Volumn 110, Issue 6, 2009, Pages 1235-1243

Extraneural versus intraneural stimulation thresholds during ultrasound-guided supraclavicular block

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ARTICLE; BRACHIAL PLEXUS ANESTHESIA; CONTROLLED STUDY; DIABETES MELLITUS; EXTRANEURAL STIMULATION; FEMALE; FOLLOW UP; HUMAN; INTRANEURAL STIMULATION; MAJOR CLINICAL STUDY; MALE; NERVE INJURY; NERVE STIMULATION; PERCEPTIVE THRESHOLD; PRIORITY JOURNAL; QUALITATIVE ANALYSIS; RELIABILITY; STIMULUS RESPONSE; ULTRASOUND GUIDED BRACHIAL PLEXUS ANESTHESIA; ADOLESCENT; BRACHIAL PLEXUS; ECHOGRAPHY; ELECTROSTIMULATION; HAND; HISTOLOGY; IMAGE PROCESSING; INNERVATION; INSTRUMENTATION; METHODOLOGY; MIDDLE AGED; MOTONEURON; MUSCLE CONTRACTION; NEEDLE; NERVE BLOCK; PAIN THRESHOLD; PATHOPHYSIOLOGY; PHYSIOLOGY; SENSORY RECEPTOR; SKELETAL MUSCLE; WRIST;

EID: 67049117483     PISSN: 00033022     EISSN: 15281175     Source Type: Journal    
DOI: 10.1097/ALN.0b013e3181a59891     Document Type: Article
Times cited : (158)

References (44)
  • 1
    • 11444265045 scopus 로고    scopus 로고
    • Nielsen KC, Guller U, Steele SM, Klein SM, Greengrass RA, Pietrobon R: Influence of obesity on surgical regional anesthesia in the ambulatory setting: An analysis of 9,038 blocks. ANESTHESIOIOGY2005; 102:181-7
    • Nielsen KC, Guller U, Steele SM, Klein SM, Greengrass RA, Pietrobon R: Influence of obesity on surgical regional anesthesia in the ambulatory setting: An analysis of 9,038 blocks. ANESTHESIOIOGY2005; 102:181-7
  • 2
    • 0033863526 scopus 로고    scopus 로고
    • Recurring brachial plexus neuropathy in a diabetic patient after shoulder surgery and continuous interscalene block
    • Horlocker TT, O'Driscoll SW, Dinapoli RP: Recurring brachial plexus neuropathy in a diabetic patient after shoulder surgery and continuous interscalene block. Anesth Analg 2000; 91:688-90
    • (2000) Anesth Analg , vol.91 , pp. 688-690
    • Horlocker, T.T.1    O'Driscoll, S.W.2    Dinapoli, R.P.3
  • 4
    • 0029100729 scopus 로고
    • Neurological complications of central nerve blocks
    • Renck H: Neurological complications of central nerve blocks. Acta Anaes-thesiol Scand 1995; 39:859-68
    • (1995) Acta Anaes-thesiol Scand , vol.39 , pp. 859-868
    • Renck, H.1
  • 7
    • 0018340781 scopus 로고
    • Peripheral nerve injection injury: An experimental study
    • Gentili F, Hudson A, Kline DG, Hunter D: Peripheral nerve injection injury: An experimental study. Neurosurgery 1979; 4:244-53
    • (1979) Neurosurgery , vol.4 , pp. 244-253
    • Gentili, F.1    Hudson, A.2    Kline, D.G.3    Hunter, D.4
  • 8
    • 0018860073 scopus 로고
    • Early changes following injection injury of peripheral nerves
    • Gentili F, Hudson AR, Kline D, Hunter D: Early changes following injection injury of peripheral nerves. Can J Surg 1980; 23:177-82
    • (1980) Can J Surg , vol.23 , pp. 177-182
    • Gentili, F.1    Hudson, A.R.2    Kline, D.3    Hunter, D.4
  • 10
    • 0018145313 scopus 로고
    • Longitudinal spread of intraneurally injected local anesthetics. An experimental study of the initial neural distribution following intraneural injections
    • Selander D, Sjostrand J: Longitudinal spread of intraneurally injected local anesthetics. An experimental study of the initial neural distribution following intraneural injections. Acta Anaesthesiol Scand 1978; 22:622-34
    • (1978) Acta Anaesthesiol Scand , vol.22 , pp. 622-634
    • Selander, D.1    Sjostrand, J.2
  • 12
    • 2542449139 scopus 로고    scopus 로고
    • Peripheral nerve stimulators: Cracking the code- one at a time
    • Hadzic A: Peripheral nerve stimulators: Cracking the code- one at a time. Reg Anesth Pain Med 2004; 29:185-8
    • (2004) Reg Anesth Pain Med , vol.29 , pp. 185-188
    • Hadzic, A.1
  • 13
  • 14
    • 2542492934 scopus 로고    scopus 로고
    • Hadzic A, VlokaJD, Claudio RE, Hadzic N, Thys DM, Santos AC: Electrical nerve localization: Effects of cutaneous electrode placement and duration of the stimulus on motor response. ANESTHESIOIOGY 2004; 100:1526-30
    • Hadzic A, VlokaJD, Claudio RE, Hadzic N, Thys DM, Santos AC: Electrical nerve localization: Effects of cutaneous electrode placement and duration of the stimulus on motor response. ANESTHESIOIOGY 2004; 100:1526-30
  • 15
    • 33748094264 scopus 로고    scopus 로고
    • The sensitivity of motor response to nerve stimulation and paresthesia for nerve localization as evaluated by ultrasound
    • Perlas A, Niazi A, McCartney C, Chan V, Xu D, Abbas S: The sensitivity of motor response to nerve stimulation and paresthesia for nerve localization as evaluated by ultrasound. Reg Anesth Pain Med 2006; 31:445-50
    • (2006) Reg Anesth Pain Med , vol.31 , pp. 445-450
    • Perlas, A.1    Niazi, A.2    McCartney, C.3    Chan, V.4    Xu, D.5    Abbas, S.6
  • 16
    • 34247513349 scopus 로고    scopus 로고
    • An ultrasonographic and histological study of intraneural injection and electrical stimulationin pigs
    • Chan VW, Brull R, McCartney CJ, Xu D, Abbas S, Shannon P: An ultrasonographic and histological study of intraneural injection and electrical stimulationin pigs. Anesth Analg 2007; 104:1281-4
    • (2007) Anesth Analg , vol.104 , pp. 1281-1284
    • Chan, V.W.1    Brull, R.2    McCartney, C.J.3    Xu, D.4    Abbas, S.5    Shannon, P.6
  • 18
    • 33751327557 scopus 로고    scopus 로고
    • Ultrasound-guided supraclavicular brachial plexus block: A modified Plumb-Bob technique
    • Collins AB, Gray AT, Kessler J: Ultrasound-guided supraclavicular brachial plexus block: A modified Plumb-Bob technique. Reg Anesth Pain Med 2006; 31:591-2
    • (2006) Reg Anesth Pain Med , vol.31 , pp. 591-592
    • Collins, A.B.1    Gray, A.T.2    Kessler, J.3
  • 19
    • 34447345941 scopus 로고    scopus 로고
    • Klaastad o: Ultrasound controlled nerve stimulation in the elbow region: High currents and short distances needed to obtain motor responses
    • Sauter AR, Dodgson MS, Stubhaug A, Cvancarova M, Klaastad o: Ultrasound controlled nerve stimulation in the elbow region: High currents and short distances needed to obtain motor responses. Acta Anaesthesiol Scand 2007;51:942-8
    • (2007) Acta Anaesthesiol Scand , vol.51 , pp. 942-948
    • Sauter, A.R.1    Dodgson, M.S.2    Stubhaug, A.3    Cvancarova, M.4
  • 20
    • 0041963046 scopus 로고    scopus 로고
    • Perlas A, Chan VW, Simons M: Brachial plexus examination and localization using ultrasound and electrical stimulation: A volunteer study. ANESTHESIOIOGY 2003; 99:429-35
    • Perlas A, Chan VW, Simons M: Brachial plexus examination and localization using ultrasound and electrical stimulation: A volunteer study. ANESTHESIOIOGY 2003; 99:429-35
  • 21
    • 33749185441 scopus 로고    scopus 로고
    • Bigeleisen PE: Nerve puncture and apparent intraneural injection during ultrasound-guided axillary block does not invariably result in neurologic injury. ANESTHESIOIOGY 2006; 105:779-83
    • Bigeleisen PE: Nerve puncture and apparent intraneural injection during ultrasound-guided axillary block does not invariably result in neurologic injury. ANESTHESIOIOGY 2006; 105:779-83
  • 22
    • 34249739159 scopus 로고    scopus 로고
    • Brull R, Chan VW, McCartney CJ, Perlas A, Xu D: Ultrasound detects intraneural injection (Letter). ANESTHESIOIOGY 2007; 106:1244
    • Brull R, Chan VW, McCartney CJ, Perlas A, Xu D: Ultrasound detects intraneural injection (Letter). ANESTHESIOIOGY 2007; 106:1244
  • 23
    • 32744476491 scopus 로고    scopus 로고
    • Ultrasound evidence of intraneural injection
    • Chan VW: Ultrasound evidence of intraneural injection. Anesth Analg 2005; 101:610-1
    • (2005) Anesth Analg , vol.101 , pp. 610-611
    • Chan, V.W.1
  • 24
    • 0034823262 scopus 로고    scopus 로고
    • Peripheral nerve stimulation in the practice of brachial plexus anesthesia: A review
    • De Andres J, Sala-Blanch X: Peripheral nerve stimulation in the practice of brachial plexus anesthesia: A review. Reg Anesth Pain Med 2001; 26:478-83
    • (2001) Reg Anesth Pain Med , vol.26 , pp. 478-483
    • De Andres, J.1    Sala-Blanch, X.2
  • 26
    • 84862907415 scopus 로고
    • The use of peripheral nerve stimulator for regional anesthesia
    • Pither CE, Raj P, Ford DJ: The use of peripheral nerve stimulator for regional anesthesia. Reg Anesth 1985; 10:49-58
    • (1985) Reg Anesth , vol.10 , pp. 49-58
    • Pither, C.E.1    Raj, P.2    Ford, D.J.3
  • 27
    • 0036187523 scopus 로고    scopus 로고
    • Urmey WF, Stanton J: Inability to consistently elicit a motor response following sensory paresthesia during interscalene block administration. ANESTHESIOIOGY 2002; 96:552-4
    • Urmey WF, Stanton J: Inability to consistently elicit a motor response following sensory paresthesia during interscalene block administration. ANESTHESIOIOGY 2002; 96:552-4
  • 28
    • 67650085110 scopus 로고    scopus 로고
    • Duong CY, Tran de QH: Use of radiographic contrast to confirm the
    • Duong CY, Tran de QH: Use of radiographic contrast to confirm the
  • 29
    • 33748108791 scopus 로고    scopus 로고
    • placement of a sciatic catheter in a patient presenting an atypical response to neurostimulation
    • placement of a sciatic catheter in a patient presenting an atypical response to neurostimulation. Reg Anesth Pain Med 2006;31: 482-3
    • (2006) Reg Anesth Pain Med , vol.31 , pp. 482-483
  • 30
    • 0141751845 scopus 로고    scopus 로고
    • Ultrasound-guided popliteal block demonstrates an atypical motor response to nerve stimulation in 2 patients with diabetes mellitus
    • Sites BD, Gallagher J, Sparks M: Ultrasound-guided popliteal block demonstrates an atypical motor response to nerve stimulation in 2 patients with diabetes mellitus. Reg Anesth Pain Med 2003; 28:479-82
    • (2003) Reg Anesth Pain Med , vol.28 , pp. 479-482
    • Sites, B.D.1    Gallagher, J.2    Sparks, M.3
  • 31
    • 30344464098 scopus 로고    scopus 로고
    • Long current impulses may be required for nerve stimulation in patients with ischemic pain
    • Szerb J, Persaud D: Long current impulses may be required for nerve stimulation in patients with ischemic pain. Can J Anaesth 2005; 52:963-6
    • (2005) Can J Anaesth , vol.52 , pp. 963-966
    • Szerb, J.1    Persaud, D.2
  • 32
    • 0030983181 scopus 로고    scopus 로고
    • Risk factors for diabetic peripheral sensory neuropathy. Results of the Seattle Prospective Diabetic Foot Study
    • Adler AI, Boyko EJ, Ahroni JH, Stensel V, Forsberg RC, Smith DG: Risk factors for diabetic peripheral sensory neuropathy. Results of the Seattle Prospective Diabetic Foot Study. Diabetes Care 1997; 20:1162-7
    • (1997) Diabetes Care , vol.20 , pp. 1162-1167
    • Adler, A.I.1    Boyko, E.J.2    Ahroni, J.H.3    Stensel, V.4    Forsberg, R.C.5    Smith, D.G.6
  • 33
    • 0029038374 scopus 로고
    • Natural history of peripheral neuropathy in patients with non-insulin-dependent diabetes mellitus
    • Partanen J, Niskanen L, Lehtinen J, Mervaala E, Siitonen O, Uusitupa M: Natural history of peripheral neuropathy in patients with non-insulin-dependent diabetes mellitus. N Engl J Med 1995; 333:89-94
    • (1995) N Engl J Med , vol.333 , pp. 89-94
    • Partanen, J.1    Niskanen, L.2    Lehtinen, J.3    Mervaala, E.4    Siitonen, O.5    Uusitupa, M.6
  • 34
    • 45149096836 scopus 로고    scopus 로고
    • Ultrasound-guided peripheral nerve blocks: What are the benefits?
    • Koscielniak-Nielsen ZJ: Ultrasound-guided peripheral nerve blocks: What are the benefits? Acta Anaesthesiol Scand 2008; 52:727-37
    • (2008) Acta Anaesthesiol Scand , vol.52 , pp. 727-737
    • Koscielniak-Nielsen, Z.J.1
  • 35
    • 33845391801 scopus 로고    scopus 로고
    • Use of a nerve stimulator does not improve the efficacy of ultrasound-guided supraclavicular nerve blocks
    • Beach ML, Sites BD, Gallagher JD: Use of a nerve stimulator does not improve the efficacy of ultrasound-guided supraclavicular nerve blocks. J Clin Anesth 2006; 18:580-4
    • (2006) J Clin Anesth , vol.18 , pp. 580-584
    • Beach, M.L.1    Sites, B.D.2    Gallagher, J.D.3
  • 36
    • 33745698190 scopus 로고    scopus 로고
    • Ultrasound- guided interscalene brachial plexus anaesthesia: Differences in success between patients of normal and excessive weight
    • SchwemmerU, PapenfussT, Greim C, BrederlauJ, RoewerN: Ultrasound- guided interscalene brachial plexus anaesthesia: Differences in success between patients of normal and excessive weight. Ultraschall Med 2006; 27:245-50
    • (2006) Ultraschall Med , vol.27 , pp. 245-250
    • Schwemmer, U.1    Papenfuss, T.2    Greim, C.3    Brederlau, J.4    Roewer, N.5
  • 37
    • 38549172004 scopus 로고    scopus 로고
    • Moayeri N, Bigeleisen PE, Groen GJ: Quantitative architecture of the brachial plexus and surrounding compartments, and their possible significance for plexus blocks. ANESTHESIOIOGY 2008; 108:299-304
    • Moayeri N, Bigeleisen PE, Groen GJ: Quantitative architecture of the brachial plexus and surrounding compartments, and their possible significance for plexus blocks. ANESTHESIOIOGY 2008; 108:299-304
  • 38
    • 0141528812 scopus 로고    scopus 로고
    • Finding nerves is not simple
    • Hogan Q: Finding nerves is not simple. Reg Anesth Pain Med 2003; 28:367-71
    • (2003) Reg Anesth Pain Med , vol.28 , pp. 367-371
    • Hogan, Q.1
  • 39
    • 33747354973 scopus 로고    scopus 로고
    • Ultrasound-guided blocks of the ilioinguinal and iliohypogastric nerve: Accuracy of a selective new technique confirmed by anatomical dissection
    • Eichenberger U, Greher M, Kirchmair L, Curatolo M, Moriggl B: Ultrasound-guided blocks of the ilioinguinal and iliohypogastric nerve: Accuracy of a selective new technique confirmed by anatomical dissection. Br J Anaesth 2006;97:238-43
    • (2006) Br J Anaesth , vol.97 , pp. 238-243
    • Eichenberger, U.1    Greher, M.2    Kirchmair, L.3    Curatolo, M.4    Moriggl, B.5
  • 40
    • 0142212364 scopus 로고    scopus 로고
    • Ultrasound-guided supraclavic- ular brachial plexus block
    • Chan V, Perlas A, Rawson R, Odukoya O: Ultrasound-guided supraclavic- ular brachial plexus block. Anesth Analg 2003; 97:1514-7
    • (2003) Anesth Analg , vol.97 , pp. 1514-1517
    • Chan, V.1    Perlas, A.2    Rawson, R.3    Odukoya, O.4
  • 41
    • 35348947950 scopus 로고    scopus 로고
    • Ultrasound characteristics of needles for regional anesthesia
    • Maecken T, Zenz M, Grau T: Ultrasound characteristics of needles for regional anesthesia. Reg Anesth Pain Med 2007; 32:440-7
    • (2007) Reg Anesth Pain Med , vol.32 , pp. 440-447
    • Maecken, T.1    Zenz, M.2    Grau, T.3
  • 42
    • 84893059915 scopus 로고
    • The brachial plexus of nerves in man, the variations in its formation and branches
    • Kerr AT: The brachial plexus of nerves in man, the variations in its formation and branches. Am J Anat 1918; 23:285-395
    • (1918) Am J Anat , vol.23 , pp. 285-395
    • Kerr, A.T.1
  • 44
    • 0024997638 scopus 로고
    • Fasciectomy for treatment of Dupuytren's disease and early complications
    • Am
    • Sennwald GR: Fasciectomy for treatment of Dupuytren's disease and early complications. J Hand Surg [Am] 1990; 15:755-61
    • (1990) J Hand Surg , vol.15 , pp. 755-761
    • Sennwald, G.R.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.