메뉴 건너뛰기




Volumn 18, Issue 3, 2009, Pages 371-378

Observations on retrieved glenoid components from total shoulder arthroplasty

Author keywords

glenoid component failure; glenoid loosening; Polyethylene wear; total shoulder arthroplasty revision

Indexed keywords

POLYETHYLENE;

EID: 67349088271     PISSN: 10582746     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jse.2008.12.006     Document Type: Article
Times cited : (35)

References (30)
  • 1
    • 0036080860 scopus 로고    scopus 로고
    • Fixation for the millennium: the shoulder
    • Bauer G.S., Murthi A.M., and Bigliani L.U. Fixation for the millennium: the shoulder. J Arthroplasty 17 4 suppl. 1 (2002) 9-10
    • (2002) J Arthroplasty , vol.17 , Issue.4 SUPPL. 1 , pp. 9-10
    • Bauer, G.S.1    Murthi, A.M.2    Bigliani, L.U.3
  • 2
    • 2342660229 scopus 로고    scopus 로고
    • Glenoid resurfacing in shoulder arthroplasty: indications and contraindications
    • Baumgarten K.M., Lashgari C.J., and Yamaguchi K. Glenoid resurfacing in shoulder arthroplasty: indications and contraindications. Instr Course Lect 53 (2004) 3-11
    • (2004) Instr Course Lect , vol.53 , pp. 3-11
    • Baumgarten, K.M.1    Lashgari, C.J.2    Yamaguchi, K.3
  • 4
    • 0036632076 scopus 로고    scopus 로고
    • Cemented polyethylene versus uncemented metal-backed glenoid components in total shoulder arthroplasty: a prospective, double-blind, randomized study
    • Boileau P., Avidor C., Krishnan S.G., Walch G., Kempf J.F., and Molé D. Cemented polyethylene versus uncemented metal-backed glenoid components in total shoulder arthroplasty: a prospective, double-blind, randomized study. J Shoulder Elbow Surg 11 (2002) 351-359
    • (2002) J Shoulder Elbow Surg , vol.11 , pp. 351-359
    • Boileau, P.1    Avidor, C.2    Krishnan, S.G.3    Walch, G.4    Kempf, J.F.5    Molé, D.6
  • 5
    • 0026710067 scopus 로고
    • Edge displacement and deformation of glenoid components in response to eccentric loading. The effect of preparation of the glenoid bone
    • Collins D., Tencer A., Sidles J., and Matsen III F. Edge displacement and deformation of glenoid components in response to eccentric loading. The effect of preparation of the glenoid bone. J Bone Joint Surg Am 74 (1992) 501-507
    • (1992) J Bone Joint Surg Am , vol.74 , pp. 501-507
    • Collins, D.1    Tencer, A.2    Sidles, J.3    Matsen III, F.4
  • 6
    • 67349269617 scopus 로고    scopus 로고
    • Risks of loosening of a prosthetic glenoid implanted in retroversion
    • Farron A., Terrier A., and Buchler P. Risks of loosening of a prosthetic glenoid implanted in retroversion. J Shoulder Elbow Surg 52 (2006) 1-6
    • (2006) J Shoulder Elbow Surg , vol.52 , pp. 1-6
    • Farron, A.1    Terrier, A.2    Buchler, P.3
  • 7
    • 38649105823 scopus 로고    scopus 로고
    • Influence of component positioning on impingement in conventional total shoulder arthroplasty
    • Favre P., Moor B., Snedeker J.G., and Gerber C. Influence of component positioning on impingement in conventional total shoulder arthroplasty. Clin Biomech (Bristol, Avon) 23 (2008) 175-183
    • (2008) Clin Biomech (Bristol, Avon) , vol.23 , pp. 175-183
    • Favre, P.1    Moor, B.2    Snedeker, J.G.3    Gerber, C.4
  • 8
    • 0023879192 scopus 로고
    • Glenoid loosening in total shoulder arthroplasty. Association with rotator cuff deficiency
    • Franklin J.L., Barrett W.P., Jackins S.E., and Matsen III F.A. Glenoid loosening in total shoulder arthroplasty. Association with rotator cuff deficiency. J Arthroplasty 3 (1988) 39-46
    • (1988) J Arthroplasty , vol.3 , pp. 39-46
    • Franklin, J.L.1    Barrett, W.P.2    Jackins, S.E.3    Matsen III, F.A.4
  • 9
    • 0036157670 scopus 로고    scopus 로고
    • Retrieved glenoid components: a classification system for surface damage analysis
    • Gunther S.B., Graham J., Norris T.R., Ries M.D., and Pruitt L. Retrieved glenoid components: a classification system for surface damage analysis. J Arthroplasty 17 (2002) 95-100
    • (2002) J Arthroplasty , vol.17 , pp. 95-100
    • Gunther, S.B.1    Graham, J.2    Norris, T.R.3    Ries, M.D.4    Pruitt, L.5
  • 10
    • 0037628986 scopus 로고    scopus 로고
    • Observations on retrieved glenoid components
    • Hertel R., and Ballmer F.T. Observations on retrieved glenoid components. J Arthroplasty 18 (2003) 361-366
    • (2003) J Arthroplasty , vol.18 , pp. 361-366
    • Hertel, R.1    Ballmer, F.T.2
  • 11
    • 0020826593 scopus 로고
    • Retrieval analysis of total knee prostheses: a method and its application to 48 total condylar prostheses
    • Hood R.W., Wright T.M., and Burstein A.H. Retrieval analysis of total knee prostheses: a method and its application to 48 total condylar prostheses. J Biomed Mater Res 17 (1983) 829-842
    • (1983) J Biomed Mater Res , vol.17 , pp. 829-842
    • Hood, R.W.1    Wright, T.M.2    Burstein, A.H.3
  • 12
    • 9644262410 scopus 로고    scopus 로고
    • The effects of glenoid component alignment variations on cement mantle stresses in total shoulder arthroplasty
    • Hopkins A.R., Hansen U.N., Amis A.A., and Emery R. The effects of glenoid component alignment variations on cement mantle stresses in total shoulder arthroplasty. J Shoulder Elbow Surg 13 (2004) 668-675
    • (2004) J Shoulder Elbow Surg , vol.13 , pp. 668-675
    • Hopkins, A.R.1    Hansen, U.N.2    Amis, A.A.3    Emery, R.4
  • 14
    • 0036633021 scopus 로고    scopus 로고
    • The radiographic evaluation of keeled and pegged glenoid component insertion
    • Lazarus M.D., Jensen K.L., Southworth C., and Matsen III F.A. The radiographic evaluation of keeled and pegged glenoid component insertion. J Bone Joint Surg Am 84 (2002) 1174-1182
    • (2002) J Bone Joint Surg Am , vol.84 , pp. 1174-1182
    • Lazarus, M.D.1    Jensen, K.L.2    Southworth, C.3    Matsen III, F.A.4
  • 16
    • 12244261586 scopus 로고    scopus 로고
    • Matsen F.A., Lippitt S.B., and DeBartolo S.E. (Eds), Saunders, Philadelphia
    • In: Matsen F.A., Lippitt S.B., and DeBartolo S.E. (Eds). Shoulder surgery: principles and procedures (2004), Saunders, Philadelphia
    • (2004) Shoulder surgery: principles and procedures
  • 17
    • 0001097487 scopus 로고    scopus 로고
    • Glenohumeral arthritis and its management
    • Rockwood Jr. C.A., Matsen III F.A., Wirth M.A., and Lippitt S.B. (Eds), WB Saunders, Philadelphia
    • Matsen III F.A., Rockwood Jr. C.A., Wirth M.A., Lippitt S.B., and Parsons M. Glenohumeral arthritis and its management. In: Rockwood Jr. C.A., Matsen III F.A., Wirth M.A., and Lippitt S.B. (Eds). The shoulder. 3rd ed (2004), WB Saunders, Philadelphia 879-1008
    • (2004) The shoulder. 3rd ed , pp. 879-1008
    • Matsen III, F.A.1    Rockwood Jr., C.A.2    Wirth, M.A.3    Lippitt, S.B.4    Parsons, M.5
  • 19
    • 0001781540 scopus 로고    scopus 로고
    • Cemented glenoid component: results in osteoarthritis and rheumatoid arthritis
    • Walch G., and Boileau P. (Eds), Springer, New York
    • Molé D., Roche O., Riand N., Levigne C., and Walch G. Cemented glenoid component: results in osteoarthritis and rheumatoid arthritis. In: Walch G., and Boileau P. (Eds). Shoulder arthroplasty (1999), Springer, New York 163-171
    • (1999) Shoulder arthroplasty , pp. 163-171
    • Molé, D.1    Roche, O.2    Riand, N.3    Levigne, C.4    Walch, G.5
  • 20
    • 67349164412 scopus 로고    scopus 로고
    • National Hospital Discharge Survey, US Bureau of the Census, Accessed: Nov 20, 2008
    • National Hospital Discharge Survey, US Bureau of the Census, 2004, 2003. http://www.cdc.gov/nchs/products/pubs/pubd/series/ser.htm#sr13. Accessed: Nov 20, 2008.
    • (2003) , vol.2004
  • 21
    • 0020039416 scopus 로고
    • Recent experiences in total shoulder arthroplasty
    • Neer C.S., Watson K.C., and Stanton F.J. Recent experiences in total shoulder arthroplasty. J Bone Joint Surg Am 64 (1982) 319-337
    • (1982) J Bone Joint Surg Am , vol.64 , pp. 319-337
    • Neer, C.S.1    Watson, K.C.2    Stanton, F.J.3
  • 22
    • 0030136199 scopus 로고    scopus 로고
    • Indications for glenoid resurfacing in shoulder arthroplasty
    • Rodosky M.W., and Bigliani L.U. Indications for glenoid resurfacing in shoulder arthroplasty. J Shoulder Elbow Surg 5 (1996) 231-248
    • (1996) J Shoulder Elbow Surg , vol.5 , pp. 231-248
    • Rodosky, M.W.1    Bigliani, L.U.2
  • 23
    • 0034878494 scopus 로고    scopus 로고
    • Observations on retrieved polyethylene glenoid components
    • Scarlat M.M., and Matsen III F.A. Observations on retrieved polyethylene glenoid components. J Arthroplasty 16 (2001) 795-801
    • (2001) J Arthroplasty , vol.16 , pp. 795-801
    • Scarlat, M.M.1    Matsen III, F.A.2
  • 24
    • 34247587093 scopus 로고    scopus 로고
    • Biomechanical effects of glenoid retroversion in total shoulder arthroplasty
    • Shapiro T.A., McGarry M.H., Gupta R., Lee Y.S., and Lee T.Q. Biomechanical effects of glenoid retroversion in total shoulder arthroplasty. J Shoulder Elbow Surg 16 3 suppl (2007) S90-S95
    • (2007) J Shoulder Elbow Surg , vol.16 , Issue.3 SUPPL
    • Shapiro, T.A.1    McGarry, M.H.2    Gupta, R.3    Lee, Y.S.4    Lee, T.Q.5
  • 25
    • 20444399895 scopus 로고    scopus 로고
    • Impingement in total hip arthroplasty: a study of retrieved acetabular components
    • Shon W., Baldini T., Peterson M.G.B., Wright T., and Salvati E. Impingement in total hip arthroplasty: a study of retrieved acetabular components. J Arthroplasty 20 (2005) 427-435
    • (2005) J Arthroplasty , vol.20 , pp. 427-435
    • Shon, W.1    Baldini, T.2    Peterson, M.G.B.3    Wright, T.4    Salvati, E.5
  • 26
    • 2442608349 scopus 로고    scopus 로고
    • Sterilization and polyethylene wear: clinical studies to support laboratory data
    • Sychters C., and Orishimo K. Sterilization and polyethylene wear: clinical studies to support laboratory data. J Bone Joint Surg Am 86 (2004) 1017-1022
    • (2004) J Bone Joint Surg Am , vol.86 , pp. 1017-1022
    • Sychters, C.1    Orishimo, K.2
  • 27
    • 0031266048 scopus 로고    scopus 로고
    • Total shoulder arthroplasty with the Neer prosthesis: long-term results
    • Torchia M.E., Cofield R.H., and Settergren C.R. Total shoulder arthroplasty with the Neer prosthesis: long-term results. J Shoulder Elbow Surg 6 (1997) 495-505
    • (1997) J Shoulder Elbow Surg , vol.6 , pp. 495-505
    • Torchia, M.E.1    Cofield, R.H.2    Settergren, C.R.3
  • 28
    • 0345004140 scopus 로고    scopus 로고
    • Isolation and characterization of polyethylene wear debris associated with osteolysis following total shoulder arthroplasty
    • Wirth M.A., Agrawal C.M., Mabrey J.D., Dean D.D., Blanchard C.R., Miller M.A., et al. Isolation and characterization of polyethylene wear debris associated with osteolysis following total shoulder arthroplasty. J Bone Joint Surg Am 81 (1999) 29-37
    • (1999) J Bone Joint Surg Am , vol.81 , pp. 29-37
    • Wirth, M.A.1    Agrawal, C.M.2    Mabrey, J.D.3    Dean, D.D.4    Blanchard, C.R.5    Miller, M.A.6
  • 29
    • 0029991347 scopus 로고    scopus 로고
    • Complications of total shoulder-replacement arthroplasty
    • Wirth M.A., and Rockwood Jr. C.A. Complications of total shoulder-replacement arthroplasty. J Bone Joint Surg Am 78 (1996) 603-616
    • (1996) J Bone Joint Surg Am , vol.78 , pp. 603-616
    • Wirth, M.A.1    Rockwood Jr., C.A.2
  • 30


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.