Volumn 38, Issue 3, 2009, Pages 285-305

Experimental performance evaluation of an equipment isolation using MR dampers

Author keywords

Decentralized control; Equipment isolation; MR damper; Sliding mode control

Indexed keywords

AD HOC NETWORKS; COMPUTER SYSTEM RECOVERY; CONTROL SYSTEM ANALYSIS; DAMPING; EARTHQUAKES; EQUIPMENT; FLOORS; SLIDING MODE CONTROL;

EID: 66149155084     PISSN: 00988847     EISSN: 10969845     Source Type: Journal    
DOI: 10.1002/eqe.844     Document Type: Article
Times cited : (46)

References (17)
  • 2
    • 59349091616 scopus 로고    scopus 로고
    • Base isolation technologies for seismic protection of museum artifacts
    • San Francisco, CA, 21-24 September
    • Mysilimaj B, Gamble S, Chin-Quee D, Davies A. Base isolation technologies for seismic protection of museum artifacts. The 2003 IMAFA Annual Conference, San Francisco, CA, 21-24 September 2003.
    • (2003) The 2003 IMAFA Annual Conference
    • Mysilimaj, B.1    Gamble, S.2    Chin-Quee, D.3    Davies, A.4
  • 8
    • 33646365874 scopus 로고    scopus 로고
    • Application of Some semi-active-control algorithms to a smart base-isolated building employing MR dampers
    • Jung HJ, Choi KM, Spencer BF, Lee IW. Application of Some semi-active-control algorithms to a smart base-isolated building employing MR dampers. Structural Control and Health Monitoring 2006; 13:693-704.
    • (2006) Structural Control and Health Monitoring , vol.13 , pp. 693-704
    • Jung, H.J.1    Choi, K.M.2    Spencer, B.F.3    Lee, I.W.4
  • 9
    • 0034255331 scopus 로고    scopus 로고
    • Semiactive control strategies for MR dampers: Comparative study
    • Jansen LM, Dyke SJ. Semiactive control strategies for MR dampers: comparative study. Journal of Engineering Mechanics (ASCE) 2000; 126(8):795-803.
    • (2000) Journal of Engineering Mechanics (ASCE) , vol.126 , Issue.8 , pp. 795-803
    • Jansen, L.M.1    Dyke, S.J.2
  • 10
    • 34447544003 scopus 로고    scopus 로고
    • Performance and reliability of semi-active equipment isolation
    • Gavin HP, Zaicenco A. Performance and reliability of semi-active equipment isolation. Journal of Sound and Vibration 2007; 306:74-90.
    • (2007) Journal of Sound and Vibration , vol.306 , pp. 74-90
    • Gavin, H.P.1    Zaicenco, A.2
  • 11
    • 16244415166 scopus 로고    scopus 로고
    • Displacement control of isolated structures with semi-active control devices
    • Loh CH, Wu LY, Lin PY. Displacement control of isolated structures with semi-active control devices. Journal of Structural Control 2003; 10:77-100.
    • (2003) Journal of Structural Control , vol.10 , pp. 77-100
    • Loh, C.H.1    Wu, L.Y.2    Lin, P.Y.3
  • 13
    • 0003811636 scopus 로고
    • Sliding mode control of seismic-excited linear and nonlinear civil engineering structures
    • Technical Report NCREE-94-0017, National Center for Earthquake Engineering Research, Buffalo, NY
    • Yang JN, Wu JC, Agrawal AK, Li Z. Sliding mode control of seismic-excited linear and nonlinear civil engineering structures. Technical Report NCREE-94-0017, National Center for Earthquake Engineering Research, Buffalo, NY, 1994.
    • (1994)
    • Yang, J.N.1    Wu, J.C.2    Agrawal, A.K.3    Li, Z.4