메뉴 건너뛰기




Volumn , Issue , 2008, Pages 309-312

Property changes of transformer oil during limiting states of transformer

Author keywords

[No Author keywords available]

Indexed keywords

ASSESSMENT OF PROCESS; COMMON OPERATIONS; COOLING MEDIUM; LABORATORY TESTING; LIMITING STATE; OPERATION CONDITIONS; PROPERTY CHANGES; SERVICE AVAILABILITY; TRANSFORMER OIL; UNBALANCED LOADING;

EID: 65949106582     PISSN: 00849162     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/CEIDP.2008.4772790     Document Type: Conference Paper
Times cited : (6)

References (12)
  • 1
    • 0037633348 scopus 로고    scopus 로고
    • Benefit and risk evaluation of power transformer overloading
    • Economic , GE Syprotec, Pointe-Claire, (Qu4bec), Canada, IEEE Volume 2, 28 Jan.-1 Feb. 2001
    • Chénier, R., Aubin, J; Economic "Benefit and Risk Evaluation of Power Transformer Overloading", GE Syprotec, Pointe-Claire, (Qu4bec), Canada, Power Engineering Society Winter Meeting, 2001. IEEE Volume 2, 28 Jan.-1 Feb. 2001 Page(s): 459 - 462 vol.2.
    • (2001) Power Engineering Society Winter Meeting , vol.2 , pp. 459-462
    • Chénier, R.1    Aubin, J.2
  • 3
    • 0025240168 scopus 로고
    • Development of oil-dissolved hydrogen gas detector for diagnosis of transformers
    • Jan.
    • Y. Inoue, K. Suganuma, M. Kamba, and M. Kikkawa, "Development of oil-dissolved hydrogen gas detector for diagnosis of transformers," IEEE Trans. Power Delivery, vol. 5, pp. 226-232, Jan. 1995.
    • (1995) IEEE Trans. Power Delivery , vol.5 , pp. 226-232
    • Inoue, Y.1    Suganuma, K.2    Kamba, M.3    Kikkawa, M.4
  • 4
    • 0020190736 scopus 로고
    • Oil additives for the evaluation of hot spot temperature in power transformers during overload tests
    • [see also Dielectrics and Electrical Insulation, IEEE Transactions on] Oct.
    • Duval, M.; Aubin, J.; Giguere, Y.; Pare, G.; Langhame, Y.; Oil Additives for the Evaluation of Hot Spot Temperature in Power Transformers During Overload Tests. Electrical Insulation, IEEE Transactions on [see also Dielectrics and Electrical Insulation, IEEE Transactions on] Volume EI-17, Issue 5, Oct. 1982 Page(s): 414-422.
    • (1982) Electrical Insulation, IEEE Transactions on , vol.EI-17 , Issue.5 , pp. 414-422
    • Duval, M.1    Aubin, J.2    Giguere, Y.3    Pare, G.4    Langhame, Y.5
  • 7
    • 65949110617 scopus 로고    scopus 로고
    • T/Guard System for Transformer Hot Spot Monitoring, [online], [cit. 13.6.2008]
    • T/Guard System for Transformer Hot Spot Monitoring, Neoptix, [online], [cit. 13.6.2008] WWW 〈http://www.neoptix.com/t-guard.asp〉
  • 8
    • 65949113879 scopus 로고    scopus 로고
    • Hydran M2 Monitoring System, [online], [cit. 13.6.2008]
    • Hydran M2 Monitoring System, GE Energy, [online], [cit. 13.6.2008] WWW 〈http://www.gepower.com/prod-serv/products/substation-md/en/ hydran-exchange.htm〉
  • 9
    • 65949113655 scopus 로고    scopus 로고
    • LOVATO DMK, [online], [cit. 5. 5. 2008]
    • LOVATO DMK, [online], [cit. 5. 5. 2008] WWW 〈http://www.lovato.cz/ katalog/Lovato/clanky/DMK.pdf〉
  • 11
    • 65949097540 scopus 로고    scopus 로고
    • Diagnostic and monitoring of power transformers
    • Zilina
    • Gutten, M.: "Diagnostic and Monitoring of Power Transformers", 5-th International Conference Elektro 2004, Zilina 2004, p . 300-301
    • (2004) 5-th International Conference Elektro 2004 , pp. 300-301
    • Gutten, M.1
  • 12
    • 0029509964 scopus 로고
    • State of water in hydrocarbon liquids and its effect onconductivity [transformer oil]
    • December ISSN: 1070-9878
    • Itahashi, S. Mitsui, H. Sato, T. Sone, M. "State of water in hydrocarbon liquids and its effect onconductivity [transformer oil]", IEEE Transactions on Dielectrics and Electrical Insulation, December 1995, Volume: 2, page(s): 1117-1122, ISSN: 1070-9878.
    • (1995) IEEE Transactions on Dielectrics and Electrical Insulation , vol.2 , pp. 1117-1122
    • Itahashi, S.1    Mitsui, H.2    Sato, T.3    Sone, M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.