1
-
-
41749096375
-
Quality assurance needs for modern image-based radiotherapy: Recommendations from 2007 interorganizational symposium on "Quality Assurance of Radiation Therapy: Challenges of Advanced Technology."
-
Williamson J.F., Dunscombe P.B., and Sharpe M.B. Quality assurance needs for modern image-based radiotherapy: Recommendations from 2007 interorganizational symposium on "Quality Assurance of Radiation Therapy: Challenges of Advanced Technology.". Int J Radiat Oncol Biol Phys 71 Suppl. 1 (2008) 2-12
-
(2008)
Int J Radiat Oncol Biol Phys
, vol.71
, Issue.SUPPL. 1
, pp. 2-12
-
-
Williamson, J.F.1
Dunscombe, P.B.2
Sharpe, M.B.3
-
2
-
-
41749105314
-
Errors in radiotherapy: Motivation for development of new radiotherapy quality assurance paradigms
-
Fraass BA. Errors in radiotherapy: Motivation for development of new radiotherapy quality assurance paradigms. Int J Radiat Oncol Biol Phys 71 Suppl. 1 (2008) 162-165
-
(2008)
Int J Radiat Oncol Biol Phys
, vol.71
, Issue.SUPPL. 1
, pp. 162-165
-
-
Fraass, BA.1
-
4
-
-
0028230872
-
Comprehensive QA for radiation oncology: Report of AAPM Radiation Therapy Committee Task Group 40
-
Kutcher G.J., Coia L., Gillin M., et al. Comprehensive QA for radiation oncology: Report of AAPM Radiation Therapy Committee Task Group 40. Med Phys 21 (1994) 581-618
-
(1994)
Med Phys
, vol.21
, pp. 581-618
-
-
Kutcher, G.J.1
Coia, L.2
Gillin, M.3
-
5
-
-
41749099277
-
Tools for Developing a Quality Management Program: Proactive Tools (process mapping, value stream mapping, fault tree analysis, and failure mode and effects analysis)
-
Rath F. Tools for Developing a Quality Management Program: Proactive Tools (process mapping, value stream mapping, fault tree analysis, and failure mode and effects analysis). Int J Radiat Oncol Biol Phys 71 Suppl. 1 (2008) 187-190
-
(2008)
Int J Radiat Oncol Biol Phys
, vol.71
, Issue.SUPPL. 1
, pp. 187-190
-
-
Rath, F.1
-
6
-
-
41749098585
-
A method for evaluating quality assurance needs in radiation therapy
-
Huq M.S., Fraass B.A., Dunscombe P.B., et al. A method for evaluating quality assurance needs in radiation therapy. Int J Radiat Oncol Biol Phys 71 Suppl. 1 (2008) 170-173
-
(2008)
Int J Radiat Oncol Biol Phys
, vol.71
, Issue.SUPPL. 1
, pp. 170-173
-
-
Huq, M.S.1
Fraass, B.A.2
Dunscombe, P.B.3
-
7
-
-
67049107499
-
Evaluation of safety in a radiation oncology setting using failure mode and effects analysis
-
Ford E.C., Gaudette R., Myers L., et al. Evaluation of safety in a radiation oncology setting using failure mode and effects analysis. Int J Radiat Oncol Biol Phys 74 (2009) 852-858
-
(2009)
Int J Radiat Oncol Biol Phys
, vol.74
, pp. 852-858
-
-
Ford, E.C.1
Gaudette, R.2
Myers, L.3
-
8
-
-
41749119894
-
Current external beam radiation therapy quality assurance guidance: Does it meet the challenges of emerging image-guided technologies?
-
Palta J.R., Liu C., and Li J.G. Current external beam radiation therapy quality assurance guidance: Does it meet the challenges of emerging image-guided technologies?. Int J Radiat Oncol Biol Phys 71 Suppl. 1 (2008) 13-17
-
(2008)
Int J Radiat Oncol Biol Phys
, vol.71
, Issue.SUPPL. 1
, pp. 13-17
-
-
Palta, J.R.1
Liu, C.2
Li, J.G.3
-
11
-
-
84928096190
-
The shortage of radiotherapy physicists
-
Thomadsen B. The shortage of radiotherapy physicists. J Am Coll Radiol 1 (2004) 280-282
-
(2004)
J Am Coll Radiol
, vol.1
, pp. 280-282
-
-
Thomadsen, B.1
-
12
-
-
56949095284
-
Moving from IMRT QA measurements toward independent computer calculations using control charts
-
Pawlicki T., Yoo S., Court L.E., et al. Moving from IMRT QA measurements toward independent computer calculations using control charts. Radiother Oncol 89 (2008) 330-337
-
(2008)
Radiother Oncol
, vol.89
, pp. 330-337
-
-
Pawlicki, T.1
Yoo, S.2
Court, L.E.3
|