메뉴 건너뛰기




Volumn 29, Issue 4, 2009, Pages 451-455

25-gauge sutureless vitrectomy: Variations in incision architecture

Author keywords

25 gauge vitrectomy; Endophthalmitis; Oblique; Sutureless; Wound architecture

Indexed keywords

ARTICLE; CADAVER; CANNULA; CONJUNCTIVA; EYE SURGERY; HISTOLOGY; HUMAN; HUMAN TISSUE; INCISION; POSTOPERATIVE PERIOD; SCLERA; SCLERA DISEASE; SURGICAL EQUIPMENT; SURGICAL TECHNIQUE; SUTURELESS VITRECTOMY; TISSUE SECTION; TROCAR; VITRECTOMY; WOUND; WOUND HEALING; CATHETERIZATION; EQUIPMENT DESIGN; INSTRUMENTATION; INTRAOPERATIVE PERIOD; METHODOLOGY; PATHOLOGY; PILOT STUDY; SURGICAL INSTRUMENT; VITREOUS BODY;

EID: 66149113734     PISSN: 0275004X     EISSN: None     Source Type: Journal    
DOI: 10.1097/IAE.0b013e31819c6347     Document Type: Article
Times cited : (21)

References (10)
  • 1
    • 36549012230 scopus 로고    scopus 로고
    • Wills Eye Retina Service. Incidence of endophthalmitis after 20- and 25-gauge vitrectomy
    • Kunimoto DY, Kaiser RS; Wills Eye Retina Service. Incidence of endophthalmitis after 20- and 25-gauge vitrectomy. Ophthalmology 2007;114:2133-2137.
    • (2007) Ophthalmology , vol.114 , pp. 2133-2137
    • Kunimoto, D.Y.1    Kaiser, R.S.2
  • 2
    • 34548706049 scopus 로고    scopus 로고
    • Sutureless microincision vitrectomy surgery: Unclear benefit, uncertain safety
    • Lewis H. Sutureless microincision vitrectomy surgery: unclear benefit, uncertain safety. Am J Ophthalmol 2007;144:613- 615.
    • (2007) Am J Ophthalmol , vol.144 , pp. 613-615
    • Lewis, H.1
  • 3
    • 0028222976 scopus 로고
    • Surgical wound defects associated with endophthalmitis
    • Maxwell DP, Diamond JG, May DR. Surgical wound defects associated with endophthalmitis. Ophthalmic Surg 1994;25: 157-161.
    • (1994) Ophthalmic Surg , vol.25 , pp. 157-161
    • Maxwell, D.P.1    Diamond, J.G.2    May, D.R.3
  • 4
    • 33744810622 scopus 로고    scopus 로고
    • Oblique sclerotomy technique for prevention of incompetent wound closure in transconjunctival 25-gauge vitrectomy
    • Lopez-Guajardo L, Pareja-Esteban J, Teus-Guezala MA. Oblique sclerotomy technique for prevention of incompetent wound closure in transconjunctival 25-gauge vitrectomy. Am J Ophthalmol 2006;141:1154-1156.
    • (2006) Am J Ophthalmol , vol.141 , pp. 1154-1156
    • Lopez-Guajardo, L.1    Pareja-Esteban, J.2    Teus-Guezala, M.A.3
  • 6
    • 42549129421 scopus 로고    scopus 로고
    • Ocular surface fluid contamination of sutureless 25-gauge vitrectomy incisions
    • Singh A, Chen JA, Stewart JM. Ocular surface fluid contamination of sutureless 25-gauge vitrectomy incisions. Retina 2008;28:553-557.
    • (2008) Retina , vol.28 , pp. 553-557
    • Singh, A.1    Chen, J.A.2    Stewart, J.M.3
  • 8
    • 0344442787 scopus 로고    scopus 로고
    • Dynamic morphology of clear corneal cataract incisions
    • McDonnell PJ, Taban M, Sarayba M, et al. Dynamic morphology of clear corneal cataract incisions. Ophthalmology 2003; 110:2342-2348.
    • (2003) Ophthalmology , vol.110 , pp. 2342-2348
    • McDonnell, P.J.1    Taban, M.2    Sarayba, M.3
  • 9
    • 1542393492 scopus 로고    scopus 로고
    • Dynamic morphology of sutureless cataract wounds - effect of incision angle and location
    • Taban M, Rao B, Reznik J, Zhang J, Chen Z, McDonnell PJ. Dynamic morphology of sutureless cataract wounds - effect of incision angle and location. Surv Ophthalmol 2004;49:S62- S72.
    • (2004) Surv Ophthalmol , vol.49
    • Taban, M.1    Rao, B.2    Reznik, J.3    Zhang, J.4    Chen, Z.5    McDonnell, P.J.6
  • 10
    • 0014597151 scopus 로고
    • Direct-recorded intraocular pressure variations in a human subject
    • Coleman DJ, Trokel S. Direct-recorded intraocular pressure variations in a human subject. Arch Ophthalmol 1962;82:637-640.
    • (1962) Arch Ophthalmol , vol.82 , pp. 637-640
    • Coleman, D.J.1    Trokel, S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.