메뉴 건너뛰기




Volumn , Issue , 2008, Pages 272-275

Characteristics evaluation of the partial arc discharge and the silicone rubber surface by dynamic drop test

Author keywords

[No Author keywords available]

Indexed keywords

AC VOLTAGE; BEFORE AND AFTER; DROP TEST; ELECTROLYTE SOLUTIONS; PARTIAL ARC DISCHARGE; SILICONE RUBBER;

EID: 65949124458     PISSN: 00849162     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/CEIDP.2008.4772897     Document Type: Conference Paper
Times cited : (13)

References (4)
  • 1
    • 65949088857 scopus 로고    scopus 로고
    • Barsch et al. : CIGRE WG D1 -14 (2004/04)
    • Barsch et al. : CIGRE WG D1 -14 (2004/04)
  • 3
    • 33646387736 scopus 로고    scopus 로고
    • Electrohydrodynamic behaviour of water droplet on an electrically stressed hydrophobic surface
    • Y. Zhu et al. "Electrohydrodynamic behaviour of water droplet on an electrically stressed hydrophobic surface", Journal of physics D: Applied physics, 39. pp. 1970-1975, 2006
    • (2006) Journal of Physics D: Applied Physics , vol.39 , pp. 1970-1975
    • Zhu, Y.1
  • 4
    • 65949090992 scopus 로고    scopus 로고
    • Studies on erosion of silicone rubber exposed to partial arc discharges
    • Elsevier
    • K. Haji, et al. "Studies on erosion of silicone rubber exposed to partial arc discharges", Polymer Degradation and Stability, Elsevier, pp. 1-8, 2008
    • (2008) Polymer Degradation and Stability , pp. 1-8
    • Haji, K.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.