-
1
-
-
0018104133
-
The problem of valve prosthesis-patient mismatch
-
Rahimtoola SH. The problem of valve prosthesis-patient mismatch. Circulation 1978;58:20-24 (Pubitemid 8376654)
-
(1978)
Circulation
, vol.58
, Issue.1
, pp. 20-24
-
-
Rahimtoola, S.H.1
-
2
-
-
0042859863
-
Impact of valve prosthesis-patient mismatch on short-term mortality after aortic valve replacement
-
DOI 10.1161/01.CIR.0000085167.67105.32
-
Blais C, Dumesnil JG, Baillot R, et al. Impact of valve prosthesis-patient mismatch on short-term mortality after aortic valve replacement. Circulation 2003;108:983-988 ▶ Most of the evidence regarding the negative impact of mismatch in the aortic position comes from this study. (Pubitemid 37048229)
-
(2003)
Circulation
, vol.108
, Issue.8
, pp. 983-988
-
-
Blais, C.1
Dumesnil, J.G.2
Baillot, R.3
Simard, S.4
Doyle, D.5
Pibarot, P.6
-
3
-
-
33744947842
-
Patient-prosthesis mismatch does not affect survival following aortic valve replacement
-
DOI 10.1016/j.ejcts.2006.03.046, PII S1010794006003587
-
Howell NJ, Keogh BE, Barnet V, et al. Patient-prosthesis mismatch does not affect survival following aortic valve replacement. Eur J Cardiothorac Surg 2006;30:10-14 (Pubitemid 43850318)
-
(2006)
European Journal of Cardio-thoracic Surgery
, vol.30
, Issue.1
, pp. 10-14
-
-
Howell, N.J.1
Keogh, B.E.2
Barnet, V.3
Bonser, R.S.4
Graham, T.R.5
Rooney, S.J.6
Wilson, I.C.7
Pagano, D.8
-
4
-
-
56749165459
-
Moderate patient-prosthesis mismatch after valve replacement for severe aortic stenosis has no impact on short-term and long-term mortality
-
Mascherbauer J, Rosenhek R, Fuchs C, et al. Moderate patient-prosthesis mismatch after valve replacement for severe aortic stenosis has no impact on short-term and long-term mortality. Heart 2008;94:1639-1645
-
(2008)
Heart
, vol.94
, pp. 1639-1645
-
-
Mascherbauer, J.1
Rosenhek, R.2
Fuchs, C.3
-
5
-
-
35948945665
-
Low-gradient aortic stenosis: Impact of prosthesis-patient mismatch on survival
-
DOI 10.1093/eurheartj/ehm393
-
Monin JL, Monchi M, Kirsch ME, et al. Low-gradient aortic stenosis: impact of prosthesis-patient mismatch on survival. Eur Heart J 2007;28:2620-2626 ▶ This, together with reference 9, is one of the two studies addressing the issue of mismatch in the setting of low flow/low gradient aortic stenosis. (Pubitemid 350071524)
-
(2007)
European Heart Journal
, vol.28
, Issue.21
, pp. 2620-2626
-
-
Monin, J.-L.1
Monchi, M.2
Kirsch, M.E.W.3
Petit-Eisenmann, H.4
Baleynaud, S.5
Chauvel, C.6
Metz, D.7
Adams, C.8
Quere, J.-P.9
Gueret, P.10
Tribouilloy, C.11
-
6
-
-
34147119634
-
Impact of prosthesis-patient mismatch on survival after mitral valve replacement
-
DOI 10.1161/CIRCULATIONAHA.106.631549
-
Magne J, Mathieu P, Dumesnil JG, et al. Impact of prosthesis-patient mismatch on survival after mitral valve replacement. Circulation 2007;115:1417-1425 ▶ This is the main study addressing the issue of mismatch in the mitral position. (Pubitemid 46648377)
-
(2007)
Circulation
, vol.115
, Issue.11
, pp. 1417-1425
-
-
Magne, J.1
Mathieu, P.2
Dumesnil, J.G.3
Tanne, D.4
Dagenais, F.5
Doyle, D.6
Pibarot, P.7
-
7
-
-
34249085123
-
The impact of patient-prosthesis mismatch on late outcomes after mitral valve replacement
-
DOI 10.1016/j.jtcvs.2006.12.071, PII S0022522307003583
-
Lam BK, Chan V, Hendry P, et al. The impact of patient-prosthesis mismatch on late outcomes after mitral valve replacement. J Thorac Cardiovasc Surg 2007;133:1464-1473 (Pubitemid 46802613)
-
(2007)
Journal of Thoracic and Cardiovascular Surgery
, vol.133
, Issue.6
-
-
Lam, B.-K.1
Chan, V.2
Hendry, P.3
Ruel, M.4
Masters, R.5
Bedard, P.6
Goldstein, B.7
Rubens, F.8
Mesana, T.9
-
8
-
-
34548124741
-
Patient-prosthesis mismatch after mitral valve replacement: Myth or reality?
-
Totaro P, Argano V. Patient-prosthesis mismatch after mitral valve replacement: myth or reality? J Thorac Cardiovasc Surg 2007;134:697-701.
-
(2007)
J Thorac Cardiovasc Surg
, vol.134
, pp. 697-701
-
-
Totaro, P.1
Argano, V.2
-
9
-
-
33747199079
-
Long-term outcomes after valve replacement for low-gradient aortic stenosis: Impact of prosthesis-patient mismatch
-
DOI 10.1161/CIRCULATIONAHA.105.001180, PII 0000301720060704100090
-
Kulik A, Burwash IG, Kapila V, et al. Long-term outcomes after valve replacement for low-gradient aortic stenosis: impact of prosthesis-patient mismatch. Circulation 2006;114:I553-8. (Pubitemid 44297207)
-
(2006)
Circulation
, vol.114
, Issue.SUPPL. 1
-
-
Kulik, A.1
Burwash, I.G.2
Kapila, V.3
Mesana, T.G.4
Ruel, M.5
-
10
-
-
33646205280
-
Prosthesis-patient mismatch after aortic valve replacement predominantly affects patients with preexisting left ventricular dysfunction: Effect on survival, freedom from heart failure, and left ventricular mass regression
-
Ruel M, Al-Faleh H, Kulik A, et al. Prosthesis-patient mismatch after aortic valve replacement predominantly affects patients with preexisting left ventricular dysfunction: effect on survival, freedom from heart failure, and left ventricular mass regression. J Thorac Cardiovasc Surg 2006;131:1036-1044
-
(2006)
J Thorac Cardiovasc Surg
, vol.131
, pp. 1036-1044
-
-
Ruel, M.1
Al-Faleh, H.2
Kulik, A.3
-
11
-
-
33644858444
-
Impact of prosthesis-patient mismatch on cardiac events and midterm mortality after aortic valve replacement in patients with pure aortic stenosis
-
DOI 10.1161/CIRCULATIONAHA.105.587022, PII 0000301720060131000016
-
Tasca G, Mhagna Z, Perotti S, et al. Impact of prosthesis-patient mismatch on cardiac events and midterm mortality after aortic valve replacement in patients with pure aortic stenosis. Circulation 2006;113:570-576 (Pubitemid 43754358)
-
(2006)
Circulation
, vol.113
, Issue.4
, pp. 570-576
-
-
Tasca, G.1
Mhagna, Z.2
Perotti, S.3
Centurini, P.B.4
Sabatini, T.5
Amaducci, A.6
Brunelli, F.7
Cirillo, M.8
Tomba, M.D.9
Quiani, E.10
Troise, G.11
Pibarot, P.12
-
12
-
-
33745044871
-
Patient prosthesis mismatch affects short- And long-term outcomes after aortic valve replacement
-
DOI 10.1016/j.ejcts.2006.04.007, PII S1010794006004118
-
Walther T, Rastan A, Falk V, et al. Patient prosthesis mismatch affects short- and long-term outcomes after aortic valve replacement. Eur J Cardiothorac Surg 2006;30:15-19 (Pubitemid 44183638)
-
(2006)
European Journal of Cardio-thoracic Surgery
, vol.30
, Issue.1
, pp. 15-19
-
-
Walther, T.1
Rastan, A.2
Falk, V.3
Lehmann, S.4
Garbade, J.5
Funkat, A.K.6
Mohr, F.W.7
Gummert, J.F.8
-
13
-
-
31044436430
-
Prosthesis-patient mismatch after aortic valve replacement: Impact of age and body size on late survival
-
DOI 10.1016/j.athoracsur.2005.07.084, PII S0003497505013640
-
Moon MR, Pasque MK, Munfakh NA, et al. Prosthesis-patient mismatch after aortic valve replacement: impact of age and body size on late survival. Ann Thorac Surg 2006;81:481-8; discussion 489. (Pubitemid 43120540)
-
(2006)
Annals of Thoracic Surgery
, vol.81
, Issue.2
, pp. 481-489
-
-
Moon, M.R.1
Pasque, M.K.2
Munfakh, N.A.3
Melby, S.J.4
Lawton, J.S.5
Moazami, N.6
Codd, J.E.7
Crabtree, T.D.8
Barner, H.B.9
Damiano Jr., R.J.10
-
14
-
-
0036266543
-
Patient prosthesis mismatch is rare after aortic valve replacement: Valve size may be irrelevant
-
DOI 10.1016/S0003-4975(02)03582-8, PII S0003497502035828
-
Hanayama N, Christakis GT, Mallidi HR, et al. Patient prosthesis mismatch is rare after aortic valve replacement: valve size may be irrelevant. Ann Thorac Surg 2002;73:1822-9; discussion 1829. ▶ Most of the controversy regarding the impact of mismatch in the aortic position comes from this prospective study, based on actual individual EOA measurements obtained from postoperative echocardiography. (Pubitemid 34596724)
-
(2002)
Annals of Thoracic Surgery
, vol.73
, Issue.6
, pp. 1822-1829
-
-
Hanayama, N.1
Christakis, G.T.2
Mallidi, H.R.3
Joyner, C.D.4
Fremes, S.E.5
Morgan, C.D.6
Mitoff, P.R.R.7
Goldman, B.S.8
-
15
-
-
0141742218
-
Prosthesis size and long-term survival after aortic valve replacement
-
DOI 10.1016/S0022-5223(03)00591-9
-
Blackstone EH, Cosgrove DM, Jamieson WR, et al. Prosthesis size and long-term survival after aortic valve replacement. J Thorac Cardiovasc Surg 2003;126:783-796 (Pubitemid 37151965)
-
(2003)
Journal of Thoracic and Cardiovascular Surgery
, vol.126
, Issue.3
, pp. 783-796
-
-
Blackstone, E.H.1
Cosgrove, D.M.2
Jamieson, W.R.E.3
Birkmeyer, N.J.4
Lemmer Jr., J.H.5
Miller, D.C.6
Butchart, E.G.7
Rizzoli, G.8
Yacoub, M.9
Chai, A.10
Adams, D.H.11
Rao, V.12
He, G.-W.13
Cooley, D.A.14
-
16
-
-
33746393625
-
Prosthesis-patient mismatch: Definition, clinical impact, and prevention
-
DOI 10.1136/hrt.2005.067363
-
Pibarot P, Dumesnil JG. Prosthesis-patient mismatch: definition, clinical impact, and prevention. Heart 2006;92:1022-1029 (Pubitemid 44125207)
-
(2006)
Heart
, vol.92
, Issue.8
, pp. 1022-1029
-
-
Pibarot, P.1
Dumesnil, J.G.2
-
17
-
-
44249113574
-
Impact of valve prosthesis-patient mismatch estimated by echocardiographic-determined effective orifice area on long-term outcome after aortic valve replacement
-
Florath I, Albert A, Rosendahl U, et al. Impact of valve prosthesis-patient mismatch estimated by echocardiographic-determined effective orifice area on long-term outcome after aortic valve replacement. Am Heart J 2008;155:1135-1142
-
(2008)
Am Heart J
, vol.155
, pp. 1135-1142
-
-
Florath, I.1
Albert, A.2
Rosendahl, U.3
-
18
-
-
10744233320
-
Late incidence and predictors of persistent or recurrent heart failure in patients with aortic prosthetic valves
-
DOI 10.1016/j.jtcvs.2003.07.043
-
Ruel M, Rubens FD, Masters RG, et al. Late incidence and predictors of persistent or recurrent heart failure in patients with aortic prosthetic valves. J Thorac Cardiovasc Surg 2004;127:149-159 (Pubitemid 38160478)
-
(2004)
Journal of Thoracic and Cardiovascular Surgery
, vol.127
, Issue.1
, pp. 149-159
-
-
Ruel, M.1
Rubens, F.D.2
Masters, R.G.3
Pipe, A.L.4
Bedard, P.5
Hendry, P.J.6
Lam, B.K.7
Burwash, I.G.8
Goldstein, W.G.9
Brais, M.P.10
Keon, W.J.11
Mesana, T.G.12
Gillinov, A.M.13
Azar, H.14
-
19
-
-
0034619384
-
Prosthesis-patient mismatch affects survival after aortic valve replacement
-
Rao V, Jamieson WR, Ivanov J, et al. Prosthesis-patient mismatch affects survival after aortic valve replacement. Circulation 2000;102:III5-9.
-
(2000)
Circulation
, vol.102
-
-
Rao, V.1
Jamieson, W.R.2
Ivanov, J.3
-
21
-
-
33644870470
-
Impact of prosthesis-patient mismatch on long-term survival in patients with small St Jude medical mechanical prostheses in the aortic position
-
DOI 10.1161/CIRCULATIONAHA.105.546754, PII 0000301720060124000015
-
Mohty D, Malouf JF, Girard SE, et al. Impact of prosthesis-patient mismatch on long-term survival in patients with small St Jude Medical mechanical prostheses in the aortic position. Circulation 2006;113:420-426 (Pubitemid 43803204)
-
(2006)
Circulation
, vol.113
, Issue.3
, pp. 420-426
-
-
Mohty-Echahidi, D.1
Malouf, J.F.2
Girard, S.E.3
Schaff, H.V.4
Grill, D.E.5
Enriquez-Sarano, M.E.6
Miller Jr., F.A.7
-
22
-
-
21044431634
-
Impact of prosthesis-patient size on functional recovery after aortic valve replacement
-
DOI 10.1161/CIRCULATIONAHA.104.505248
-
Koch CG, Khandwala F, Estafanous FG, et al. Impact of prosthesis-patient size on functional recovery after aortic valve replacement. Circulation 2005;111:3221-3229 (Pubitemid 40874993)
-
(2005)
Circulation
, vol.111
, Issue.24
, pp. 3221-3229
-
-
Koch, C.G.1
Khandwala, F.2
Estafanous, F.G.3
Loop, F.D.4
Blackstone, E.H.5
-
23
-
-
37249039292
-
Enlargement of the small aortic root during aortic valve replacement: Is there a benefit?
-
Kulik A, Al-Saigh M, Chan V, et al. Enlargement of the small aortic root during aortic valve replacement: is there a benefit? Ann Thorac Surg 2008;85:94-100.
-
(2008)
Ann Thorac Surg
, vol.85
, pp. 94-100
-
-
Kulik, A.1
Al-Saigh, M.2
Chan, V.3
-
24
-
-
45449105221
-
Does the use of stentless aortic valves in a subcoronary position prevent patient-prosthesis mismatch for small aortic annulus?
-
Lopez S, Mathieu P, Pibarot P, et al. Does the use of stentless aortic valves in a subcoronary position prevent patient-prosthesis mismatch for small aortic annulus? J Card Surg 2008;23:331-335
-
(2008)
J Card Surg
, vol.23
, pp. 331-335
-
-
Lopez, S.1
Mathieu, P.2
Pibarot, P.3
-
25
-
-
34250311155
-
Meta-Analysis of Valve Hemodynamics and Left Ventricular Mass Regression for Stentless Versus Stented Aortic Valves
-
DOI 10.1016/j.athoracsur.2007.02.057, PII S0003497507004146
-
Kunadian B, Vijayalakshmi K, Thornley AR, et al. Meta-analysis of valve hemodynamics and left ventricular mass regression for stentless versus stented aortic valves. Ann Thorac Surg 2007;84:73-78 (Pubitemid 46921121)
-
(2007)
Annals of Thoracic Surgery
, vol.84
, Issue.1
, pp. 73-78
-
-
Kunadian, B.1
Vijayalakshmi, K.2
Thornley, A.R.3
De Belder, M.A.4
Hunter, S.5
Kendall, S.6
Graham, R.7
Stewart, M.8
Thambyrajah, J.9
Dunning, J.10
|