메뉴 건너뛰기




Volumn 59, Issue 8, 2009, Pages 1603-1609

Instrumental characterization of odour: A combination of olfactory and analytical methods

Author keywords

Analytical odour index; Annoyance; Dimethyl disulphide; GC MS; Sensorial analysis; Volatile substances

Indexed keywords

ANALYTICAL ODOUR INDEX; ANNOYANCE; DIMETHYL DISULPHIDE; GC-MS; SENSORIAL ANALYSIS; VOLATILE SUBSTANCES;

EID: 66649100168     PISSN: 02731223     EISSN: None     Source Type: Book Series    
DOI: 10.2166/wst.2009.125     Document Type: Article
Times cited : (44)

References (22)
  • 4
    • 0023818139 scopus 로고
    • Odour emissions and odour control at wastewater treatment plants in West Germany
    • Frechen, F. B. 1988 Odour emissions and odour control at wastewater treatment plants in West Germany. Water Sci. Technol. 20(4-5), 261-266. (Pubitemid 18260692)
    • (1988) Water Science and Technology , vol.20 , Issue.4-5 , pp. 261-266
    • Frechen, F.-B.1
  • 6
    • 0033867554 scopus 로고    scopus 로고
    • Sewage treatment works odour measurement
    • Gostelow, P. & Parsons, S. A. 2000 Sewage treatment works odour measurement. Water Sci. Technol. 41(6), 33-40. (Pubitemid 30614981)
    • (2000) Water Science and Technology , vol.41 , Issue.6 , pp. 33-40
    • Gostelow, P.1    Parsons, S.A.2
  • 7
    • 0035255275 scopus 로고    scopus 로고
    • Odour measurement for sewage treatment works
    • Gostelow, P., Parsons, S. A. & Stuetz, R. M. 2000 Odour measurement for sewage treatment works. Water Sci. Technol. 35(3), 579-597.
    • (2000) Water Sci. Technol. , vol.35 , Issue.3 , pp. 579-597
    • Gostelow, P.1    Parsons, S.A.2    Stuetz, R.M.3
  • 8
    • 0030164895 scopus 로고    scopus 로고
    • Concentration measurement by dynamic olfactometer
    • Jiang, J. K. 1996 Concentration measurement by dynamic olfactometer. Water Environ. Technol. 8, 55-58.
    • (1996) Water Environ. Technol. , vol.8 , pp. 55-58
    • Jiang, J.K.1
  • 12
    • 0028303686 scopus 로고
    • Perceptual characteristics of binary, trinary, and quaternary odor mixtures consisting of unpleasant constituents
    • DOI 10.1016/0031-9384(94)90264-X
    • Laing, D., Eddy, A. & Best, D. J. 1994 Perceptual characteristics of binary, trinary, and quaternary odor mixtures consisting in unpleasant constituents. Physiol. Behav. 56(1), 81-93. (Pubitemid 24223345)
    • (1994) Physiology and Behavior , vol.56 , Issue.1 , pp. 81-93
    • Laing, D.G.1    Eddy, A.2    Best, D.J.3
  • 13
    • 0000106344 scopus 로고
    • Odor thresholds and irritation levels of several chemical substances: A review
    • Ruth, J. H. 1986 Odor thresholds and irritation levels of several chemical substances: a review. Am. Ind. Assoc. J. 47(3), A142-A151.
    • (1986) Am. Ind. Assoc. J. , vol.47 , Issue.3
    • Ruth, J.H.1
  • 14
    • 77957374606 scopus 로고    scopus 로고
    • Olfactometry and the CEN Standard EN13725
    • Stuetz, R. & Frechen, B. F. (eds) IWA Publishing, London, UK
    • Sneath, R. W. 2001 Olfactometry and the CEN Standard EN13725. In: Stuetz, R. & Frechen, B. F. (eds) Odours in Wastewater Treatment: Measurement, Modelling and Control. IWA Publishing, London, UK.
    • (2001) Odours in Wastewater Treatment: Measurement, Modelling and Control
    • Sneath, R.W.1
  • 15
    • 0032429433 scopus 로고    scopus 로고
    • Sewage odour measurements using a sensory panel and an electronic nose
    • PII S0273122398005599
    • Stuetz, R. M., Engin, G. & Fenner, R. A. 1998 Sewage odour measurements using a sensory panel and an electronic nose. Water Sci. Technol. 38, 331-335. (Pubitemid 128502517)
    • (1998) Water Science and Technology , vol.38 , Issue.3 , pp. 331-335
    • Stuetz, R.M.1    Engin, G.2    Fenner, R.A.3
  • 21
    • 50849102296 scopus 로고    scopus 로고
    • Odour monitoring of small wastewater treatment plant located in sensitive environment
    • Zarra, T., Naddeo, V., Belgiorno, V., Reiser, M. & Kranert, M. 2008 Odour monitoring of small wastewater treatment plant located in sensitive environment. Water Sci. Technol. 58(1), 89-94.
    • (2008) Water Sci. Technol. , vol.58 , Issue.1 , pp. 89-94
    • Zarra, T.1    Naddeo, V.2    Belgiorno, V.3    Reiser, M.4    Kranert, M.5
  • 22
    • 66649125615 scopus 로고    scopus 로고
    • Measurement, management and control of odours in wastewater treatment plants by portable GC-MS
    • 6th-8th July 2008-Rome, Italy
    • Zarra, T., Naddeo, V. & Belgiorno, V. 2008b Measurement, management and control of odours in wastewater treatment plants by portable GC-MS. NOSE2008, 6th-8th July 2008-Rome, Italy.
    • (2008) NOSE2008
    • Zarra, T.1    Naddeo, V.2    Belgiorno, V.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.