메뉴 건너뛰기




Volumn 16, Issue 2, 2009, Pages 178-188

Clinical significance and technical assessment of stent cell geometry in carotid artery stenting

Author keywords

Carotid artery; Distal protection; Emboli; Plaque; Shape memory alloy; Stenosis; Stent; Thrombosis

Indexed keywords

TISSUE SCAFFOLD;

EID: 67249128256     PISSN: 15266028     EISSN: None     Source Type: Journal    
DOI: 10.1583/08-2583.1     Document Type: Review
Times cited : (25)

References (22)
  • 2
    • 12144266859 scopus 로고    scopus 로고
    • Intravascular stents in the last and the next 10 years
    • Palmaz JC. Intravascular stents in the last and the next 10 years. J Endovasc Ther. 2004;11(Suppl II):II-200-II-206. (Pubitemid 40109538)
    • (2004) Journal of Endovascular Therapy , vol.11 , Issue.SUPPL. 2
    • Palmaz, J.C.1
  • 5
    • 33747048770 scopus 로고    scopus 로고
    • Do device characteristics impact outcome in carotid artery stenting?
    • DOI 10.1016/j.jvs.2006.06.029, PII S0741521406011487
    • Hart JP, Peeters P, Verbist J, et al. Do device characteristics impact outcome in carotid artery stenting? J Vasc Surg. 2006;44:725-731. (Pubitemid 44441788)
    • (2006) Journal of Vascular Surgery , vol.44 , Issue.4 , pp. 725-730
    • Hart, J.P.1    Peeters, P.2    Verbist, J.3    Deloose, K.4    Bosiers, M.5
  • 9
    • 69949104161 scopus 로고    scopus 로고
    • 30-Day outcomes for carotid artery stenting in 6320 patients from two prospective, multicenter, high surgical risk registries
    • in press
    • Gray WA, Chaturvedi S, Verta P. 30-day outcomes for carotid artery stenting in 6320 patients from two prospective, multicenter, high surgical risk registries. Circ Cardiovasc Intervent 2009; in press.
    • (2009) Circ Cardiovasc Intervent
    • Gray, W.A.1    Chaturvedi, S.2    Verta, P.3
  • 10
    • 44949088531 scopus 로고    scopus 로고
    • Treatment of Asymptomatic Carotid Disease with Stenting: Pro
    • DOI 10.1053/j.semvascsurg.2008.03.005, PII S0895796708000227
    • Wholey MH, Barbato JE, Al-Khoury GE. Treatment of asymptomatic carotid disease with stenting: pro. Semin Vasc Surg. 2008;21:95-99. (Pubitemid 351815179)
    • (2008) Seminars in Vascular Surgery , vol.21 , Issue.2 , pp. 95-99
    • Wholey, M.H.1    Barbato, J.E.2    Al-Khoury, G.E.3
  • 12
    • 34548593681 scopus 로고    scopus 로고
    • Delivery and release of nitinol stent in carotid artery and their interactions: A finite element analysis
    • DOI 10.1016/j.jbiomech.2007.02.024, PII S0021929007001145
    • Wu W, Qi M, Liu XP, et al. Delivery and release of nitinol stent in carotid artery and their interactions: a finite element analysis. J Biomech. 2007;40:3034-3040. (Pubitemid 47385815)
    • (2007) Journal of Biomechanics , vol.40 , Issue.13 , pp. 3034-3040
    • Wu, W.1    Qi, M.2    Liu, X.-P.3    Yang, D.-Z.4    Wang, W.-Q.5
  • 13
    • 0742321993 scopus 로고    scopus 로고
    • Effects of stent stiffness on local haemodynamics with particular reference to wave reflections
    • DOI 10.1016/S0021-9290(03)00289-6
    • Alderson H, Zamir M. Effects of stent stiffness on local haemodynamics with particular reference to wave reflections. J Biomech. 2004;37:339-348. (Pubitemid 38156082)
    • (2004) Journal of Biomechanics , vol.37 , Issue.3 , pp. 339-348
    • Alderson, H.1    Zamir, M.2
  • 16
    • 34247382151 scopus 로고    scopus 로고
    • Predictive haemodynamics in a one-dimensional human carotid artery bifurcation. Part I: Application to stent design
    • DOI 10.1109/TBME.2006.889188, 6
    • Kolachalama VB, Bressloff NW, Nair PB, et al. Predictive haemodynamics in a one-dimensional human carotid artery bifurcation. Part I: Application to stent design. IEEE Trans Biomed Eng. 2007;54:802-812. (Pubitemid 46628575)
    • (2007) IEEE Transactions on Biomedical Engineering , vol.54 , Issue.5 , pp. 802-812
    • Kolachalama, V.B.1    Bressloff, N.W.2    Nair, P.B.3    Shearman, C.P.4
  • 17
    • 34147173952 scopus 로고    scopus 로고
    • A general finite element analysis method for balloon expandable stents based on repeated unit cell (RUC) model
    • DOI 10.1016/j.finel.2007.01.001, PII S0168874X07000054
    • Xia Z, Ju F, Sasaki K. A general finite element analysis method for balloon expandable stents based on repeated unit cell (RUC) model. Finite Elem Anal Des. 2007;43:649-658. (Pubitemid 46560173)
    • (2007) Finite Elements in Analysis and Design , vol.43 , Issue.8 , pp. 649-658
    • Xia, Z.1    Ju, F.2    Sasaki, K.3
  • 19
    • 44649179914 scopus 로고    scopus 로고
    • Suggestion of potential stent design parameters to reduce restenosis risk driven by foreshortening or dogboning due to non-uniform balloon-stent expansion
    • Lim D, Cho SK, Park WP, et al. Suggestion of potential stent design parameters to reduce restenosis risk driven by foreshortening or dogboning due to non-uniform balloon-stent expansion. Ann Biomed Eng. 2008;36:1118-1129.
    • (2008) Ann Biomed Eng , vol.36 , pp. 1118-1129
    • Lim, D.1    Cho, S.K.2    Park, W.P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.