Volumn 45, Issue 6, 2009, Pages 2784-2787

An experimental study of stable operating conditions for a high-sensitivity induction gradiometer

Author keywords

Electrical interferences; Faraday cage; Grounding; Induction gradiometer

Indexed keywords

ELECTRICAL ENGINEERING; MAGNETIC MATERIALS;

EID: 66549092617     PISSN: 00189464     EISSN: None     Source Type: Journal    
DOI: 10.1109/TMAG.2009.2020561     Document Type: Article
Times cited : (3)

References (12)
  • 1
    • 0019066684 scopus 로고
    • A portable low-noise low-frequency 3-axis search coil magnetometer
    • S. A. Macintyre, "A portable low-noise low-frequency 3-axis search coil magnetometer," IEEE Trans. Magn., vol. 16, pp. 761-763, 1980.
    • (1980) IEEE Trans. Magn , vol.16 , pp. 761-763
    • Macintyre, S.A.1
  • 2
    • 0020197283 scopus 로고
    • Air-core induction-coil magnetometer design
    • K. P. Estola and J. Malmivuo, "Air-core induction-coil magnetometer design," J. Phys. E-Sci. Instrum., vol. 15, pp. 1110-1113, 1982.
    • (1982) J. Phys. E-Sci. Instrum , vol.15 , pp. 1110-1113
    • Estola, K.P.1    Malmivuo, J.2
  • 3
    • 0042878579 scopus 로고    scopus 로고
    • Compact room-temperature induction magnetometer with superconducting quantum interference device level field sensitivity
    • Aug
    • R. J. Prance, T. D. Clark, and H. Prance, "Compact room-temperature induction magnetometer with superconducting quantum interference device level field sensitivity," Rev. Sci. Instrum., vol. 74, pp. 3735-3739, Aug. 2003.
    • (2003) Rev. Sci. Instrum , vol.74 , pp. 3735-3739
    • Prance, R.J.1    Clark, T.D.2    Prance, H.3
  • 4
    • 34247180231 scopus 로고    scopus 로고
    • Induction coil sensors - A review
    • Mar
    • S. Tumanski, "Induction coil sensors - A review," Meas. Sci. Technol., vol. 18, pp. R31-R46, Mar. 2007.
    • (2007) Meas. Sci. Technol , vol.18
    • Tumanski, S.1
  • 6
    • 66549106254 scopus 로고    scopus 로고
    • Reduction of RF noise for stable SQUID sensor operation inside a cylindrical magnetic shield
    • K. Tashiro, I. Sasada, K. Yoshitomi, and K. Kazami, "Reduction of RF noise for stable SQUID sensor operation inside a cylindrical magnetic shield," JSAEM Studies Appl. Electromagn. Mech., vol. 14, pp. 249-256, 2003.
    • (2003) JSAEM Studies Appl. Electromagn. Mech , vol.14 , pp. 249-256
    • Tashiro, K.1    Sasada, I.2    Yoshitomi, K.3    Kazami, K.4
  • 8
    • 66549104979 scopus 로고    scopus 로고
    • Development of induction gradiometer for magnetocardiography
    • in Japanese
    • A. Kakiuchi, A. Matsuoka, K. Tashiro, and H. Wakiwaka, "Development of induction gradiometer for magnetocardiography," in Proc. of SEAD20 (in Japanese), 2008, pp. 519-522.
    • (2008) Proc. of SEAD20 , pp. 519-522
    • Kakiuchi, A.1    Matsuoka, A.2    Tashiro, K.3    Wakiwaka, H.4
  • 9
    • 34250773857 scopus 로고    scopus 로고
    • Optimal design of an air-core induction magnetometer for detecting low-frequency fields of less than 1 pT
    • K. Tashiro, "Optimal design of an air-core induction magnetometer for detecting low-frequency fields of less than 1 pT," J. Magn. Soc. Jpn., vol. 30, pp. 439-442, 2006.
    • (2006) J. Magn. Soc. Jpn , vol.30 , pp. 439-442
    • Tashiro, K.1
  • 10
    • 50149108181 scopus 로고    scopus 로고
    • Proposal of coil structure for air-core induction magnetometer
    • K. Tashiro, "Proposal of coil structure for air-core induction magnetometer," in Proc. IEEE Sensor 2006, pp. 939-942.
    • (2006) Proc. IEEE Sensor , pp. 939-942
    • Tashiro, K.1
  • 11
    • 66549100270 scopus 로고    scopus 로고
    • K. Tashiro, Broadband air-core Brooks-coil induction magnetometer, in SICE - ICCAS 2006, 2006, TA07-2, p. 4.
    • K. Tashiro, "Broadband air-core Brooks-coil induction magnetometer," in SICE - ICCAS 2006, 2006, vol. TA07-2, p. 4.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.