메뉴 건너뛰기




Volumn 7258, Issue , 2009, Pages

Use of effective detective quantum efficiency to optimise radiographic exposures for chest imaging with computed radiography

Author keywords

METR; SCAT

Indexed keywords

AIR KERMA; ANTI-SCATTER GRIDS; CHEST IMAGING; CLINICAL PRACTICES; COMPUTED RADIOGRAPHY; DETECTIVE QUANTUM EFFICIENCY; EFFECTIVE DOSE; EXPOSURE CONDITIONS; METR; MODULATION TRANSFER FUNCTION; NOISE EQUIVALENT QUANTA; NOISE-POWER SPECTRA; OPTIMISATION; SCAT; SCATTER FRACTIONS;

EID: 66749147315     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.813650     Document Type: Conference Paper
Times cited : (11)

References (10)
  • 1
    • 62649084844 scopus 로고    scopus 로고
    • An experimental methodology to assess effective DQE (EDQE) of radiographic systems in the presence of scatter and magnification
    • Samei, E., Ranger, N. T., Mackenzie, A., Honey, I. D., Dobbins III, J. T. and Ravin, C. E., "An Experimental Methodology to Assess Effective DQE (EDQE) of Radiographic Systems in the Presence of Scatter and Magnification," Med Phys (submitted)(2009).
    • (2009) Med Phys
    • Samei, E.1    Ranger, N.T.2    Mackenzie, A.3    Honey, I.D.4    Dobbins III, J.T.5    Ravin, C.E.6
  • 2
    • 66749153645 scopus 로고    scopus 로고
    • Medical electrical equipment - characteristics of digital X-ray image devices - Part 1: Determination of the detective quantum efficiency
    • Geneva, Switzerland, IEC
    • IEC, "Medical electrical equipment - characteristics of digital X-ray image devices - Part 1: Determination of the detective quantum efficiency," International Electrotechnical Commission, Geneva, Switzerland, IEC 62220-62221 (2004).
    • (2004) International Electrotechnical Commission , pp. 62220-62221
  • 3
    • 58149181878 scopus 로고    scopus 로고
    • Detector or system? extending the concept of detective quantum efficiency to characterize the performance of digital radiographic imaging systems
    • Samei, E., Ranger, N. T., Mackenzie, A., Honey, I. D., Dobbins, J. T., III and Ravin, C. E., "Detector or System? Extending the Concept of Detective Quantum Efficiency to Characterize the Performance of Digital Radiographic Imaging Systems," Radiology. 249, 926-937 (2008).
    • (2008) Radiology , vol.249 , pp. 926-937
    • Samei, E.1    Ranger, N.T.2    Mackenzie, A.3    Honey, I.D.4    Dobbins III, J.T.5    Ravin, C.E.6
  • 4
    • 0025765012 scopus 로고
    • Quantitative scatter measurement in digital radiography using a photostimulable phosphor imaging system
    • Floyd, C. E., Jr., Lo, J. Y., Chotas, H. G. and Ravin, C. E., "Quantitative Scatter Measurement in Digital Radiography Using a Photostimulable Phosphor Imaging System," Med Phys. 18, 408-413 (1991).
    • (1991) Med Phys. , vol.18 , pp. 408-413
    • Floyd Jr., C.E.1    Lo, J.Y.2    Chotas, H.G.3    Ravin, C.E.4
  • 5
    • 0037038876 scopus 로고    scopus 로고
    • The physics of computed radiography
    • Rowlands, J. A., "The Physics of Computed Radiography," Phys.Med.Biol. 47, R123-R166 (2002).
    • (2002) Phys.Med.Biol. , vol.47
    • Rowlands, J.A.1
  • 6
    • 0031950889 scopus 로고    scopus 로고
    • A method for measuring the presampled MTF of digital radiographic systems using an edge test device
    • Samei, E., Flynn, M. J. and Reimann, D. A., "A Method for Measuring the Presampled MTF of Digital Radiographic Systems Using an Edge Test Device," Med.Phys. 25, 102-113 (1998).
    • (1998) Med.Phys. , vol.25 , pp. 102-113
    • Samei, E.1    Flynn, M.J.2    Reimann, D.A.3
  • 8
    • 14644444480 scopus 로고    scopus 로고
    • Performance comparison of an active matrix flat panel imager, computed radiography system, and a screen-film system at four standard radiation qualities
    • Monnin, P., Gutierrez, D., Bulling, S., Lepori, D., Valley, J. F. and Verdun, F. R., "Performance Comparison of an Active Matrix Flat Panel Imager, Computed Radiography System, and a Screen-Film System at Four Standard Radiation Qualities," Med.Phys. 32, 343-350 (2005).
    • (2005) Med.Phys. , vol.32 , pp. 343-350
    • Monnin, P.1    Gutierrez, D.2    Bulling, S.3    Lepori, D.4    Valley, J.F.5    Verdun, F.R.6
  • 9
    • 0036122063 scopus 로고    scopus 로고
    • An experimental comparison of detector performance for computed radiography systems
    • Samei, E. and Flynn, M. J., "An Experimental Comparison of Detector Performance for Computed Radiography Systems," Med.Phys. 29, 447-459 (2002).
    • (2002) Med.Phys. , vol.29 , pp. 447-459
    • Samei, E.1    Flynn, M.J.2
  • 10
    • 33645520861 scopus 로고    scopus 로고
    • Imaging properties of digital magnification radiography
    • Boyce, S. J. and Samei, E., "Imaging Properties of Digital Magnification Radiography," Med Phys. 33, 984-996 (2006).
    • (2006) Med Phys. , vol.33 , pp. 984-996
    • Boyce, S.J.1    Samei, E.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.