메뉴 건너뛰기




Volumn 7258, Issue , 2009, Pages

Photon-counting CT with silicon detectors: Feasibility for pediatric imaging

Author keywords

Ct; Pediatrics; Photon counting; Silicon

Indexed keywords

ACCELERATION VOLTAGES; ATOMIC NUMBERS; CRYSTALLINE SILICONS; CT; DETECTION EFFICIENCY; FAST CHARGES; HIGH ENERGY X RAY; HIGH-ENERGY RESOLUTION; LOW ENERGIES; MONTE CARLO; NOISE THRESHOLDS; PEDIATRIC IMAGING; PHOTOABSORPTION; PHOTON COUNTING; SCATTERED PHOTONS; SPATIAL RESOLUTION; THIN METALS; X-RAY DETECTOR; X-RAY SPECTRA;

EID: 66749133539     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.813733     Document Type: Conference Paper
Times cited : (13)

References (12)
  • 1
    • 0035139873 scopus 로고    scopus 로고
    • Estimated risks of radiation-induced fatal cancer from pediatric CT
    • D. J. Brenner, C. D. Elliston, E. J. Hall, and W. E. Berdon, "Estimated risks of radiation-induced fatal cancer from pediatric CT," AJR 176, pp. 289-296, 2001.
    • (2001) AJR , vol.176 , pp. 289-296
    • Brenner, D.J.1    Elliston, C.D.2    Hall, E.J.3    Berdon, W.E.4
  • 2
    • 0141993779 scopus 로고    scopus 로고
    • Computed tomography and radiation risks: What pediatric health care providers should know
    • D. P. Frush, L. F. Donnelly, and N. S. Rosen, "Computed tomography and radiation risks: What pediatric health care providers should know," Pediatrics 112, pp. 951-957, 2003.
    • (2003) Pediatrics , vol.112 , pp. 951-957
    • Frush, D.P.1    Donnelly, L.F.2    Rosen, N.S.3
  • 3
    • 36549007486 scopus 로고    scopus 로고
    • Computed tomography - an increasing source of radiation exposure
    • D. J. Brenner and E. J. Hall, "Computed tomography - an increasing source of radiation exposure," N Engl J Med 357, pp. 2277-2284, 2007.
    • (2007) N Engl J Med , vol.357 , pp. 2277-2284
    • Brenner, D.J.1    Hall, E.J.2
  • 5
    • 35348948593 scopus 로고    scopus 로고
    • The medipix3 prototype, a pixel readout chip working in single photon counting mode with improved spectrometric performance
    • R. Ballabriga, M. Campbell, E. H. M. Heijne, X. Llopart, and L. Tlustos, "The medipix3 prototype, a pixel readout chip working in single photon counting mode with improved spectrometric performance," IEEE Trans. Nucl. Science 54(5), 2007.
    • (2007) IEEE Trans. Nucl. Science , vol.54 , pp. 5
    • Ballabriga, R.1    Campbell, M.2    Heijne, E.H.M.3    Llopart, X.4    Tlustos, L.5
  • 6
    • 0026884213 scopus 로고
    • Computed tomography with monochromatic x-rays
    • F. Dilmanian, "Computed tomography with monochromatic x-rays," Am. J. Physiol. Imaging 3, pp. 175-193, 1992.
    • (1992) Am. J. Physiol. Imaging , vol.3 , pp. 175-193
    • Dilmanian, F.1
  • 8
    • 0034244766 scopus 로고    scopus 로고
    • Computer simulations and performance measurements on a silicon strip detector for edge-on imaging
    • M. Lundqvist, B. Cederström, V. Chmill, M. Danielsson, and D. Nygren, "Computer simulations and performance measurements on a silicon strip detector for edge-on imaging," IEEE Trans. Nucl. Science 47(4), pp. 1487-1492, 2000.
    • (2000) IEEE Trans. Nucl. Science , vol.47 , Issue.4 , pp. 1487-1492
    • Lundqvist, M.1    Cederström, B.2    Chmill, V.3    Danielsson, M.4    Nygren, D.5
  • 10
    • 0032821258 scopus 로고    scopus 로고
    • Basic aspects of photon transport through matter with respect to track structure formation
    • B. Grosswendt, "Basic aspects of photon transport through matter with respect to track structure formation," Radiat Environ Biophys 38, pp. 147-161, 1999.
    • (1999) Radiat Environ Biophys , vol.38 , pp. 147-161
    • Grosswendt, B.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.