메뉴 건너뛰기




Volumn 89, Issue 2, 2009, Pages 456-465

Development of novel thermal sprayed antibacterial coating and evaluation of release properties of silver ions

Author keywords

Antibacterial; Calcium phosphate coating; HA forming ability; Silver ions release; Thermal spraying

Indexed keywords

AMORPHOUS STRUCTURES; ANTI-BACTERIAL ACTIVITY; ANTIBACTERIAL; ANTIBACTERIAL COATINGS; BONE BONDING; COATING TECHNOLOGIES; ELEMENTARY ANALYSIS; FETAL BOVINE SERUM; FORMING ABILITY; HA-FORMING ABILITY; IMPLANT SURFACE; IMPLANT-ASSOCIATED INFECTION; IN-VITRO; METHICILLIN-RESISTANT STAPHYLOCOCCUS AUREUS; PARTS PER BILLION; PHYSICAL AND CHEMICAL PROPERTIES; RELEASE PROPERTY; SILVER IONS; SILVER IONS RELEASE; SIMULATED BODY FLUIDS; TIME COURSE;

EID: 65949107050     PISSN: 15524973     EISSN: 15524981     Source Type: Journal    
DOI: 10.1002/jbm.b.31235     Document Type: Article
Times cited : (127)

References (53)
  • 3
    • 0242592006 scopus 로고    scopus 로고
    • Gentamicin coating of metallic implants reduces implant-related osteomyelitis in rats
    • DOI 10.1016/S8756-3282(03)00050-4
    • Lucke M, Schmidmaier G, Sadoni S, Wildemann B, Schiller R, Haas NP, Raschke M. Gentamicin coating of metallic implants reduces implant-related osteomyelitis in rats. Bone 2003;32:521-531. (Pubitemid 39665711)
    • (2003) Bone , vol.32 , Issue.5 , pp. 521-531
    • Lucke, M.1    Schmidmaier, G.2    Sadoni, S.3    Wildemann, B.4    Schiller, R.5    Haas, N.P.6    Raschke, M.7
  • 4
    • 33646876196 scopus 로고    scopus 로고
    • The effects of combined gentamicin-hydroxyapatite coating for cementless joint prostheses on the reduction of infection rates in a rabbit infection prophylaxis model
    • DOI 10.1016/j.biomaterials.2006.04.035, PII S0142961206003887
    • Alt V, Bitschnau A, Osterling J, Sewing A, Meyer C, Kraus R, Meissner SA, Wenish A, Domann E, Schnettler R. The effects of combined gentamicin- hydroxyapatite coating for cementless joint prostheses on the reduction of infection rates in a rabbit infection prophylaxis model. Biomaterials 2006;27:4627-4634. (Pubitemid 43783227)
    • (2006) Biomaterials , vol.27 , Issue.26 , pp. 4627-4634
    • Alt, V.1    Bitschnau, A.2    Osterling, J.3    Sewing, A.4    Meyer, C.5    Kraus, R.6    Meissner, S.A.7    Wenisch, S.8    Domann, E.9    Schnettler, R.10
  • 6
    • 0033809133 scopus 로고    scopus 로고
    • Prevention of pin track infection in external fixation with Silver coated pins: Clinical and microbiological results
    • Masse A, Bruno A, Bosetti M, Biasibetti A, Cannas M, Gallinaro P. Prevention of pin track infection in external fixation with Silver coated pins: Clinical and microbiological results. J Biomed Mater Res 2000;53:600-604.
    • (2000) J Biomed Mater Res , vol.53 , pp. 600-604
    • Masse, A.1    Bruno, A.2    Bosetti, M.3    Biasibetti, A.4    Cannas, M.5    Gallinaro, P.6
  • 7
    • 0036132139 scopus 로고    scopus 로고
    • Silver coated materials for external fixation devices: In vitro biocompatibility and genotoxicity
    • Bosetti M, Masse A, Tobin E, Cannas M. Silver coated materials for external fixation devices: In vitro biocompatibility and genotoxicity. Biomaterials 2002;23:887-892.
    • (2002) Biomaterials , vol.23 , pp. 887-892
    • Bosetti, M.1    Masse, A.2    Tobin, E.3    Cannas, M.4
  • 10
    • 33746840674 scopus 로고    scopus 로고
    • In vitro anti-bacterial and biological properties of magnetron co-sputtered silver-containing hydroxyapatite coating
    • Chen W, Liu Y, Courtney HS, Bettenga M, Agrawal CM, Bumgrardner JD, Ong JL. In vitro anti-bacterial and biological properties of magnetron co-sputtered silver-containing hydroxyapatite coating. Biomaterials 2006;27:5512-5517.
    • (2006) Biomaterials , vol.27 , pp. 5512-5517
    • Chen, W.1    Liu, Y.2    Courtney, H.S.3    Bettenga, M.4    Agrawal, C.M.5    Bumgrardner, J.D.6    Ong, J.L.7
  • 11
    • 65949111669 scopus 로고    scopus 로고
    • Controlled release of silver ions from an electrochemically deposited hydroxyapatite coating
    • Presented at the Paper No: 0330.
    • Ghani Y, Coathup MJ, Unnithan A, Hing K, Blumn GW. Controlled release of silver ions from an electrochemically deposited hydroxyapatite coating. Presented at the 53rd Annual Meeting of the Orthopaedic Research Society 2007. Paper No: 0330. Orthopaedic Research Society (ORS); http://www.ors.org/web/ index.asp.
    • 53rd Annual Meeting of the Orthopaedic Research Society 2007
    • Ghani, Y.1    Coathup, M.J.2    Unnithan, A.3    Hing, K.4    Blumn, G.W.5
  • 13
    • 1642633627 scopus 로고    scopus 로고
    • First clinical experience with a mechanical valve with silver coating
    • disccusion 129-130.
    • Brutel de la Riviere A, Dossche KM, Birnbaum DE, Hacker R. First clinical experience with a mechanical valve with silver coating. J Heart Valve Dis 2000;9:123-129; disccusion 129-130.
    • (2000) J Heart Valve Dis , vol.9 , pp. 123-129
    • Brutel De La Riviere, A.1    Dossche, K.M.2    Birnbaum, D.E.3    Hacker, R.4
  • 14
    • 0036202242 scopus 로고    scopus 로고
    • Silver-coated endotracheal tubes associated with reduced bacterial burden in the lungs of mechanically ventilated dogs
    • DOI 10.1378/chest.121.3.863
    • Olson ME, Harmon BG, Kollef MH. Silver-coated endotracheal tubes associated with reduced bacterial burden in the lungs of mechanically ventilated dogs. Chest 2002;121:867-870. (Pubitemid 34251456)
    • (2002) Chest , vol.121 , Issue.3 SUPPL. , pp. 863-870
    • Olson, M.E.1    Harmon, B.G.2    Kollef, M.H.3
  • 15
    • 0033957912 scopus 로고    scopus 로고
    • Historical review of the use of silver in the treatment of burns. I. Early uses
    • Klasen HJ. Historical review of the use of silver in the treatment of burns. I. Early uses. Burns 2000;26:117-130.
    • (2000) Burns , vol.26 , pp. 117-130
    • Klasen, H.J.1
  • 16
    • 0030000110 scopus 로고    scopus 로고
    • Toxicological aspects of topical silver pharmaceuticals
    • Hollinger MA. Toxicological aspects of topical silver pharmaceuticals. Crit Rev Toxicol 1996;26:255-260. (Pubitemid 26197836)
    • (1996) Critical Reviews in Toxicology , vol.26 , Issue.3 , pp. 255-260
    • Hollinger, M.A.1
  • 18
    • 8544267224 scopus 로고
    • Experimental studies of metal implants coated with ceramics
    • (in Japanese).
    • Noda I, Makinouchi K. Experimental studies of metal implants coated with ceramics. Orthop Ceram Implants 1985;5:181-186 (in Japanese).
    • (1985) Orthop Ceram Implants , vol.5 , pp. 181-186
    • Noda, I.1    Makinouchi, K.2
  • 21
    • 0026028253 scopus 로고
    • Orthopaedic applications of hydroxyapatite
    • Oonishi H. Orthopaedic applications of hydroxyapatite. Biomaterials 1991;12:171-178.
    • (1991) Biomaterials , vol.12 , pp. 171-178
    • Oonishi, H.1
  • 24
    • 0036175102 scopus 로고    scopus 로고
    • Hydroxyapatite coating improves 8- To 10-year performance of the Link RS cementless femoral stem
    • DOI 10.1054/arth.2002.29395
    • Palm L, Jacobsson SA, Ivarsson I. Hydroxyapatite coating improves 8- to 10-year performance of the link RS cementless femoral stem. J Arthroplasty 2002;17:172-175. (Pubitemid 34160568)
    • (2002) Journal of Arthroplasty , vol.17 , Issue.2 , pp. 172-175
    • Palm, L.1    Jacobsson, S.-A.2    Ivarsson, I.3
  • 26
    • 84860895227 scopus 로고    scopus 로고
    • Antimicrobial products - Test for antimicrobial activity and efficacy
    • Japan: Japanese Standards Association
    • Japanese Industrial Standard (JIS) Z2801. Antimicrobial products - Test for antimicrobial activity and efficacy. Japan: Japanese Standards Association; 2000.
    • (2000) Japanese Industrial Standard (JIS) Z2801
  • 28
    • 65949089321 scopus 로고    scopus 로고
    • Testing method for metal release from metallic biomaterial
    • Japanese Industrial Standard (JIS) T 0304. Testing method for metal release from metallic biomaterial. Japanese Standards Association (JSA); 2002. http://www.jsa.or.jp/default-english.asp.
    • (2002) Japanese Industrial Standard (JIS) T 0304
  • 30
    • 65949116746 scopus 로고
    • Diagnosis and treatment policy for Infection of artificial joints
    • (in Japanese).
    • Ishii Y. Diagnosis and treatment policy for Infection of artificial joints. Joint Surg 1995;14:35-42 (in Japanese).
    • (1995) Joint Surg , vol.14 , pp. 35-42
    • Ishii, Y.1
  • 32
    • 0033394396 scopus 로고    scopus 로고
    • Anti-infective efficacy of silver-coated medical prostheses
    • DOI 10.1086/313561
    • Darouiche RO. Anti-infective efficacy of silver-coated medical prostheses. Clin Infect Dis 1999;29:1371-1377. (Pubitemid 30022725)
    • (1999) Clinical Infectious Diseases , vol.29 , Issue.6 , pp. 1371-1377
    • Darxouiche, R.O.1
  • 33
    • 0016161188 scopus 로고
    • The effect of silver ions on the respiratory chain of Escherichia coli
    • Bragg PD, Rainnie DJ. The effect of silver ions on the respiratory chain of Escherichia coli. Can J Microbiol 1974;20:883-889.
    • (1974) Can J Microbiol , vol.20 , pp. 883-889
    • Bragg, P.D.1    Rainnie, D.J.2
  • 35
    • 0033802325 scopus 로고    scopus 로고
    • Evaluation of antiseptic-impregnated central venous catheters for prevention of catheter-related infection in intensive care unit patients
    • Sheng WH, Ko WJ, Wang JT, Chang SC, Hsueh PR, Luh KT. Evaluation of antiseptic-impregnated central venous catheters for prevention of catheter-related infection in intensive care unit patients. Diagn Microbial Infect Dis 2000;38:1-5.
    • (2000) Diagn Microbial Infect Dis , vol.38 , pp. 1-5
    • Sheng, W.H.1    Ko, W.J.2    Wang, J.T.3    Chang, S.C.4    Hsueh, P.R.5    Luh, K.T.6
  • 36
    • 0029345023 scopus 로고
    • The development of new titanium arc-sprayed artificial joints
    • Fujisawa A, Noda I, Nishio Y, Okimatsu H. The development of new titanium arc-sprayed artificial joints. Mater Sci Eng C 1995;2:151-157.
    • (1995) Mater Sci Eng C , vol.2 , pp. 151-157
    • Fujisawa, A.1    Noda, I.2    Nishio, Y.3    Okimatsu, H.4
  • 38
    • 0029094727 scopus 로고
    • A character and aspect of hydroxyapatite coating by plasma spraying
    • (in Japanese).
    • Yamada K, Imamura K, Iwata H, Ito H, Maruno S. A character and aspect of hydroxyapatite coating by plasma spraying. J Jpn Orthop Assoc 1995;69:S1378 (in Japanese).
    • (1995) J Jpn Orthop Assoc , vol.69
    • Yamada, K.1    Imamura, K.2    Iwata, H.3    Ito, H.4    Maruno, S.5
  • 40
    • 38349179878 scopus 로고    scopus 로고
    • Study on Ag-HA coatings prepared by vacuum plasma spraying
    • Zheng X, Zeng Y, Ding C, Lee S, Zhu Z, Zhang F. Study on Ag-HA coatings prepared by vacuum plasma spraying. Mater Sci Forum 2007;544-545:841-844.
    • (2007) Mater Sci Forum , vol.544-545 , pp. 841-844
    • Zheng, X.1    Zeng, Y.2    Ding, C.3    Lee, S.4    Zhu, Z.5    Zhang, F.6
  • 42
    • 0027642518 scopus 로고
    • Apatite formation on theree kinds of bioactive material at an easy stage in vivo: A comparative study by transmission electron microscopy
    • Neo M, Nakamura T, Ohtsuki C, Kokubo T, Yamamuro T. Apatite formation on theree kinds of bioactive material at an easy stage in vivo: A comparative study by transmission electron microscopy. J Biomed Mater Res 1993;27:999-1006.
    • (1993) J Biomed Mater Res , vol.27 , pp. 999-1006
    • Neo, M.1    Nakamura, T.2    Ohtsuki, C.3    Kokubo, T.4    Yamamuro, T.5
  • 44
    • 32144437418 scopus 로고    scopus 로고
    • How useful is SBF in predicting in vivo bone bioactivity?
    • Kokubo T, Takadama H. How useful is SBF in predicting in vivo bone bioactivity? Biomaterials 2006;27:2907-2915.
    • (2006) Biomaterials , vol.27 , pp. 2907-2915
    • Kokubo, T.1    Takadama, H.2
  • 45
    • 0023253136 scopus 로고
    • Serum and urinary silver levels in thermal injury patients
    • Boosalis MG, McCall JT, Ahrenholz DH, Solem LD, McClain CJ. Serum and urinary silver levels in thermal injury patients. Surgery 1987;101:40-43. (Pubitemid 17218377)
    • (1987) Surgery , vol.101 , Issue.1 , pp. 40-43
    • Boosalis, M.G.1    McCall, J.T.2    Ahrenholz, D.H.3
  • 46
    • 65949110532 scopus 로고    scopus 로고
    • Silver-ceramic bactericide, Apacider A
    • (in Japanese).
    • Fujita K. Silver-ceramic bactericide, Apacider A. Func Mater 1997;17:41-44 (in Japanese).
    • (1997) Func Mater , vol.17 , pp. 41-44
    • Fujita, K.1
  • 47
    • 65949095589 scopus 로고    scopus 로고
    • Antibacterial Glass, mite control and amenity house
    • (in Japanese).
    • Yamamoto K. Antibacterial Glass, mite control and amenity house. Sumai 1996;17:19-21 (in Japanese).
    • (1996) Sumai , vol.17 , pp. 19-21
    • Yamamoto, K.1
  • 48
    • 9444243222 scopus 로고    scopus 로고
    • Metal Ion release from metal implants
    • Hanawa T. Metal Ion release from metal implants. Mater Sci Eng C 2004;24:745-752.
    • (2004) Mater Sci Eng C , vol.24 , pp. 745-752
    • Hanawa, T.1
  • 50
    • 0026709997 scopus 로고
    • Tentative reference values for gold, silver and platinum; Literature data analysis
    • Perrelli G, Piolatto G. Tentative reference values for gold, silver and platinum; Literature data analysis. Sci Total Environ 1992;120:93-96.
    • (1992) Sci Total Environ , vol.120 , pp. 93-96
    • Perrelli, G.1    Piolatto, G.2
  • 52
    • 0026066735 scopus 로고
    • Determination of silver in blood, urine, and tissues of volunteers and burn patients
    • Wan AT, Conyers RA, Coombs CJ, Masterton JP. Determination of silver in blood, urine, and tissues of volunteers and burn patients. Clin Chem 1991;37:1683-1687. (Pubitemid 21892727)
    • (1991) Clinical Chemistry , vol.37 , Issue.10 , pp. 1683-1687
    • Wan, A.T.1    Conyers, R.A.J.2    Coombs, C.J.3    Masterton, J.P.4
  • 53
    • 0032008208 scopus 로고    scopus 로고
    • Cytotoxicity evaluation of 43 metal salts using murine fibroblasts and osteoblastic cells
    • DOI 10.1002/(SICI)1097-4636(199802)39:2<331::AID-JBM22>3.0.CO;2-E
    • Yamamoto A, Honma R, Sumita M. Cytotoxicity evaluation of 43 metal salts using murine fibroblasts and osteoblastic cells. J Biomed Mater Res 1998;39:331-340. (Pubitemid 28060368)
    • (1998) Journal of Biomedical Materials Research , vol.39 , Issue.2 , pp. 331-340
    • Yamamoto, A.1    Honma, R.2    Sumita, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.