메뉴 건너뛰기




Volumn 7258, Issue , 2009, Pages

Volumetric soft tissue brain imaging on xCAT, a mobile, flat-panel X-ray CT system

Author keywords

Cone beam; Flat panel detector; Mobile; X ray CT

Indexed keywords

BRAIN IMAGING; CONE-BEAM; CT SCAN; FLAT-PANEL DETECTOR; HIGHLY-PORTABLE; INTENSIVE-CARE PATIENTS; MOBILE; NEW SYSTEM; NON-LINEAR; SOFT TISSUE; X-RAY CT; X-RAY CT SYSTEM;

EID: 66749188720     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.811025     Document Type: Conference Paper
Times cited : (11)

References (8)
  • 1
    • 42449136226 scopus 로고    scopus 로고
    • Use of intraoperative CT scanning in endoscopic sinus surgery: A preliminary report
    • March-April
    • Jackman AH, Palmer JN, Chiu AG, Kennedy DW: Use of intraoperative CT scanning in endoscopic sinus surgery: a preliminary report. Am. J. Rhinol., 22(2), March-April 2008.
    • (2008) Am. J. Rhinol. , vol.22 , Issue.2
    • Jackman, A.H.1    Palmer, J.N.2    Chiu, A.G.3    Kennedy, D.W.4
  • 5
    • 4344716167 scopus 로고    scopus 로고
    • Reduction of ring artifacts in high resolution micro-CT reconstructions
    • Sijbers, J., and Postnov, A. Reduction of ring artifacts in high resolution micro-CT reconstructions. Physics in Medicine and Biology, Vol.49, Nr. 14, p. 247-253, (2004)
    • (2004) Physics in Medicine and Biology , vol.49 , Issue.14 , pp. 247-253
    • Sijbers, J.1    Postnov, A.2
  • 6
    • 34347387545 scopus 로고    scopus 로고
    • A post-reconstruction method to correct cupping artifacts in cone beam breast computed tomography
    • Altunbas, M.C., et al., A post-reconstruction method to correct cupping artifacts in cone beam breast computed tomography. Medical Physics, 2007. 34(7): p. 3109-3118.
    • (2007) Medical Physics , vol.34 , Issue.7 , pp. 3109-3118
    • Altunbas, M.C.1
  • 7
    • 85052278301 scopus 로고    scopus 로고
    • Soft-tissue contrast resolution within the head of human cadaver by means of flat-detector-based cone-beam CT
    • San Diego: SPIE
    • Wiegert, J., et al. Soft-tissue contrast resolution within the head of human cadaver by means of flat-detector-based cone-beam CT. in SPIE Medical Imaging. 2004. San Diego: SPIE.
    • (2004) SPIE Medical Imaging
    • Wiegert, J.1
  • 8
    • 0033983855 scopus 로고    scopus 로고
    • An iterative approach to the beam hardening correction in cone beam CT
    • Hsieh, J., et al., An iterative approach to the beam hardening correction in cone beam CT. Medical Physics, 2000. 27(1): p. 23-29.
    • (2000) Medical Physics , vol.27 , Issue.1 , pp. 23-29
    • Hsieh, J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.