메뉴 건너뛰기




Volumn 7258, Issue , 2009, Pages

Modification of the NEMA XR21-2000 cardiac phantom for testing of imaging systems used in endovascular image guided interventions

Author keywords

Cardiac and neurovascular phantom; Digital angiography phantom; Digital subtracted angiography phantom; NEMA XR21

Indexed keywords

ALUMINUM PLATES; CARDIAC AND NEUROVASCULAR PHANTOM; CARDIAC APPLICATIONS; CARDIAC PHANTOM; DIGITAL ANGIOGRAPHY PHANTOM; DIGITAL SUBTRACTED ANGIOGRAPHY PHANTOM; DIGITAL SUBTRACTION ANGIOGRAPHY; ENDOVASCULAR; FLAT PANEL; HUMAN ANATOMY; IMAGE-GUIDED INTERVENTION; IODINE CONCENTRATION; LOWER COST; MULTIPLE APPLICATIONS; NEMA XR21; STANDARD TESTS; X RAY IMAGING SYSTEM;

EID: 66749167156     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.813533     Document Type: Conference Paper
Times cited : (11)

References (10)
  • 3
    • 0032402828 scopus 로고    scopus 로고
    • A comprehensive quality assurance phantom for cardiovascular imaging systems
    • Lin P., "A comprehensive quality assurance phantom for cardiovascular imaging systems," Proc. SPIE 3336, 752-760 (1998).
    • (1998) Proc. SPIE 3336 , pp. 752-760
    • Lin, P.1
  • 4
    • 66749131278 scopus 로고    scopus 로고
    • Composite fluorographic system evaluation
    • Bednarek, D. R., Rudin, S., Yadava, G., Dohatcu, A., "Composite Fluorographic System Evaluation," Med. Phys. 32(6), 2123 (2005).
    • (2005) Med. Phys. , vol.32 , Issue.6 , pp. 2123
    • Bednarek, D.R.1    Rudin, S.2    Yadava, G.3    Dohatcu, A.4
  • 5
    • 66749176593 scopus 로고
    • Performance evaluation and quality assurance in digital subtraction angiography
    • AAPM Report No. 15, Medical Physics Publishing, Madison, WI
    • Report of Digital Radiography/Fluorography Task Group, Diagnostic X-ray Imaging Committee, [Performance Evaluation and Quality Assurance in Digital Subtraction Angiography, AAPM Report No. 15], Medical Physics Publishing, Madison, WI, (1985).
    • (1985) Report of Digital Radiography/Fluorography Task Group, Diagnostic X-ray Imaging Committee
  • 6
    • 0003562238 scopus 로고
    • Standardized methods for measuring diagnostic X-ray exposures
    • AAPM Report No. 31, Medical Physics Publishing, Madison, WI
    • Report of Task Group 8, Diagnostic X-ray Imaging Committee, [Standardized Methods for Measuring Diagnostic XRay Exposures, AAPM Report No. 31], Medical Physics Publishing, Madison, WI, (1990).
    • (1990) Report of Task Group 8, Diagnostic X-ray Imaging Committee
  • 7
    • 0344858310 scopus 로고    scopus 로고
    • Instrumentation requirements of diagnostic radiological physicists (generic listing)
    • AAPM Report No. 60, Medical Physics Publishing, Madison, WI
    • Report of Task Group 4, Diagnostic X-ray Imaging Committee, [Instrumentation Requirements of Diagnostic Radiological Physicists (Generic Listing), AAPM Report No. 60], Medical Physics Publishing, Madison, WI, (1998).
    • (1998) Report of Task Group 4, Diagnostic X-ray Imaging Committee
  • 8
    • 66749120621 scopus 로고    scopus 로고
    • Update on the development of a new dual detector (micro-angiographic fluoroscope/flat panel) c-arm mounted system for endovascular image guided interventions (EIGI)
    • Ionita, C. N., Patel, V., Keleshis, C., Bednarek, D. R., Hoffmann, K. R., Rudin S., "Update on the development of a new dual detector (micro-angiographic fluoroscope/flat panel) c-arm mounted system for endovascular image guided interventions (EIGI)," Med. Phys. 35, 2870 (2008).
    • (2008) Med. Phys. , vol.35 , pp. 2870
    • Ionita, C.N.1    Patel, V.2    Keleshis, C.3    Bednarek, D.R.4    Hoffmann, K.R.5    Rudin, S.6
  • 9
    • 44949138385 scopus 로고    scopus 로고
    • Implementation of a high-sensitivity micro-angiographic fluoroscope (HS-MAF) for in-vivo endovascular image guided interventions (EIGI) and region-of-interest computed tomography (ROI-CT)
    • Ionita, C. N, Keleshis C., Patel V., Yadava G., Hoffmann K. R., Bednarek, D. R., Jain A, Rudin, S., "Implementation of a high-sensitivity micro-angiographic fluoroscope (HS-MAF) for in-vivo endovascular image guided interventions (EIGI) and region-of-interest computed tomography (ROI-CT)," Med. Phys. 6918, 69181I (2008).
    • (2008) Med. Phys. 6918
    • Ionita, C.N.1    Keleshis, C.2    Patel, V.3    Yadava, G.4    Hoffmann, K.R.5    Bednarek, D.R.6    Jain, A.7    Rudin, S.8