메뉴 건너뛰기




Volumn 23, Issue 6, 2008, Pages 1029-1036

A comparison of fabrication precision and mechanical reliability of 2 zirconia implant abutments

Author keywords

Fractography; Fracture strength; Key interface features; Metrology inspection; Weibull modulus

Indexed keywords

BIOMEDICAL AND DENTAL MATERIALS; ZIRCONIUM; ZIRCONIUM OXIDE;

EID: 66149129216     PISSN: 08822786     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (45)

References (14)
  • 1
    • 0035453135 scopus 로고    scopus 로고
    • Alumina ceramic implant abutments used for single-tooth replacements prospective 1-to 3-year multicenter study
    • Andersson B, Taylor A, Lang BR, et al. Alumina ceramic implant abutments used for single-tooth replacements prospective 1 - to 3-year multicenter study. Int J Prosthodont 2001 ;14: 432-438.
    • (2001) Int J Prosthodont , vol.14 , pp. 432-438
    • Andersson, B.1    Taylor, A.2    Lang, B.R.3    Al, E.4
  • 2
    • 0033154854 scopus 로고    scopus 로고
    • Ceramic abutments used for short-span fixed partial dentures: A prospective 2-year multicenter study
    • Andersson B, Scharer P, Simion M, Bergstrom C. Ceramic abutments used for short-span fixed partial dentures: A prospective 2-year multicenter study. Int J Prosthodont 1999;12: 318-324.
    • (1999) Int J Prosthodont , vol.12 , pp. 318-324
    • Andersson, B.1    Scharer, P.2    Simion, M.3    Bergstrom, C.4
  • 3
    • 0033205480 scopus 로고    scopus 로고
    • Glass-infiltrated zirconia alumina- based ceramic for crowns and fixed partial dentures
    • McLaren EA, White SN. Glass-infiltrated zirconia alumina- based ceramic for crowns and fixed partial dentures. Pract Periodontics Aesthet Dent 1999;11:985-994.
    • (1999) Pract Periodontics Aesthet Dent , vol.11 , pp. 985-994
    • McLaren, E.A.1    White, S.N.2
  • 4
    • 0030433188 scopus 로고    scopus 로고
    • Yemm R.Twitch interpolation in the assessment of the maximum force-generating capacity of the jaw-closing muscles in man
    • Lyons MF, Cadden SW, Baxendale RH, Yemm R.Twitch interpolation in the assessment of the maximum force-generating capacity of the jaw-closing muscles in man. Arch Oral Biol 1996;41:1161-1168.
    • (1996) Arch Oral Biol , vol.41 , pp. 1161-1168
    • Lyons, M.F.1    Cadden, S.W.2    Baxendale, R.H.3
  • 5
    • 0035983861 scopus 로고    scopus 로고
    • Morneburg T.Task-dependence of activity/bite- force relations and its impact on estimation of chewing force from EMG
    • Proeschel PA, Morneburg T.Task-dependence of activity/bite- force relations and its impact on estimation of chewing force from EMG.J Dent Res 2002;81:464-468.
    • (2002) J Dent Res , vol.81 , pp. 464-468
    • Proeschel, P.A.1
  • 6
    • 0141923180 scopus 로고    scopus 로고
    • In vivo fracture resistance of implant-supported all-ceramic restorations
    • Yildirim M, Fischer H, Marx R, Edelhoff D. In vivo fracture resistance of implant-supported all-ceramic restorations. J Prosthet Dent 2003;90:325-331.
    • (2003) J Prosthet Dent , vol.90 , pp. 325-331
    • Yildirim, M.1    Fischer, H.2    Marx, R.3    Edelhoff, D.4
  • 7
    • 32244447142 scopus 로고    scopus 로고
    • Fracture resistance of single-tooth implant-supported all-ceramic restorations: An in vitro study
    • Feb
    • Att W, Kurun S,Gerds T, Strub JR. Fracture resistance of single-tooth implant-supported all-ceramic restorations: An in vitro study.J Prosthet Dent 2006 Feb;95(2):111-116.
    • (2006) J Prosthet Dent , vol.95 , Issue.2 , pp. 111-116
    • Att, W.1    Kurun Sgerds, T.2    Strub, J.R.3
  • 8
    • 33748373989 scopus 로고    scopus 로고
    • Strub JR.Zirconia-implant-supported all-ceramic crowns withstand long-term load: A pilot investigation
    • Oct
    • Kohal RJ, Klaus G, Strub JR.Zirconia-implant-supported all-ceramic crowns withstand long-term load: A pilot investigation. Clin Oral Implants Res 2006 Oct;17(5):565-571.
    • (2006) Clin Oral Implants Res , vol.17 , Issue.5 , pp. 565-571
    • Kohal, R.J.1    Klaus, G.2
  • 9
    • 0027346459 scopus 로고
    • Esthetic high-strength implant abutments. Part i
    • Prestipino V, Ingber A. Esthetic high-strength implant abutments. Part I.J Esthet Dent 1993;5:29-36.
    • (1993) J Esthet Dent , vol.5 , pp. 29-36
    • Prestipino, V.1    Ingber, A.2
  • 10
    • 0027566311 scopus 로고
    • Esthetic high-strength implant abutments. Part II
    • Prestipino V, Ingber A. Esthetic high-strength implant abutments. Part II. J Esthet Dent 1993;5:63-68.
    • (1993) J Esthet Dent , vol.5 , pp. 63-68
    • Prestipino, V.1    Ingber, A.2
  • 11
    • 2542639442 scopus 로고    scopus 로고
    • Experimental zirconia abutments for implant-supported single-tooth restorations in esthetically demanding regions: 4-year results of a prospective clinical study
    • Glauser R, Sailer I, Wohlwend A, Studer S, Schibli M, Schärer P. Experimental zirconia abutments for implant-supported single-tooth restorations in esthetically demanding regions: 4-year results of a prospective clinical study. Int J Prosthodont 2004;17:285-290.
    • (2004) Int J Prosthodont , vol.17 , pp. 285-290
    • Glauser, R.1    Sailer, I.2    Wohlwend, A.3    Studer, S.4    Schibli, M.5    Schärer, P.6
  • 12
    • 0034308991 scopus 로고    scopus 로고
    • Utilizing computer generated titanium permanent healing abutments to promote ideal gingival form and anatomic restorations on implants
    • Kerstein RB, Castellucci F, Osorio J. Utilizing computer generated titanium permanent healing abutments to promote ideal gingival form and anatomic restorations on implants. Compend Contin Educ Dent 2000;21:793-802.
    • (2000) Compend Contin Educ Dent , vol.21 , pp. 793-802
    • Kerstein, R.B.1    Castellucci, F.2    Osorio, J.3
  • 13
    • 70350136815 scopus 로고    scopus 로고
    • Class II Special Controls Guidance Document: Root-form Endosseous Dental Implants and Endosseous Dental Abutments
    • U.S. Food and Drug Administration, Section 8 Mechanical Properties, May 14
    • Class II Special Controls Guidance Document: Root-form Endosseous Dental Implants and Endosseous Dental Abutments. U.S. Food and Drug Administration, Section 8 Mechanical Properties, May 14,2002. [AU: Place of publication?]
    • (2002) AU: Place of Publication?


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.