메뉴 건너뛰기




Volumn 58, Issue 5, 2009, Pages 1427-1435

Metrological characterization and operating principle identification of static meters for reactive energy: An experimental approach under nonsinusoidal test conditions

Author keywords

Energy measurements; Harmonic distortion; Power quality; Power systems; Static meters

Indexed keywords

ACCURACY CLASS; ACCURACY TESTS; ENERGY MEASUREMENTS; EXPERIMENTAL APPROACHES; EXPERIMENTAL TESTS; METROLOGICAL CHARACTERIZATIONS; NON-SINUSOIDAL; NONSINUSOIDAL CONDITIONS; OPERATING PRINCIPLES; POWER SYSTEMS; STATIC METERS; TEST CONDITIONS;

EID: 67349095029     PISSN: 00189456     EISSN: None     Source Type: Journal    
DOI: 10.1109/TIM.2008.2009134     Document Type: Conference Paper
Times cited : (33)

References (15)
  • 1
    • 47149106041 scopus 로고    scopus 로고
    • The measurement of reactive energy in polluted distribution power systems: Analysis of the performance of commercial static meters
    • Jul
    • A. Cataliotti, V. Cosentino, and S. Nuccio, "The measurement of reactive energy in polluted distribution power systems: Analysis of the performance of commercial static meters," IEEE Trans. Power Del., vol. 23, no. 3, pp. 1296-1301, Jul. 2008.
    • (2008) IEEE Trans. Power Del , vol.23 , Issue.3 , pp. 1296-1301
    • Cataliotti, A.1    Cosentino, V.2    Nuccio, S.3
  • 2
    • 34648833317 scopus 로고    scopus 로고
    • The metrological characterization of the static meters for reactive energy in the presence of harmonic distortion
    • Warsaw, Poland, May 1-3
    • A. Cataliotti, V. Cosentino, and S. Nuccio, "The metrological characterization of the static meters for reactive energy in the presence of harmonic distortion," in Proc. IMTC, Warsaw, Poland, May 1-3, 2007, pp. 1-6.
    • (2007) Proc. IMTC , pp. 1-6
    • Cataliotti, A.1    Cosentino, V.2    Nuccio, S.3
  • 3
    • 51349113051 scopus 로고    scopus 로고
    • An harmonic test condition for the metrological characterization and the operating principle identification of reactive static meters
    • Victoria, BC, Canada, May 12-15
    • A. Cataliotti, V. Cosentino, A. Lipari, and S. Nuccio, "An harmonic test condition for the metrological characterization and the operating principle identification of reactive static meters," in Proc. IEEE Int. IMTC, Victoria, BC, Canada, May 12-15, 2008, pp. 1269-1273.
    • (2008) Proc. IEEE Int. IMTC , pp. 1269-1273
    • Cataliotti, A.1    Cosentino, V.2    Lipari, A.3    Nuccio, S.4
  • 4
    • 0026939752 scopus 로고
    • Evaluation of reactive power meters in the presence of high harmonic distortion
    • Oct
    • P. S. Filipski and P. W. Labaj, "Evaluation of reactive power meters in the presence of high harmonic distortion," IEEE Trans. Power Del. vol. 7, no. 4, pp. 1793-1799, Oct. 1992.
    • (1992) IEEE Trans. Power Del , vol.7 , Issue.4 , pp. 1793-1799
    • Filipski, P.S.1    Labaj, P.W.2
  • 5
    • 0025507174 scopus 로고
    • Induction varhour and solid-state varhour meters performance on nonlinear loads
    • Nov
    • M. D. Cox and T. B. Williams, "Induction varhour and solid-state varhour meters performance on nonlinear loads," IEEE Trans. Power Del., vol. 5, no. 4, pp. 1678-1686, Nov. 1990.
    • (1990) IEEE Trans. Power Del , vol.5 , Issue.4 , pp. 1678-1686
    • Cox, M.D.1    Williams, T.B.2
  • 6
    • 34748853705 scopus 로고    scopus 로고
    • A new methodological approach to quality assurance of energy meters under nonsinusoidal conditions
    • Oct
    • D. Gallo, C. Landi, N. Pasquino, and N. Polese, "A new methodological approach to quality assurance of energy meters under nonsinusoidal conditions," IEEE Trans. Instrum. Meas., vol. 56, no. 5, pp. 1694-1702, Oct. 2007.
    • (2007) IEEE Trans. Instrum. Meas , vol.56 , Issue.5 , pp. 1694-1702
    • Gallo, D.1    Landi, C.2    Pasquino, N.3    Polese, N.4
  • 7
    • 67349144464 scopus 로고    scopus 로고
    • Electricity Metering Equipment (A.C.) - General Requirements, Tests and Test Conditions - Part 11: Metering Equipment, EN 62052-11, Nov. 2003.
    • Electricity Metering Equipment (A.C.) - General Requirements, Tests and Test Conditions - Part 11: Metering Equipment, EN 62052-11, Nov. 2003.
  • 8
    • 67349205908 scopus 로고    scopus 로고
    • Electricity Metering Equipment (A.C.) - Particular Requirements - Part 21: Static Meters for Active Energy (Class 1 and 2), EN 62053-21, Mar. 2003.
    • Electricity Metering Equipment (A.C.) - Particular Requirements - Part 21: Static Meters for Active Energy (Class 1 and 2), EN 62053-21, Mar. 2003.
  • 9
    • 67349123129 scopus 로고    scopus 로고
    • Electricity Metering Equipment (A.C.) - Particular Requirements - Part 21: Static Meters for Active Energy (Class 0, 2S and 0, 5S), EN 62053-22, Mar. 2003.
    • Electricity Metering Equipment (A.C.) - Particular Requirements - Part 21: Static Meters for Active Energy (Class 0, 2S and 0, 5S), EN 62053-22, Mar. 2003.
  • 10
    • 67349125221 scopus 로고    scopus 로고
    • Electricity Metering Equipment (A.C.) - Particular Requirements - Part 23: Static Meters for Reactive Energy (Class 2 and 3), EN 62053-23, Dec. 2003.
    • Electricity Metering Equipment (A.C.) - Particular Requirements - Part 23: Static Meters for Reactive Energy (Class 2 and 3), EN 62053-23, Dec. 2003.
  • 11
    • 47149095471 scopus 로고    scopus 로고
    • A novel approach based on nonactive powers for the identification of disturbing loads in power systems
    • Jul
    • P. V. Barbaro, A. Cataliotti, V. Cosentino, and S. Nuccio, "A novel approach based on nonactive powers for the identification of disturbing loads in power systems," IEEE Trans. Power Del., vol. 22, no. 3, pp. 1782-1789, Jul. 2007.
    • (2007) IEEE Trans. Power Del , vol.22 , Issue.3 , pp. 1782-1789
    • Barbaro, P.V.1    Cataliotti, A.2    Cosentino, V.3    Nuccio, S.4
  • 12
    • 52349104823 scopus 로고
    • Powers in nonsinusoidal situation: A review of definitions and physical meaning
    • Jul
    • A. E. Emanuel, "Powers in nonsinusoidal situation: A review of definitions and physical meaning," IEEE Trans. Power Del., vol. 5, no. 3, pp. 1377-1389, Jul. 1990.
    • (1990) IEEE Trans. Power Del , vol.5 , Issue.3 , pp. 1377-1389
    • Emanuel, A.E.1
  • 13
    • 0001512466 scopus 로고    scopus 로고
    • Definitions of electrical quantities commonly used in non-sinusoidal situations
    • Jul./Aug
    • A. Ferrero, "Definitions of electrical quantities commonly used in non-sinusoidal situations," Eur. Trans. Elect. Power, vol. 8, no. 4, pp. 235-240, Jul./Aug. 1998.
    • (1998) Eur. Trans. Elect. Power , vol.8 , Issue.4 , pp. 235-240
    • Ferrero, A.1
  • 14
    • 0033909039 scopus 로고    scopus 로고
    • Energy flow and power phenomena in electrical circuits: Illusions and reality
    • L. S. Czarnecki, "Energy flow and power phenomena in electrical circuits: Illusions and reality," Elect. Eng., vol. 82, no. 3/4, pp. 119-126, 2000.
    • (2000) Elect. Eng , vol.82 , Issue.3-4 , pp. 119-126
    • Czarnecki, L.S.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.