Volumn 35, Issue 5, 2009, Pages 943-947

Intraoperative validation of a new system for invasive continuous cardiac output measurement

Author keywords

Continuous cardiac output monitoring catheter

Indexed keywords

ARTICLE; BLAND ALTMAN PLOTTING; CARDIOPULMONARY BYPASS; CLINICAL ARTICLE; CORRELATION COEFFICIENT; DEVICE; EVALUATION; FLOW MEASUREMENT; HEART OUTPUT MEASUREMENT; HEART RIGHT VENTRICLE; HEART SURGERY; HUMAN; INTRAOPERATIVE PERIOD; INVASIVE PROCEDURE; MECHANICAL PROBE; PATIENT MONITORING; PULMONARY ARTERY CATHETER; RELIABILITY; STATISTICAL ANALYSIS; STUDENT T TEST; TRANSIT TIME FLOW MEASUREMENT; VALIDATION PROCESS;

EID: 67349085229     PISSN: 03424642     EISSN: 14321238     Source Type: Journal    
DOI: 10.1007/s00134-009-1422-7     Document Type: Article
Times cited : (4)

References (9)
  • 2
    • 0026695419 scopus 로고
    • Continuous thermodilution cardiac output measurement in intensive care unit patients
    • ML Yelderman MA Ramsay MD Quinn 1992 Continuous thermodilution cardiac output measurement in intensive care unit patients J Cardiothorac Vasc Anesth 6 270 274
    • (1992) J Cardiothorac Vasc Anesth , vol.6 , pp. 270-274
    • Yelderman, M.L.1    Ramsay, M.A.2    Quinn, M.D.3
  • 3
    • 0029016594 scopus 로고
    • Evaluation of a new continuous thermodilution cardiac output monitor in critically ill patients: A prospective criterion standard study
    • M Haller C Zöllner J Briegel H Forst 1995 Evaluation of a new continuous thermodilution cardiac output monitor in critically ill patients: a prospective criterion standard study Crit Care Med 23 860 866
    • (1995) Crit Care Med , vol.23 , pp. 860-866
    • Haller, M.1    Zöllner, C.2    Briegel, J.3    Forst, H.4
  • 4
    • 0027938298 scopus 로고
    • Is continuous cardiac output measurement using thermodilution reliable in the critically ill patient?
    • J Boldt T Menges M Wollbrück 1994 Is continuous cardiac output measurement using thermodilution reliable in the critically ill patient? Crit Care Med 22 1913 1918 (Pubitemid 24375091)
    • (1994) Critical Care Medicine , vol.22 , Issue.12 , pp. 1913-1918
    • Boldt, J.1    Menges, T.2    Wollbruck, M.3    Hammermann, H.4    Hempelmann, G.5
  • 5
    • 0029807410 scopus 로고    scopus 로고
    • Analysis of the accuracy of continuous thermodilution cardiac output measurement
    • L Jacquet G Hanique D Glorieux 1996 Analysis of the accuracy of continuous thermodilution cardiac output measurement Intensive Care Med 22 1125 1129
    • (1996) Intensive Care Med , vol.22 , pp. 1125-1129
    • Jacquet, L.1    Hanique, G.2    Glorieux, D.3
  • 7
    • 1542709739 scopus 로고    scopus 로고
    • Original insight into continuous cardiac output monitoring: «truCCOMS» - Correlation with other methods
    • G Padua G Canestrelli G Pala D Sechi MC Spanu 2003 Original insight into continuous cardiac output monitoring: "TruCCOMS". Correlation with other methods Minerva Anestesiol 69 617 624 (Pubitemid 41739231)
    • (2003) Minerva Anestesiologica , vol.69 , Issue.7-8 , pp. 617-624
    • Padua, G.1    Canestrelli, G.2    Pala, G.3    Sechi, D.4    Spanu, M.C.5
  • 9
    • 0033003166 scopus 로고    scopus 로고
    • A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques
    • DOI 10.1023/A:1009982611386
    • LAH Critchley JAJH Critchley 1999 A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques J Clin Monit Comput 15 85 91 (Pubitemid 29278438)
    • (1999) Journal of Clinical Monitoring and Computing , vol.15 , Issue.2 , pp. 85-91
    • Critchley, L.A.H.1    Critchley, J.A.J.H.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.