메뉴 건너뛰기




Volumn 119, Issue 5, 2009, Pages 959-963

A coated electrode carrier for cochlear implantation reduces insertion forces

Author keywords

Coating; Cochlear implant; Drug delivery; Hearing preservation; Insertion forces

Indexed keywords

ARTICLE; BIODEGRADABLE IMPLANT; COCHLEA PROSTHESIS; DRUG DELIVERY SYSTEM; ELECTRODE; HUMAN; MATERIAL COATING; PRIORITY JOURNAL; SCALA TYMPANI; TEMPORAL BONE; IMPLANTATION; INSTRUMENTATION; MATERIALS TESTING; PROSTHESIS;

EID: 66349107958     PISSN: 0023852X     EISSN: None     Source Type: Journal    
DOI: 10.1002/lary.20206     Document Type: Article
Times cited : (30)

References (10)
  • 1
    • 0027248538 scopus 로고
    • Intracochlear placement of cochlear implant electrodes in soft surgery technique
    • Lehnhardt E. Intracochlear placement of cochlear implant electrodes in soft surgery technique. HNO 1993; 41: 356-359.
    • (1993) HNO , vol.41 , pp. 356-359
    • Lehnhardt, E.1
  • 2
    • 3242718845 scopus 로고    scopus 로고
    • Development and evaluation of an improved cochlear implant electrode design for electric acoustic stimulation
    • Adunka O., Kiefer J., Unkelbach MH, Lehnert T., Gstoettner W. Development and evaluation of an improved cochlear implant electrode design for electric acoustic stimulation. Laryngoscope 2004; 114:1237-1241.
    • (2004) Laryngoscope , vol.114 , pp. 1237-1241
    • Adunka, O.1    Kiefer, J.2    Unkelbach, M.H.3    Lehnert, T.4    Gstoettner, W.5
  • 3
    • 18644385795 scopus 로고    scopus 로고
    • Combined electric and acoustic stimulation of the auditory system: Results of a clinical study
    • Kiefer J., Pok M., Adunka O., et al. Combined electric and acoustic stimulation of the auditory system: results of a clinical study. Audiol Neurootol 2005; 10:134-144.
    • (2005) Audiol Neurootol , vol.10 , pp. 134-144
    • Kiefer, J.1    Pok, M.2    Adunka, O.3
  • 4
    • 34248166003 scopus 로고    scopus 로고
    • Application of a corticosteroid (Triamcinolon) protects inner ear function after surgical intervention
    • Ye Q., Tillein J., Hartmann R., Gstoettner W., Kiefer J. Application of a corticosteroid (Triamcinolon) protects inner ear function after surgical intervention. Ear Hear 2007; 28:361-369.
    • (2007) Ear Hear , vol.28 , pp. 361-369
    • Ye, Q.1    Tillein, J.2    Hartmann, R.3    Gstoettner, W.4    Kiefer, J.5
  • 5
    • 36549014716 scopus 로고    scopus 로고
    • Intratympanic versus intravenous delivery of methylprednisolone to cochlear perilymph
    • Bird PA, Begg EJ, Zhang M., Keast AT, Murray DP, Balkany TJ. Intratympanic versus intravenous delivery of methylprednisolone to cochlear perilymph. Otol Neurotol 2007; 28:1124-1130.
    • (2007) Otol Neurotol , vol.28 , pp. 1124-1130
    • Bird, P.A.1    Begg, E.J.2    Zhang, M.3    Keast, A.T.4    Murray, D.P.5    Balkany, T.J.6
  • 6
    • 41349085428 scopus 로고    scopus 로고
    • Dexamethasone concentration gradients along scala tympani after application to the round window membrane
    • Plontke SK, Biegner T., Kammerer B., Delabar U., Salt AN. Dexamethasone concentration gradients along scala tympani after application to the round window membrane. Otol Neurotol 2008; 29:401-406.
    • (2008) Otol Neurotol , vol.29 , pp. 401-406
    • Plontke, S.K.1    Biegner, T.2    Kammerer, B.3    Delabar, U.4    Salt, A.N.5
  • 7
    • 33744471135 scopus 로고    scopus 로고
    • Demonstration of a longitudinal concentration gradient along scala tympani by sequential sampling of perilymph from the cochlear apex
    • Mynatt R., Hale SA, Gill RM, Plontke SK, Salt AN. Demonstration of a longitudinal concentration gradient along scala tympani by sequential sampling of perilymph from the cochlear apex. J Assoc Res Otolaryngol 2006; 7: 182-193.
    • (2006) J Assoc Res Otolaryngol , vol.7 , pp. 182-193
    • Mynatt, R.1    Hale, S.A.2    Gill, R.M.3    Plontke, S.K.4    Salt, A.N.5
  • 8
    • 0002291192 scopus 로고
    • The microscopic evaluation of hard tissue implants
    • Williams DF, ed, Boca Raton, FL: CRC Press;
    • Plenk H. The microscopic evaluation of hard tissue implants. In: Williams DF, ed. Techniques of Biocompatibility Testing, Vol. 1. Boca Raton, FL: CRC Press; 1986: 35-81.
    • (1986) Techniques of Biocompatibility Testing , vol.1 , pp. 35-81
    • Plenk, H.1
  • 9
    • 23344447785 scopus 로고    scopus 로고
    • A model for cochlear implant electrode insertion and force evaluation: Results with a new electrode design and insertion technique
    • Roland TJ. A model for cochlear implant electrode insertion and force evaluation: Results with a new electrode design and insertion technique. Laryngoscope 2005; 115:1325-1339.
    • (2005) Laryngoscope , vol.115 , pp. 1325-1339
    • Roland, T.J.1
  • 10
    • 33747879532 scopus 로고    scopus 로고
    • Impact of electrode insertion depth on intracochlear trauma
    • Adunka O., Kiefer J. Impact of electrode insertion depth on intracochlear trauma. Otolaryngol Head Neck Surg 2006; 135:374-382.
    • (2006) Otolaryngol Head Neck Surg , vol.135 , pp. 374-382
    • Adunka, O.1    Kiefer, J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.