메뉴 건너뛰기




Volumn 53, Issue 3, 2009, Pages 368-373

Patient radiation dose during percutaneous interventional closure of interatrial communications

Author keywords

Atrial septal defect; Fluoroscopy time; Foramen ovale; Percutaneous closure; Radiation exposure

Indexed keywords

ADULT; AGED; ARTICLE; CLINICAL ARTICLE; FEMALE; FLUOROSCOPY; HEART ATRIUM SEPTUM DEFECT; HEART CATHETER; HEART SURGERY; HUMAN; MALE; PATENT FORAMEN OVALE; RADIATION DOSE; RADIATION EXPOSURE; RADIATION SAFETY; TRANSESOPHAGEAL ECHOCARDIOGRAPHY;

EID: 67249090368     PISSN: 09145087     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jjcc.2009.01.001     Document Type: Article
Times cited : (22)

References (10)
  • 2
    • 42649106144 scopus 로고    scopus 로고
    • Radiation exposure in invasive cardiology
    • Kuon E. Radiation exposure in invasive cardiology. Heart 94 (2008) 667-674
    • (2008) Heart , vol.94 , pp. 667-674
    • Kuon, E.1
  • 3
    • 28144451370 scopus 로고    scopus 로고
    • Radiation in the cardiac catheter laboratory
    • Partridge J. Radiation in the cardiac catheter laboratory. Heart 91 (2005) 1615-1620
    • (2005) Heart , vol.91 , pp. 1615-1620
    • Partridge, J.1
  • 4
    • 0037448797 scopus 로고    scopus 로고
    • Intracardiac echocardiography is superior to conventional monitoring for guiding device closure of interatrial communications
    • Bartel T., Konorza T., Arjumand J., Ebradlidze T., Eggebrecht H., Caspari G., Neudorf U., and Erbel R. Intracardiac echocardiography is superior to conventional monitoring for guiding device closure of interatrial communications. Circulation 107 (2003) 795-797
    • (2003) Circulation , vol.107 , pp. 795-797
    • Bartel, T.1    Konorza, T.2    Arjumand, J.3    Ebradlidze, T.4    Eggebrecht, H.5    Caspari, G.6    Neudorf, U.7    Erbel, R.8
  • 5
    • 0031813469 scopus 로고    scopus 로고
    • Initial clinical results with the Amplatzer septal occluder-a self-centering double disc for occlusion of atrial septal defects
    • [in German]
    • Berger F., Ewert P., Stiller B., Dähnert I., Krings G., Vogel M., and Lange P.E. Initial clinical results with the Amplatzer septal occluder-a self-centering double disc for occlusion of atrial septal defects. Z Cardiol 87 (1998) 185-190 [in German]
    • (1998) Z Cardiol , vol.87 , pp. 185-190
    • Berger, F.1    Ewert, P.2    Stiller, B.3    Dähnert, I.4    Krings, G.5    Vogel, M.6    Lange, P.E.7
  • 6
    • 54549090021 scopus 로고    scopus 로고
    • Percutaneous, minimally invasive retrieval of a dislodged and impacted device from the abdominal aorta, four months after closure of an atrial septal defect
    • Wagdi P., and Kunz M. Percutaneous, minimally invasive retrieval of a dislodged and impacted device from the abdominal aorta, four months after closure of an atrial septal defect. Am J Cardiol 102 (2008) 1111-1112
    • (2008) Am J Cardiol , vol.102 , pp. 1111-1112
    • Wagdi, P.1    Kunz, M.2
  • 8
    • 39749202872 scopus 로고    scopus 로고
    • Long-term results after fluoroscopy-guided closure of patent foramen ovale for secondary prevention of paradoxical embolism
    • Wahl A., Kunz M., Moschovitis A., Nageh T., Schwerzmann M., Seiler C., Mattle H.P., Windecker S., and Meier B. Long-term results after fluoroscopy-guided closure of patent foramen ovale for secondary prevention of paradoxical embolism. Heart 94 (2008) 336-341
    • (2008) Heart , vol.94 , pp. 336-341
    • Wahl, A.1    Kunz, M.2    Moschovitis, A.3    Nageh, T.4    Schwerzmann, M.5    Seiler, C.6    Mattle, H.P.7    Windecker, S.8    Meier, B.9
  • 9
    • 33846300728 scopus 로고    scopus 로고
    • Echocardiographic visualization of laceration of atrial septum during balloon sizing of atrial septal defect
    • Alsaileek A.A., Omran A., Godman M., and Najm H.K. Echocardiographic visualization of laceration of atrial septum during balloon sizing of atrial septal defect. Eur J Echocardiogr 8 (2005) 155-157
    • (2005) Eur J Echocardiogr , vol.8 , pp. 155-157
    • Alsaileek, A.A.1    Omran, A.2    Godman, M.3    Najm, H.K.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.