메뉴 건너뛰기




Volumn 7258, Issue , 2009, Pages

Noise and signal detection in digital x-ray detectors using the spatial definition of SNR

Author keywords

Coronary; Covariance matrix; Detectability; H matrix; SNR

Indexed keywords

CORONARY; CORONARY ARTERIES; CYLINDRICAL VESSELS; DETECTABILITY; DETECTION PROBABILITIES; DETECTOR RESPONSE; DIGITAL X-RAY DETECTOR; DIGITAL X-RAY IMAGING SYSTEMS; EIGENVALUES AND EIGENVECTORS; ELECTRONIC NOISE; EXPERIMENTAL METHODOLOGY; FOURIER; H MATRIX; HOTELLING OBSERVERS; SHIFT-INVARIANCE; SNR; STATIONARITY;

EID: 66749158088     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.813843     Document Type: Conference Paper
Times cited : (7)

References (11)
  • 1
    • 33745348261 scopus 로고    scopus 로고
    • A practical method for measuring the H matrix of digital x-ray and cone beam CT imaging systems
    • I. S. Kyprianou, A. Badano, B. D. Gallas, S. Park, and K. J. Myers, "A practical method for measuring the H matrix of digital x-ray and cone beam CT imaging systems," Proc. SPIE 6142, pp. 1U1-1U12, 2006.
    • (2006) Proc. SPIE , vol.6142
    • Kyprianou, I.S.1    Badano, A.2    Gallas, B.D.3    Park, S.4    Myers, K.J.5
  • 2
    • 33750944570 scopus 로고    scopus 로고
    • Framework for determination of geometric parameters of a cone beam ct scanner for measuring the system response function and improved object reconstruction
    • ISBI, IEEE, (Washington DC)
    • I. S. Kyprianou, S. Paquerault, B. D. Gallas, A. Badano, S. Park, and K. J. Myers, "Framework for determination of geometric parameters of a cone beam ct scanner for measuring the system response function and improved object reconstruction," in Biomedical Imaging: Macro to Nano. 3rd IEEE International Symposium, pp. 1248 - 1251, ISBI, IEEE, (Washington DC), 2006.
    • (2006) Biomedical Imaging: Macro to Nano. 3rd IEEE International Symposium , pp. 1248-1251
    • Kyprianou, I.S.1    Paquerault, S.2    Gallas, B.D.3    Badano, A.4    Park, S.5    Myers, K.J.6
  • 3
    • 35148827542 scopus 로고    scopus 로고
    • Measuring the point response function of digital x-ray detectors: Comparison between the pinhole and the edge methods
    • M J. Flynn and J. Hsieh, eds., SPIE
    • I. S. Kyprianou, A. Badano, B. D. Gallas, and K. J. Myers, "Measuring the point response function of digital x-ray detectors: comparison between the pinhole and the edge methods," in Medical Imaging 2007: Physics of Medical Imaging, M. J. Flynn and J. Hsieh, eds., 6510, pp. 65100B1-12, SPIE, 2007.
    • (2007) Medical Imaging 2007 , vol.6510
    • Kyprianou, I.S.1    Badano, A.2    Gallas, B.D.3    Myers, K.J.4
  • 4
    • 52949119892 scopus 로고    scopus 로고
    • Singular value description of a digital radiographic detector: Theory and measurements
    • I. Kyprianou, A. Badano, B. Gallas, and K. J. Myers, "Singular value description of a digital radiographic detector: theory and measurements," Med. Phys. 35(35), pp. 4744-4756, 2008.
    • (2008) Med. Phys. , vol.35 , Issue.35 , pp. 4744-4756
    • Kyprianou, I.1    Badano, A.2    Gallas, B.3    Myers, K.J.4
  • 5
    • 3042593291 scopus 로고    scopus 로고
    • Study of the generalized MTF and DQE for a new microangiographic system
    • I. S. Kyprianou, S. Rudin, D. R. Bednarek, and K. R. Hoffmann, "Study of the generalized MTF and DQE for a new microangiographic system," Proc. SPIE 5368, pp. 349-360, 2004.
    • (2004) Proc. SPIE , vol.5368 , pp. 349-360
    • Kyprianou, I.S.1    Rudin, S.2    Bednarek, D.R.3    Hoffmann, K.R.4
  • 6
    • 35148818911 scopus 로고    scopus 로고
    • Tu-c-i-609-08: A total-imagingsystem generalized performance comparison of an x-ray image intensifier and a microangiographic system in neurovascular angiography: Effect of focal spot and scatter
    • G. Yadava, S. Rudin, D. Bednarek, K. Hoffmann, and I. Kyprianou, "Tu-c-i-609-08: A total-imagingsystem generalized performance comparison of an x-ray image intensifier and a microangiographic system in neurovascular angiography: Effect of focal spot and scatter," Medical Physics 32(6), pp. 2080-2081, 2005.
    • (2005) Medical Physics , vol.32 , Issue.6 , pp. 2080-2081
    • Yadava, G.1    Rudin, S.2    Bednarek, D.3    Hoffmann, K.4    Kyprianou, I.5
  • 7
    • 24644455266 scopus 로고    scopus 로고
    • Efficiency of the human observer compared to an ideal observer based on a generalized NEQ which incorporates scatter and geometric unsharpness: Evaluation with a 2AFC experiment
    • M. P. Eckstein and Y. Jiang, eds., Proc. SPIE, SPIE
    • I. S. Kyprianou, A. Ganguly, S. Rudin, D. R. Bednarek, B. D. Gallas, and K. J. Myers, "Efficiency of the human observer compared to an ideal observer based on a generalized NEQ which incorporates scatter and geometric unsharpness: evaluation with a 2AFC experiment," in Medical Imaging 2005: Image Perception, Observer Performance, and Technology Assessment, M. P. Eckstein and Y. Jiang, eds., Proc. SPIE 5749, pp. 251-262, SPIE, 2005.
    • (2005) Medical Imaging : Image Perception, Observer Performance, and Technology Assessment , vol.5749 , pp. 251-262
    • Kyprianou, I.S.1    Ganguly, A.2    Rudin, S.3    Bednarek, D.R.4    Gallas, B.D.5    Myers, K.J.6
  • 8
    • 23844530695 scopus 로고    scopus 로고
    • Generalized performance evaluation of x-ray image intensifier compared with a microangiographic system
    • M J. Flynn, ed.SPIE
    • G. K. Yadava, I. S. Kyprianou, S. Rudin, D. R. Bednarek, and K. R. Hoffmann, "Generalized performance evaluation of x-ray image intensifier compared with a microangiographic system," in Medical Imaging 2005: Physics of Medical Imaging, M. J. Flynn, ed., 5745, pp. 419-429, SPIE, 2005.
    • (2005) Medical Imaging 2005 , vol.5745 , pp. 419-429
    • Yadava, G.K.1    Kyprianou, I.S.2    Rudin, S.3    Bednarek, D.R.4    Hoffmann, K.R.5
  • 9
    • 14644403625 scopus 로고    scopus 로고
    • Generalizing the MTF and DQE to include x-ray scatter and focal spot unsharpness: Application to a new microangiographic system
    • I. S. Kyprianou, S. Rudin, D. R. Bednarek, and K. R. Hoffmann, "Generalizing the MTF and DQE to include x-ray scatter and focal spot unsharpness: Application to a new microangiographic system," Med. Phys. 32(2), pp. 613-626, 2005.
    • (2005) Med. Phys. , vol.32 , Issue.2 , pp. 613-626
    • Kyprianou, I.S.1    Rudin, S.2    Bednarek, D.R.3    Hoffmann, K.R.4
  • 11
    • 0025983265 scopus 로고
    • Null functions and eignefunctions: Tools for the analysis of imaging systems
    • Prog. Clin. Biol. Res.
    • H. H. Barret, J. N. Aarsvold, and T. J. Roney, "Null functions and eignefunctions: Tools for the analysis of imaging systems," in Information Processing in Medical Imaging, 363, pp. 211-226, Prog. Clin. Biol. Res., 1991.
    • (1991) Information Processing in Medical Imaging , vol.363 , pp. 211-226
    • Barret, H.H.1    Aarsvold, J.N.2    Roney, T.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.