메뉴 건너뛰기




Volumn 7261, Issue , 2009, Pages

Quantification of abdominal aortic deformation after EVAR

Author keywords

Modeling; Monitoring and feedback; Registration; Segmentation; Validation evaluation

Indexed keywords

ABDOMINAL SCANS; CENTERLINE; DEFORMATION FIELD; DISPLACEMENT FIELD; ENDOVASCULAR; ENDOVASCULAR STENTING; FLOW CHARACTERISTIC; GUIDE-WIRE; INTERVENTIONAL; MEDICAL INSTRUMENTS; MODELING; NON-RIGID DEFORMATION; NONRIGID REGISTRATION; PATIENT DATASETS; REGION OF INTEREST; REGISTRATION; RIGID TRANSFORMATIONS; SEGMENTATION; SEVERE DEFORMATION; STENT GRAFTS; VALIDATION/EVALUATION; VASCULAR SURGEONS; VISUAL ASSESSMENTS;

EID: 67149110254     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.812566     Document Type: Conference Paper
Times cited : (11)

References (14)
  • 5
    • 0034766788 scopus 로고    scopus 로고
    • Imaging of complications after endoluminal treatment of abdominal aortic aneurysms
    • DOI 10.1007/s003300100912
    • J. Golzarian and J. Struyven, "Imaging of complications after endoluminal treatment of abdominal aortic aneurysms," Eur Radiol 11, pp. 2244-2251, 2001. (Pubitemid 33041091)
    • (2001) European Radiology , vol.11 , Issue.11 , pp. 2244-2251
    • Golzarian, J.1    Struyven, J.2
  • 6
    • 84993748620 scopus 로고    scopus 로고
    • Late failures of devices used for endovascular treatment of abdominal aortic aneurysm: What have we learned and what is the task for the future?
    • H. G. Beebe, "Late failures of devices used for endovascular treatment of abdominal aortic aneurysm: What have we learned and what is the task for the future?," Pers Vasc Surg Endovasc Ther 14(1), pp. 29-49, 2001.
    • (2001) Pers Vasc Surg Endovasc Ther , vol.14 , Issue.1 , pp. 29-49
    • Beebe, H.G.1
  • 9
    • 14044270157 scopus 로고    scopus 로고
    • Non-rigid image registration: Theory and practice
    • DOI 10.1259/bjr/25329214
    • W. R. Crum, T. Hartkens, and D. L. G. Hill, "Non-rigid image registration: theory and practice," The British Journal of Radiology 77, pp. S140-S153, 2004. (Pubitemid 40277714)
    • (2004) British Journal of Radiology , vol.77 , Issue.SPEC. ISS. 2
    • Crum, W.R.1    Hartkens, T.2    Hill, D.L.G.3
  • 10
    • 44949131799 scopus 로고    scopus 로고
    • Advanced 2d-3d registration for endovascular aortic interventions: Addressing dissimilarity in images
    • M.I. Miga and K. R. Cleary, eds.
    • S. Demirci, O. Kutter, F. Manstad-Hulaas, R. Bauernschmitt, and N. Navab, "Advanced 2d-3d registration for endovascular aortic interventions: Addressing dissimilarity in images," in Proc. of SPIE Medical Imaging, M. I. Miga and K. R. Cleary, eds., 6918, 2008.
    • (2008) in Proc. of SPIE Medical Imaging , vol.6918
    • Demirci, S.1    Kutter, O.2    Manstad-Hulaas, F.3    Bauernschmitt, R.4    Navab, N.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.