1
-
-
0035054285
-
Death as a complication of peripherally inserted central catheters in neonates
-
Nadroo AM, Lin J, Green RS, Magid MS, Holzman IR. Death as a complication of peripherally inserted central catheters in neonates. J Pediatr 2001;138:599-601.
-
(2001)
J Pediatr
, vol.138
, pp. 599-601
-
-
Nadroo, A.M.1
Lin, J.2
Green, R.S.3
Magid, M.S.4
Holzman, I.R.5
-
2
-
-
0035406318
-
Survival after an acute pericardial tamponade as a result of percutaneously inserted central venous catheter in a pretermneonate
-
Kabra NS, Kluckow MR. Survival after an acute pericardial tamponade as a result of percutaneously inserted central venous catheter in a pretermneonate. Indian J Pediatr 2001;68:677-680.
-
(2001)
Indian J Pediatr
, vol.68
, pp. 677-680
-
-
Kabra, N.S.1
Kluckow, M.R.2
-
3
-
-
0027568103
-
Central venous catheters in low birth weight infants: Incidence of related complications
-
Schiff DE, Stonestreet BS. Central venous catheters in low birth weight infants: Incidence of related complications. J Perinatol 1993;13:153-158.
-
(1993)
J Perinatol
, vol.13
, pp. 153-158
-
-
Schiff, D.E.1
Stonestreet, B.S.2
-
4
-
-
0038679753
-
Pericardial effusion and cardiac tamponade as complications of neonatal long lines: Are they really a problem?
-
Beardsall K, White DK, Pinto EM, Kelsall AWR. Pericardial effusion and cardiac tamponade as complications of neonatal long lines: Are they really a problem? Arch Dis Child Fetal Neonatal Ed 2003;88:F292-F295.
-
(2003)
Arch Dis Child Fetal Neonatal Ed
, vol.88
-
-
Beardsall, K.1
White, D.K.2
Pinto, E.M.3
Kelsall, A.W.R.4
-
6
-
-
0027486372
-
Massive pericardial effusion as a cause for sudden deterioration of a very low birthweight infant
-
Wirrell EC, Pelausa EO, Allen AC, Stinson DA, Hanna BD. Massive pericardial effusion as a cause for sudden deterioration of a very low birthweight infant. Am J Perinatol 1993;10:419-423.
-
(1993)
Am J Perinatol
, vol.10
, pp. 419-423
-
-
Wirrell, E.C.1
Pelausa, E.O.2
Allen, A.C.3
Stinson, D.A.4
Hanna, B.D.5
-
7
-
-
0036306769
-
Central catheters in neonates. Changes in upper extremity position cause migration of peripherally inserted
-
Nadroo AM, Glass RB, Lin J, Green RS, Holzman IR. Central catheters in neonates. Changes in upper extremity position cause migration of peripherally inserted. Pediatrics 2002;110:131-136.
-
(2002)
Pediatrics
, vol.110
, pp. 131-136
-
-
Nadroo, A.M.1
Glass, R.B.2
Lin, J.3
Green, R.S.4
Holzman, I.R.5
-
8
-
-
8144227889
-
Central venous lines in neonates: A study of 2186 catheters
-
Cartwright DW. Central venous lines in neonates: A study of 2186 catheters. Arch Dis Child Fetal Neonatal Ed 2004;89:504-508.
-
(2004)
Arch Dis Child Fetal Neonatal Ed
, vol.89
, pp. 504-508
-
-
Cartwright, D.W.1
-
9
-
-
0035046846
-
Perforation complications of percutaneous central venous catheters in very low birthweight infants
-
Ja Leipälä, Petäjä J, Fellman V. Perforation complications of percutaneous central venous catheters in very low birthweight infants. J Paediatr Child Health 2001;37:168-171.
-
(2001)
J Paediatr Child Health
, vol.37
, pp. 168-171
-
-
Leipälä, J.1
Petäjä, J.2
Fellman, V.3
-
11
-
-
0021035152
-
Hydrothorax as a late complication of central venous indwelling catheters
-
Iberti TJ, Katz LB, Reiner MA, Brownie T, Kwun KB. Hydrothorax as a late complication of central venous indwelling catheters. Surgery 1983;94:842-846.
-
(1983)
Surgery
, vol.94
, pp. 842-846
-
-
Iberti, T.J.1
Katz, L.B.2
Reiner, M.A.3
Brownie, T.4
Kwun, K.B.5
-
12
-
-
0021240488
-
Bilateral hydrothorax as a life-threatening complication of central venous hyperalimentation
-
McDonnell PJ, Qualman SJ, Hutchins GM. Bilateral hydrothorax as a life-threatening complication of central venous hyperalimentation. Surg Gynecol Obstet 1984;158:577-579.
-
(1984)
Surg Gynecol Obstet
, vol.158
, pp. 577-579
-
-
McDonnell, P.J.1
Qualman, S.J.2
Hutchins, G.M.3
-
13
-
-
0036305258
-
Pericardial effusion and tamponade in infants with central catheters
-
Nowlen TT, Rosenthal GL, Johnson GL, Tom DJ, Vargo TA. Pericardial effusion and tamponade in infants with central catheters. Pediatrics 2002;110:137-142.
-
(2002)
Pediatrics
, vol.110
, pp. 137-142
-
-
Nowlen, T.T.1
Rosenthal, G.L.2
Johnson, G.L.3
Tom, D.J.4
Vargo, T.A.5
-
14
-
-
0025833934
-
Bilateral pleural and pericardial effusions because of mediastinal placement of a central venous catheter
-
Simmons TC, Henderson DR. Bilateral pleural and pericardial effusions because of mediastinal placement of a central venous catheter. JPEN J Parenter Enteral Nutr 1991;6:676-679.
-
(1991)
JPEN J Parenter Enteral Nutr
, vol.6
, pp. 676-679
-
-
Simmons, T.C.1
Henderson, D.R.2
-
15
-
-
2042502357
-
-
Pignotti MS, Messeri A, Donzelli G. Thoracentesis in pericardial and pleural effusion caused by central venous catheterization: A less invasive neonatal approach. Pediatric Anesthesia 2004;14:349-351.
-
Pignotti MS, Messeri A, Donzelli G. Thoracentesis in pericardial and pleural effusion caused by central venous catheterization: A less invasive neonatal approach. Pediatric Anesthesia 2004;14:349-351.
-
-
-
-
16
-
-
33644878681
-
-
Nadroo AM.Thoracocentesis in pericardial and pleural effusion caused by central venous catheterization:Aless invasive neonatal approach? Pediatric Anesthesia 2005;15:1145-1151.
-
Nadroo AM.Thoracocentesis in pericardial and pleural effusion caused by central venous catheterization:Aless invasive neonatal approach? Pediatric Anesthesia 2005;15:1145-1151.
-
-
-
-
17
-
-
12944304177
-
Central venous catheters and cardiac tamponade in preterm infants
-
Pezzati M, Filippi L, Chiti G, Dani C, Rossi S, Bertini G, Rubaltelli FF. Central venous catheters and cardiac tamponade in preterm infants. Intensive Care Med 2004;30:2253-2256.
-
(2004)
Intensive Care Med
, vol.30
, pp. 2253-2256
-
-
Pezzati, M.1
Filippi, L.2
Chiti, G.3
Dani, C.4
Rossi, S.5
Bertini, G.6
Rubaltelli, F.F.7
|