메뉴 건너뛰기




Volumn 50, Issue 8, 2009, Pages 1891-1901

On-road performance analysis of R134a/R600a/R290 refrigerant mixture in an automobile air-conditioning system with mineral oil as lubricant

Author keywords

Alternate refrigerants; Automobile air conditioning; Oil miscibility; R134a R600a R290 mixture; Refrigerant blend; Retrofitting R12 systems

Indexed keywords

AIRCONDITIONING SYSTEMS; ALTERNATE REFRIGERANTS; AMBIENT CONDITIONS; AUTOMOBILE INDUSTRY; LOWER FLAMMABLE LIMITS; OIL MISCIBILITY; R134A/R600A/R290 MIXTURE; REFRIGERANT MIXTURES; ROAD PERFORMANCE; RUNNING CONDITIONS; TEST RESULTS; TRAFFIC CONDITIONS;

EID: 67149102487     PISSN: 01968904     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.enconman.2009.04.027     Document Type: Article
Times cited : (30)

References (18)
  • 1
    • 67349220506 scopus 로고    scopus 로고
    • Paranjpey Ramesh. Automobile air conditioning systems special considerations. ACRECONF, India; 2003. p. 279-1.
    • Paranjpey Ramesh. Automobile air conditioning systems special considerations. ACRECONF, India; 2003. p. 279-1.
  • 2
    • 67349261825 scopus 로고    scopus 로고
    • Indian Standard. Automotive vehicles - air conditioning systems thermal performance - method of measurement
    • IS 14618;
    • Indian Standard. Automotive vehicles - air conditioning systems thermal performance - method of measurement, IS 14618; 1999.
    • (1999)
  • 3
    • 0347759907 scopus 로고    scopus 로고
    • Ozone friendly HFC134a/HC mixture compatible with mineral oil in refrigeration system improves energy efficiency of a walk in cooler
    • Joseph Sekhar S., Senthil Kumar K., and Mohan Lal D. Ozone friendly HFC134a/HC mixture compatible with mineral oil in refrigeration system improves energy efficiency of a walk in cooler. Energy Convers Manage 45 (2004) 1175-1186
    • (2004) Energy Convers Manage , vol.45 , pp. 1175-1186
    • Joseph Sekhar, S.1    Senthil Kumar, K.2    Mohan Lal, D.3
  • 4
    • 20144381491 scopus 로고    scopus 로고
    • HFC134a/HC600a/HC290 mixture a retrofit for R12 systems
    • Sekhar S.J., and Mohan Lal D. HFC134a/HC600a/HC290 mixture a retrofit for R12 systems. Int J Refrig 28 (2005) 735-743
    • (2005) Int J Refrig , vol.28 , pp. 735-743
    • Sekhar, S.J.1    Mohan Lal, D.2
  • 5
    • 0032092186 scopus 로고    scopus 로고
    • Thermodynamic properties of alternative refrigerants
    • Mclinden M.O., Lemmon E.W., and Jacobsen R.R. Thermodynamic properties of alternative refrigerants. Int J Refrig 21 4 (1998) 322-338
    • (1998) Int J Refrig , vol.21 , Issue.4 , pp. 322-338
    • Mclinden, M.O.1    Lemmon, E.W.2    Jacobsen, R.R.3
  • 7
    • 0031274540 scopus 로고    scopus 로고
    • Performance analysis of an automobile air conditioning system with R22/R124/R152a refrigerant
    • Kiatsiriroat T., and Euakit T. Performance analysis of an automobile air conditioning system with R22/R124/R152a refrigerant. Appl Therm Eng 17 11 (1997) 1085-1097
    • (1997) Appl Therm Eng , vol.17 , Issue.11 , pp. 1085-1097
    • Kiatsiriroat, T.1    Euakit, T.2
  • 8
    • 0038802897 scopus 로고    scopus 로고
    • Experimental and computer performance study of an automotive air conditioning system with alternative refrigerants
    • Joudi K.A., Mohammed A.S.K., and Aljanabi Md.K. Experimental and computer performance study of an automotive air conditioning system with alternative refrigerants. Energy Convers Manage 44 (2003) 2959-2976
    • (2003) Energy Convers Manage , vol.44 , pp. 2959-2976
    • Joudi, K.A.1    Mohammed, A.S.K.2    Aljanabi, Md.K.3
  • 9
    • 0031656274 scopus 로고    scopus 로고
    • An experimental study on HC290 and a commercial LPG mix as suitable replacement for HCF22
    • Purkayastha B., and Bansal P.K. An experimental study on HC290 and a commercial LPG mix as suitable replacement for HCF22. Int J Refrig 21 1 (1998) 3-12
    • (1998) Int J Refrig , vol.21 , Issue.1 , pp. 3-12
    • Purkayastha, B.1    Bansal, P.K.2
  • 10
    • 0036525691 scopus 로고    scopus 로고
    • Experimental studies of new refrigerant mixtures to replace R12 in domestic refrigerators
    • Taohtoush B., Tahat M., and Snudeifat M.A. Experimental studies of new refrigerant mixtures to replace R12 in domestic refrigerators. Appl Therm Eng 22 (2002) 495-506
    • (2002) Appl Therm Eng , vol.22 , pp. 495-506
    • Taohtoush, B.1    Tahat, M.2    Snudeifat, M.A.3
  • 12
    • 0037355534 scopus 로고    scopus 로고
    • An experimental analysis of automotive air conditioning system
    • Kaynakh O., and Horaz I. An experimental analysis of automotive air conditioning system. Int Commun Heat Mass Transfer 30 2 (2003) 273-284
    • (2003) Int Commun Heat Mass Transfer , vol.30 , Issue.2 , pp. 273-284
    • Kaynakh, O.1    Horaz, I.2
  • 15
    • 67149129507 scopus 로고    scopus 로고
    • Performance evaluation of an integrated automotive air conditioning and heat pump system
    • Hosoz M., and Direk M. Performance evaluation of an integrated automotive air conditioning and heat pump system. Energy Convers Manage (2005)
    • (2005) Energy Convers Manage
    • Hosoz, M.1    Direk, M.2
  • 16
    • 0033893377 scopus 로고    scopus 로고
    • Performance analysis and simulation of automobile air conditioning system
    • Lee G.H., and Yoo J.Y. Performance analysis and simulation of automobile air conditioning system. Int J Refrig 23 (2000) 243-254
    • (2000) Int J Refrig , vol.23 , pp. 243-254
    • Lee, G.H.1    Yoo, J.Y.2