Volumn , Issue , 2007, Pages 214-217

Numerical simulation of biochemical behaviour of biosensors with perforated membrane

Author keywords

Biosensors; Modelling; Reaction diffusion; Simulation

Indexed keywords

DIFFUSION IN LIQUIDS; ENZYMES; LINEAR EQUATIONS; MODELS; NONLINEAR EQUATIONS; NUMERICAL MODELS;

EID: 66549088304     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.7148/2007-0214     Document Type: Conference Paper
Times cited : (4)

References (13)
  • 1
    • 16544365974 scopus 로고    scopus 로고
    • A generic sandwich-type biosensor with nanomolar detection limits
    • DOI 10.1007/s00216-003-2466-0
    • Baeumner, A. J.; C. Jones; C.Y. Wong and A. Price. 2004. "A Generic Sandwich-type Biosensor with Nanomolar Detection Limits". Analytical and Bioanalytical Chemistry 378, No. 6, 1587-1593. (Pubitemid 40877691)
    • (2004) Analytical and Bioanalytical Chemistry , vol.378 , Issue.6 , pp. 1587-1593
    • Baeumner, A.J.1    Jones, C.2    Wong, C.Y.3    Price, A.4
  • 2
    • 3142713645 scopus 로고    scopus 로고
    • The influence of the enzyme membrane thickness on the response of amperometric biosensors
    • Baronas, R.; F. Ivanauskas and J. Kulys. 2003. "The Influence of the Enzyme Membrane Thickness on the Response of Amperometric Biosensors". Sensors 3, No. 7, 248-262. (Pubitemid 40643547)
    • (2003) Sensors , vol.3 , Issue.7 , pp. 248-262
    • Baronas, R.1    Ivanauskas, F.2    Kulys, J.3
  • 3
    • 3142731382 scopus 로고    scopus 로고
    • The effect of diffusion limitations on the response of amperometric biosensors with substrate cyclic conversion
    • DOI 10.1023/B:JOMC.0000033256.70413.f7
    • Baronas, R.; F. Ivanauskas and J. Kulys. 2004. "The Effect of Diffusion Limitations on the Response of Amperometric Biosensors with Substrate Cyclic Conversion". Journal of Mathematical Chemistry, 35, No. 3, 199-213. (Pubitemid 38918913)
    • (2004) Journal of Mathematical Chemistry , vol.35 , Issue.3 , pp. 199-213
    • Baronas, R.1    Ivanauskas, F.2    Kulys, J.3
  • 4
    • 33644868608 scopus 로고    scopus 로고
    • Computational modelling of biosensors with perforated and selective membranes
    • DOI 10.1007/s10910-005-9034-0
    • Baronas, R.; J. Kulys and F. Ivanauskas. 2006. "Computational Modelling of Biosensors with Perforated and Selective Membranes". Journal of Mathematical Chemistry 39, No. 2, 345-362. (Pubitemid 43375529)
    • (2006) Journal of Mathematical Chemistry , vol.39 , Issue.2 , pp. 345-362
    • Baronas, R.1    Kulys, J.2    Ivanauskas, F.3
  • 8
    • 0029044840 scopus 로고
    • Biosensors for environmental applications
    • Rogers, K.R. 1995. "Biosensors for Environmental Applications". Biosensors and Bioelectronics 10, No. 6-7, 533-541.
    • (1995) Biosensors and Bioelectronics , vol.10 , Issue.6-7 , pp. 533-541
    • Rogers, K.R.1
  • 11
    • 0027318160 scopus 로고
    • Mathematical modelling of amperometric enzyme electrodes with perforated membranes
    • DOI 10.1016/0956-5663(93)80055-T
    • Schulmeister, T. and D. Pfeiffer. 1993. "Mathematical Modelling of Amperometric Enzyme Electrodes with Perforated Membranes. Biosensors Bioelectronics 8, No. 2, 75-79. (Pubitemid 23158719)
    • (1993) Biosensors and Bioelectronics , vol.8 , Issue.2 , pp. 75-79
    • Schulmeister, T.1    Pfeiffer, D.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.