메뉴 건너뛰기




Volumn 8, Issue 1, 2009, Pages 1-11

Analysis of electromagnetic pollution produced by line frequency coreless induction furnaces

Author keywords

Harmonics; Induction furnace; Power quality measurement; Unbalance

Indexed keywords

ELECTRO MAGNETIC POLLUTION; FURNACE INSTALLATION; FURNACE TRANSFORMERS; HARMONICS; HARMONICS AND INTERHARMONICS; INDUCTION FURNACE; LINE FREQUENCY; OPTIMIZATION METHOD; PHASE VOLTAGE; POWER QUALITY MEASUREMENT; POWER SUPPLY NETWORKS; UNBALANCE;

EID: 66349126968     PISSN: 11092777     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (14)

References (16)
  • 2
    • 66349106316 scopus 로고    scopus 로고
    • Power Quality for Induction Melting in Metal Production
    • Electric Power Research Institute, U.S.A
    • V. Rudnev, D. Loveless, R. Cook, M. Black, Power Quality for Induction Melting in Metal Production, TechCommentary Electric Power Research Institute, U.S.A., 1999.
    • (1999) TechCommentary
    • Rudnev, V.1    Loveless, D.2    Cook, R.3    Black, M.4
  • 6
    • 66349132571 scopus 로고    scopus 로고
    • F. Lattarulo Editor, Elsevier Science&Technology Books
    • F. Lattarulo (Editor), Electromagnetic Compatibility in Power System, Elsevier Science&Technology Books, 2006.
    • (2006) Electromagnetic Compatibility in Power System
  • 8
    • 54949118719 scopus 로고    scopus 로고
    • Using Simulation for Study the Possibility of Canceling Load Unbalance of Non-sinusoidal High Power three-phase Loads
    • M. Panoiu, C. Panoiu, I. Sora, A. Iordan, R. Rob, Using Simulation for Study the Possibility of Canceling Load Unbalance of Non-sinusoidal High Power three-phase Loads, WSEAS Transactions on Systems, Vol. 7, Issue 7, 2008, pp. 699-710.
    • (2008) WSEAS Transactions on Systems , vol.7 , Issue.7 , pp. 699-710
    • Panoiu, M.1    Panoiu, C.2    Sora, I.3    Iordan, A.4    Rob, R.5
  • 9
    • 66349136666 scopus 로고    scopus 로고
    • Harmonic Estimation in Power Systems Using Adaptive Perceptrons Based on a Genetic Algorithm
    • S. G. Seifossadat, M. Razzaz, M. Moghaddasian, M. Monadi, Harmonic Estimation in Power Systems Using Adaptive Perceptrons Based on a Genetic Algorithm, WSEAS Transactions on Power Systems, Vol. 2, Issue 11, 2007, pp. 239-244.
    • (2007) WSEAS Transactions on Power Systems , vol.2 , Issue.11 , pp. 239-244
    • Seifossadat, S.G.1    Razzaz, M.2    Moghaddasian, M.3    Monadi, M.4
  • 10
    • 54949130011 scopus 로고    scopus 로고
    • Harmonic Mitigation of Residential Distribution System using a Novel Hybrid Active Power Filter
    • Yang Han, Gang Yao, Li-Dan Zhou, Chen Chen, Harmonic Mitigation of Residential Distribution System using a Novel Hybrid Active Power Filter, WSEAS Transactions on Power Systems, Vol. 2, Issue 12, 2007, pp. 255-260.
    • (2007) WSEAS Transactions on Power Systems , vol.2 , Issue.12 , pp. 255-260
    • Han, Y.1    Yao, G.2    Zhou, L.-D.3    Chen, C.4
  • 11
    • 66349100272 scopus 로고    scopus 로고
    • Harmonic Distortion and Reactive Power Compensation in Single Phase Power Systems using Orthogonal Transformation Strategy
    • W. Hosny, B. Dobrucky, Harmonic Distortion and Reactive Power Compensation in Single Phase Power Systems using Orthogonal Transformation Strategy, WSEAS Transactions on Power Systems, Vol. 3, Issue 4, 2008, pp. 237-246.
    • (2008) WSEAS Transactions on Power Systems , vol.3 , Issue.4 , pp. 237-246
    • Hosny, W.1    Dobrucky, B.2
  • 12
    • 66349102902 scopus 로고    scopus 로고
    • Optimal Size and Location of Capacitors Placed on a Distribution System
    • Ching-Tzong Su, Chen-Yi Lin, Ji-Jen Wong, Optimal Size and Location of Capacitors Placed on a Distribution System, WSEAS Transactions on Power Systems, Vol. 3, Issue 4, 2008, pp. 247-256.
    • (2008) WSEAS Transactions on Power Systems , vol.3 , Issue.4 , pp. 247-256
    • Su, C.-T.1    Lin, C.-Y.2    Wong, J.-J.3
  • 14
    • 66349115152 scopus 로고    scopus 로고
    • Ching-Tzong Su, Chen-Yi Lin, Ji-Jen Wong, IEC 61000-3-4, EMC, Part 3-4: Limits - Limitation of Emission of Harmonic Currents in Low-Voltage Power Supply Systems for Equipment with Rated Current Greater than 16A, 1998.
    • Ching-Tzong Su, Chen-Yi Lin, Ji-Jen Wong, IEC 61000-3-4, EMC, Part 3-4: Limits - Limitation of Emission of Harmonic Currents in Low-Voltage Power Supply Systems for Equipment with Rated Current Greater than 16A, 1998.
  • 15
    • 42249113813 scopus 로고    scopus 로고
    • Optimum Control of Selective and Total Harmonic Distortion in Current and Voltage Under Nonsinusoidal Conditions
    • S. George, V. Agarwal, Optimum Control of Selective and Total Harmonic Distortion in Current and Voltage Under Nonsinusoidal Conditions, IEEE Transactions on Power Delivery, Vol.23, Issue 2, 2008, pp.937-944.
    • (2008) IEEE Transactions on Power Delivery , vol.23 , Issue.2 , pp. 937-944
    • George, S.1    Agarwal, V.2
  • 16
    • 42249091865 scopus 로고    scopus 로고
    • Optimal Reactive Compensators in Power Systems Under Asymmetrical and Nonsinusoidal Conditions
    • T.B Sekara, J.C. Mikulovic, Z.R. Djurisic, Optimal Reactive Compensators in Power Systems Under Asymmetrical and Nonsinusoidal Conditions, IEEE Transactions on Power Delivery, Vol.23, Issue 2, 2008, pp.974-984.
    • (2008) IEEE Transactions on Power Delivery , vol.23 , Issue.2 , pp. 974-984
    • Sekara, T.B.1    Mikulovic, J.C.2    Djurisic, Z.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.