009.02.005     Document Type: Article
Times cited : (53)

References (37)
  • 1
    • 0017367516 scopus 로고
    • Echocardiographic manifestation of annuloaortic ectasia: its paradoxical motion of the aorta and premature systolic closure of the aortic valve
    • Atsuchi Y., Nagai Y., Komatsu Y., Nakamura K., Shibuya M., and Hirosawa K. Echocardiographic manifestation of annuloaortic ectasia: its paradoxical motion of the aorta and premature systolic closure of the aortic valve. American Heart Journal 93 (1977) 428-433
    • (1977) American Heart Journal , vol.93 , pp. 428-433
    • Atsuchi, Y.1    Nagai, Y.2    Komatsu, Y.3    Nakamura, K.4    Shibuya, M.5    Hirosawa, K.6
  • 2
    • 0030153643 scopus 로고    scopus 로고
    • Tracking and motion analysis of the left ventricle with deformable superquadrics
    • Bardinet E., Cohen L., and Ayache N. Tracking and motion analysis of the left ventricle with deformable superquadrics. Medical Image Analysis 1 2 (1996) 129-149
    • (1996) Medical Image Analysis , vol.1 , Issue.2 , pp. 129-149
    • Bardinet, E.1    Cohen, L.2    Ayache, N.3
  • 3
    • 0042767034 scopus 로고    scopus 로고
    • Robust segmentation of tubular structures in 3D medical images by parametric object detection and tracking
    • Behrens T., Rohr K., and Stiehl H. Robust segmentation of tubular structures in 3D medical images by parametric object detection and tracking. IEEE Transactions on Systems Man and Cybernetics 33 4 (2003) 554-561
    • (2003) IEEE Transactions on Systems Man and Cybernetics , vol.33 , Issue.4 , pp. 554-561
    • Behrens, T.1    Rohr, K.2    Stiehl, H.3
  • 6
    • 21144442182 scopus 로고    scopus 로고
    • Construction of a statistical model for cardiac motion analysis using nonrigid image registration
    • Proceedings of Information Processing in Medical Imaging IPMI, Springer-Verlag, pp
    • Chandrashekara, R., Rao, A., Sanchez-Ortiz, G.I., Mohiaddin, R.H., Rueckert, D., 2003. Construction of a statistical model for cardiac motion analysis using nonrigid image registration. In: Proceedings of Information Processing in Medical Imaging (IPMI), LNCS, vol. 2878. Springer-Verlag, pp. 599-610.
    • (2003) LNCS , vol.2878 , pp. 599-610
    • Chandrashekara, R.1    Rao, A.2    Sanchez-Ortiz, G.I.3    Mohiaddin, R.H.4    Rueckert, D.5
  • 8
    • 33646053821 scopus 로고    scopus 로고
    • Decreased aortic root distensibility rather than increased aortic root diameter as an important cardiovascular risk factor in the Marfan syndrome
    • Cheng T.O. Decreased aortic root distensibility rather than increased aortic root diameter as an important cardiovascular risk factor in the Marfan syndrome. The American Journal of Cardiology 97 (2006) 1422
    • (2006) The American Journal of Cardiology , vol.97 , pp. 1422
    • Cheng, T.O.1
  • 9
    • 34249753618 scopus 로고
    • Support-vector networks
    • Cortes C., and Vapnik V. Support-vector networks. Machine Learning 20 3 (1995) 273-297
    • (1995) Machine Learning , vol.20 , Issue.3 , pp. 273-297
    • Cortes, C.1    Vapnik, V.2
  • 11
    • 21144434898 scopus 로고    scopus 로고
    • Adapting active shape models for 3D segmentation of tubular structures in medical images
    • Proceedings of Information Processing in Medical Imaging IPMI, Springer-Verlag, pp
    • de Bruijne, M., van Ginneken, B., Viergever, M.A., Niessen, W.J., 2003. Adapting active shape models for 3D segmentation of tubular structures in medical images. In: Proceedings of Information Processing in Medical Imaging (IPMI), LNCS, vol. 2732. Springer-Verlag, pp. 136-147.
    • (2003) LNCS , vol.2732 , pp. 136-147
    • de Bruijne, M.1    van Ginneken, B.2    Viergever, M.A.3    Niessen, W.J.4
  • 12
    • 65549089797 scopus 로고    scopus 로고
    • Multiscale vessel enhancement filtering
    • Proceedings of Medical Image Computing and Computer Assisted Intervention MICCAI, Germany: Springer-Verlag, pp
    • Frangi, A., Niessen, W., Vincken, K., Viergever, M., 1998. Multiscale vessel enhancement filtering. In: Proceedings of Medical Image Computing and Computer Assisted Intervention (MICCAI), LNCS, vol. 1496. Germany: Springer-Verlag, pp. 130-137.
    • (1998) LNCS , vol.1496 , pp. 130-137
    • Frangi, A.1    Niessen, W.2    Vincken, K.3    Viergever, M.4
  • 13
    • 0036770220 scopus 로고    scopus 로고
    • Automatic construction of multiple-object three-dimensional statistical shape models: Application to cardiac modelling
    • Frangi A., Rueckert D., Schnabel J., and Niessen W. Automatic construction of multiple-object three-dimensional statistical shape models: Application to cardiac modelling. IEEE Transactions on Medical Imaging 21 (2002) 1151-1166
    • (2002) IEEE Transactions on Medical Imaging , vol.21 , pp. 1151-1166
    • Frangi, A.1    Rueckert, D.2    Schnabel, J.3    Niessen, W.4
  • 20
    • 0032316532 scopus 로고    scopus 로고
    • A real-time algorithm for medical shape recovery
    • Narosa Publishing House
    • Malladi R., and Sethian J.A. A real-time algorithm for medical shape recovery. Proc. of ICCV (1998), Narosa Publishing House 304-310
    • (1998) Proc. of ICCV , pp. 304-310
    • Malladi, R.1    Sethian, J.A.2
  • 21
    • 0028919981 scopus 로고
    • A dynamic finite element surface model for segmentation and tracking in multidimensional medical images with application to cardiac 4D image analysis
    • McInerney T., and Terzopoulos D. A dynamic finite element surface model for segmentation and tracking in multidimensional medical images with application to cardiac 4D image analysis. Computerized Medical Imaging and Graphics 19 1 (1995) 69-83
    • (1995) Computerized Medical Imaging and Graphics , vol.19 , Issue.1 , pp. 69-83
    • McInerney, T.1    Terzopoulos, D.2
  • 22
    • 10844239822 scopus 로고    scopus 로고
    • 4D deformable models with temporal constraints: application to 4D cardiac image segmentation
    • Montagnat J., and Delingette H. 4D deformable models with temporal constraints: application to 4D cardiac image segmentation. Medical Image Analysis 9 1 (2005) 87-100
    • (2005) Medical Image Analysis , vol.9 , Issue.1 , pp. 87-100
    • Montagnat, J.1    Delingette, H.2
  • 23
    • 29144477913 scopus 로고    scopus 로고
    • Quantitative analysis of intrathoracic airway trees: Methods and validation
    • Proc. of IPMI, Springer-Verlag
    • Palagyi K., Tschirren J., and Sonka M. Quantitative analysis of intrathoracic airway trees: Methods and validation. Proc. of IPMI. LNCS vol. 2732 (2003), Springer-Verlag 222-233
    • (2003) LNCS , vol.2732 , pp. 222-233
    • Palagyi, K.1    Tschirren, J.2    Sonka, M.3
  • 25
    • 0141905236 scopus 로고    scopus 로고
    • A novel Doppler echocardiographic method of measuring the biophysical properties of the aorta in pediatric patients
    • Sandor G.G., Hishitani T., Petty R.E., Potts M.T., Desouza A., Desouza E., and Potts J.E. A novel Doppler echocardiographic method of measuring the biophysical properties of the aorta in pediatric patients. J Am Soc Echocardiogr 16 (2003) 745-750
    • (2003) J Am Soc Echocardiogr , vol.16 , pp. 745-750
    • Sandor, G.G.1    Hishitani, T.2    Petty, R.E.3    Potts, M.T.4    Desouza, A.5    Desouza, E.6    Potts, J.E.7
  • 27
    • 0031060806 scopus 로고    scopus 로고
    • Adaptive approach to accurate analysis of small diameter vessels in cineangiograms
    • Sonka M., Reddy G., and Collins S.M. Adaptive approach to accurate analysis of small diameter vessels in cineangiograms. IEEE Trans. Med. Imag. 16 1 (1997) 87-95
    • (1997) IEEE Trans. Med. Imag. , vol.16 , Issue.1 , pp. 87-95
    • Sonka, M.1    Reddy, G.2    Collins, S.M.3
  • 30
    • 67349113861 scopus 로고    scopus 로고
    • The Centers for Disease Control and Prevention (CDC), 2006. http://www.cdc.gov/.
    • (2006)
  • 33
    • 0027542457 scopus 로고
    • B-spline signal processing: Part II - efficient design and applications
    • Unser M., Aldroubi A., and Eden M. B-spline signal processing: Part II - efficient design and applications. IEEE Transactions on Signal Processing 41 (1993) 834-848
    • (1993) IEEE Transactions on Signal Processing , vol.41 , pp. 834-848
    • Unser, M.1    Aldroubi, A.2    Eden, M.3
  • 35
    • 84869153087 scopus 로고    scopus 로고
    • Optimal net surface problems with applications
    • Proc. of ICALP, Springer-Verlag
    • Wu X., and Chen D.Z. Optimal net surface problems with applications. Proc. of ICALP. LNCS vol. 2380 (2002), Springer-Verlag 1029-1042
    • (2002) LNCS , vol.2380 , pp. 1029-1042
    • Wu, X.1    Chen, D.Z.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.