메뉴 건너뛰기




Volumn , Issue , 2009, Pages 1932-1938

Improved crowbar control strategy of DFIG based wind turbines for grid fault ride-Through

Author keywords

Crowbar; DFIG; Hysteresis control; Low Voltage Ride through; Voltage dip

Indexed keywords

CROWBAR; DFIG; HYSTERESIS CONTROL; LOW VOLTAGE RIDE-THROUGH; VOLTAGE DIP;

EID: 65949116626     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/APEC.2009.4802937     Document Type: Conference Paper
Times cited : (86)

References (12)
  • 2
    • 0030146394 scopus 로고    scopus 로고
    • Doubly fed induction generator using back-to-back PWM converters and its application to variablespeed wind-energy generation
    • R. Pena, J. C. Clare, G. M. Asher, "Doubly fed induction generator using back-to-back PWM converters and its application to variable speed wind-energy generation", IEE Proceedings Electrical Power Application 1996; 143(3): 231-241. (Pubitemid 126760209)
    • (1996) IEE Proceedings: Electric Power Applications , vol.143 , Issue.3 , pp. 231-241
    • Pena, R.1    Clare, J.C.2    Asher, G.M.3
  • 3
    • 28644452249 scopus 로고    scopus 로고
    • "Modeling and simulation of doubly fed induction generators for variable speed wind turbines integrated in a distribution network"
    • CD-ROM
    • S. El Aimani, B. Francois, B. Robyns, F. Minne, "Modeling and simulation of doubly fed induction generators for variable speed wind turbines integrated in a distribution network", Proceedings of EPE 2003, Toulouse, September 2003, CD-ROM.
    • (2003) Proceedings of EPE 2003
    • Aimani S.El1    Francois, B.2    Robyns, B.3    Minne, F.4
  • 4
    • 0003274644 scopus 로고    scopus 로고
    • IEEE Recommended Practices and Requirements for Harmonic Control in Electrical Power System
    • IEEE Recommended Practices and Requirements for Harmonic Control in Electrical Power System, IEEE Standard 519-1992.
    • IEEE Standard , pp. 519-1992
  • 5
    • 67649422559 scopus 로고    scopus 로고
    • "Modeling and Control of Doubly Fed Induction Generator Wind Turbines by Using Causal Ordering Graph during Voltage Dips"
    • Ling Peng, Yongdong Li, Bruno Francois, "Modeling and Control of Doubly Fed Induction Generator Wind Turbines by Using Causal Ordering Graph during Voltage Dips", ICEMS 2008, China, CD-ROM.
    • ICEMS 2008
    • Ling Peng1    Yongdong Li2    Bruno Francois3
  • 6
    • 78649967993 scopus 로고    scopus 로고
    • "Simulation of Doubly Fed Induction Generator wind turbine with an active crowbar"
    • Lavita, CD-ROM
    • J.K. Niiranen, "Simulation of Doubly Fed Induction Generator wind turbine with an active crowbar", EPE-PEMC 2004, Latvia, CD-ROM.
    • EPE-PEMC2004
    • Niiranen, J.K.1
  • 7
    • 20544451598 scopus 로고    scopus 로고
    • "Ridethrough of wind turbines with doubly-fed induction generator during a voltage dip"
    • June
    • J. Morren, S. W. H. de Haan, "Ridethrough of wind turbines with doubly-fed induction generator during a voltage dip". IEEE Trans. Energy Conversion, vol.20, no. 2, pp. 435-441, Jun. 2005.
    • (2005) IEEE Trans. Energy Conversion , vol.20 , Issue.2 , pp. 435-441
    • Morren, J.1    De Haan, S.W.H.2
  • 10
    • 65949123724 scopus 로고
    • "A new approach for synthesizing logic connection controllers in power converters"
    • September, Sevilla, CD-ROM
    • B. Francois, J.P. Cambronne, J.P. Hautier, "A new approach for synthesizing logic connection controllers in power converters", EPE'95, September 1995, Sevilla, CD-ROM.
    • (1995) EPE'95
    • Francois, B.1    Cambronne, J.P.2    Hautier, J.P.3
  • 11
    • 51049115503 scopus 로고    scopus 로고
    • "Analysis of three phase grid failure on doubly fed induction generator ride-through using Crowbars"
    • Aalborg, Denmark, September
    • R. Lohde, S. Jensen, A. Knop, F.W. Fuchs, "Analysis of three phase grid failure on doubly fed induction generator ride-through using Crowbars", Proceedings of EPE 2007, Aalborg, Denmark, September, 2007.
    • (2007) Proceedings of EPE 2007
    • Lohde, R.1    Jensen, S.2    Knop, A.3    Fuchs, F.W.4
  • 12
    • 33947430524 scopus 로고    scopus 로고
    • Control of a doubly fed induction generator in a wind turbine during grid fault ride-through
    • DOI 10.1109/TEC.2006.875783
    • Dawei Xiang, Li Ran, Tavner, P.J. and Yang, S., "Control of a doubly fed induction generator in a wind turbine during grid fault ride-through," IEEE Trans. Energy Convers., vol.21, no. 3, pp. 652-662, Sep. 2006. (Pubitemid 46445154)
    • (2006) IEEE Transactions on Energy Conversion , vol.21 , Issue.3 , pp. 652-662
    • Xiang, D.1    Ran, L.2    Tavner, P.J.3    Yang, S.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.