메뉴 건너뛰기




Volumn , Issue , 2009, Pages 240-243

On-chip blood viscometer towards point-of-care hematological diagnosis

Author keywords

[No Author keywords available]

Indexed keywords

BLOOD FLOW; BLOOD VISCOSITY; COMPLEX CONFIGURATION; COUETTE RHEOMETERS; ELECTRICAL IMPEDANCE; HEMATOLOGICAL PARAMETERS; MICRO DEVICES; ON CHIPS; POINT OF CARE; RAPID RESPONSE; ROTATIONAL SHAFTS; ROTATIONAL VISCOMETER; SAMPLE CONSUMPTION; SAMPLE VOLUME; SHEAR RATES; START POINT;

EID: 65949118521     PISSN: 10846999     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/MEMSYS.2009.4805363     Document Type: Conference Paper
Times cited : (10)

References (14)
  • 1
    • 65949114598 scopus 로고    scopus 로고
    • "Understanding disuse atrophy,"
    • W. Lowe, "Understanding Disuse Atrophy," Massage Today, vol. 5, 2005.
    • (2005) Massage Today , vol.5
    • Lowe, W.1
  • 2
    • 0014341349 scopus 로고
    • "Blood viscosity and thrombosis in vitro in patients with previous myocardial infarction,"
    • M. C. Rozenberg, "Blood viscosity and thrombosis in vitro in patients with previous myocardial infarction," Angiology, vol. 19, pp. 527-533, 1968.
    • (1968) Angiology , vol.19 , pp. 527-533
    • Rozenberg, M.C.1
  • 3
    • 0016357290 scopus 로고
    • "Blood viscosity and open heart surgery. A comparison of values in systemic and pulmonary blood vessels,"
    • H. B. Aronson, S. Cotev, F. Magora, J. B. Borman, and G. Merin, "Blood viscosity and open heart surgery. A comparison of values in systemic and pulmonary blood vessels," Br J Anaesth, vol. 46, pp. 722-725, 1974.
    • (1974) Br J Anaesth , vol.46 , pp. 722-725
    • Aronson, H.B.1    Cotev, S.2    Magora, F.3    Borman, J.B.4    Merin, G.5
  • 4
    • 0014958503 scopus 로고
    • "Shear dependence of effective cell volume as a determinant of blood viscosity,"
    • S. Chien, "Shear dependence of effective cell volume as a determinant of blood viscosity," Science, vol. 168, pp. 977-979, 1970.
    • (1970) Science , vol.168 , pp. 977-979
    • Chien, S.1
  • 5
    • 0011839823 scopus 로고
    • "Influence of flow properties of blood upon viscosity-hematocrit relationships,"
    • R. E. Wells, Jr. and E. W. Merrill, "Influence of flow properties of blood upon viscosity-hematocrit relationships," J Clin Invest, vol. 41, pp. 1591-1598, 1962.
    • (1962) J Clin Invest , vol.41 , pp. 1591-1598
    • Wells Jr., R.E.1    Merrill, E.W.2
  • 6
    • 13644275447 scopus 로고    scopus 로고
    • "Measurement of red cell deformability and whole blood viscosity using laser-diffraction slit rheometer,"
    • S. Shin, Y. Ku, M. S. Park, and J. S. Suh, "Measurement of red cell deformability and whole blood viscosity using laser-diffraction slit rheometer," Korea-Australia Rheology Journal, vol. 16, pp. 85-90, 2004.
    • (2004) Korea-Australia Rheology Journal , vol.16 , pp. 85-90
    • Shin, S.1    Ku, Y.2    Park, M.S.3    Suh, J.S.4
  • 7
    • 0000617320 scopus 로고
    • "Viscosity of normal human blood under normothermic and hypothermic conditions,"
    • P. W. Rand, E. Lacombe, H. E. Hunt, and W. H. Austin, "Viscosity of normal human blood under normothermic and hypothermic conditions," J Appl Physiol, vol. 19, pp. 117-122, 1964.
    • (1964) J Appl Physiol , vol.19 , pp. 117-122
    • Rand, P.W.1    Lacombe, E.2    Hunt, H.E.3    Austin, W.H.4
  • 8
    • 0027284524 scopus 로고
    • Triple-frequency method for measuring blood impedance
    • T. Zhao, B. Jacobson, and T. Ribbe, "Triple-frequency method for measuring blood impedance". Physiol Meas, vol. 14(2), pp. 145-156, 1993. (Pubitemid 23208651)
    • (1993) Physiological Measurement , vol.14 , Issue.2 , pp. 145-156
    • Zhao, T.1    Jacobson, B.2    Ribbe, T.3
  • 9
    • 0024424759 scopus 로고
    • Electric properties of flowing blood and impedance cardiography
    • K.R. Visser, "Electric properties of flowing blood and impedance cardiography". Annals of Biomedical Engineering, vol. 17(5), pp. 463-473, 1989. (Pubitemid 19253982)
    • (1989) Annals of Biomedical Engineering , vol.17 , Issue.5 , pp. 463-473
    • Visser, K.R.1
  • 10
    • 0016483641 scopus 로고
    • "The effect of haematocrit on the resistivity of human blood at37°C and lOOkHz"
    • D.W. Hill, and F.D. Thompson, "The effect of haematocrit on the resistivity of human blood at37°C and lOOkHz". Med Biol Eng, vol. 13(2), pp. 182-185, 1975.
    • (1975) Med Biol Eng , vol.13 , Issue.2 , pp. 182-185
    • Hill, D.W.1    Thompson, F.D.2
  • 11
    • 0025891043 scopus 로고
    • "The electrical impedance of plasma: A laboratory simulation of the effect of changes in chemistry"
    • H.D. Fuller, "The electrical impedance of plasma: A laboratory simulation of the effect of changes in chemistry". Ann Biom Eng, vol. 19(2), pp. 123-129, 1991.
    • (1991) Ann Biom Eng , vol.19 , Issue.2 , pp. 123-129
    • Fuller, H.D.1
  • 13
    • 0014254029 scopus 로고
    • "Electrode polarization impedance and measurements in biological materials"
    • H.P. Schwan, "Electrode polarization impedance and measurements in biological materials". Ann. New York Acad. Science, vol. 148, pp. 191-209, 1968.
    • (1968) Ann. New York Acad. Science , vol.148 , pp. 191-209
    • Schwan, H.P.1
  • 14
    • 0034814808 scopus 로고    scopus 로고
    • Hemocompatibility, biocompatibility, inflammatory and in vivo studies of primary reference materials low-density polyethylene and polydimethylsiloxane: A review
    • DOI 10.1002/jbm.1043
    • M.C. Belanger, and Y. Marois, "Hemocompatibility, biocompatibility, inflammatory and in vivo studies of primary reference material low-density polyethylene and polydimenthylsiloxane: A review". Journal of Biomedical Materials Research Part B: Applied Biomaterials, vol. 58(5), pp. 467-477, 2001. (Pubitemid 32899901)
    • (2001) Journal of Biomedical Materials Research , vol.58 , Issue.5 , pp. 467-477
    • Belanger, M.-C.1    Marois, Y.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.