메뉴 건너뛰기




Volumn 25, Issue 8, 2008, Pages 1454-1462

First-year operation of a new water vapor Raman lidar at the JPL Table Mountain Facility, California

Author keywords

[No Author keywords available]

Indexed keywords

CALIFORNIA; CURRENT SYSTEM; FIRST-YEAR; JET PROPULSION LABORATORY; LIDAR MEASUREMENTS; LIDAR PROFILES; LIDAR RECEIVERS; LOWER STRATOSPHERE; RAMAN LIDAR; UPPER TROPOSPHERE; WATER VAPOR MIXING RATIO; WATER VAPOR PROFILE;

EID: 65949088588     PISSN: 07390572     EISSN: None     Source Type: Journal    
DOI: 10.1175/2007JTECHA978.1     Document Type: Conference Paper
Times cited : (21)

References (11)
  • 1
    • 0343750717 scopus 로고    scopus 로고
    • Stratospheric water vapor changes as a possible contributor to observed stratospheric cooling
    • de Forster, P. M., and K. P. Shine, 1999: Stratospheric water vapor changes as a possible contributor to observed stratospheric cooling. Geophys. Res. Lett., 26, 3309-3312.
    • (1999) Geophys. Res. Lett , vol.26 , pp. 3309-3312
    • de Forster, P.M.1    Shine, K.P.2
  • 2
    • 0020927852 scopus 로고
    • Formulations for the thermodynamic properties of the saturated phases of H2O from 173.15K to 473.15K
    • 2A
    • Hyland, R. W., and A. Wexler, 1983: Formulations for the thermodynamic properties of the saturated phases of H2O from 173.15K to 473.15K. ASHRAE Trans., 89(2A), 500-519.
    • (1983) ASHRAE Trans , vol.89 , pp. 500-519
    • Hyland, R.W.1    Wexler, A.2
  • 3
    • 65949091016 scopus 로고    scopus 로고
    • SPARC/IOC/ICSU/ WCRP assessment of upper tropospheric and stratospheric water vapor
    • Kley, D, J. M. Russell III, and C. Phillips, Eds, 312 pp
    • Kley, D., J. M. Russell III, and C. Phillips, Eds., 2000: SPARC/IOC/ICSU/ WCRP assessment of upper tropospheric and stratospheric water vapor. SPARC Rep. 2, 312 pp.
    • (2000) SPARC Rep , vol.2
  • 4
    • 5044225294 scopus 로고    scopus 로고
    • Development and validation of a time-lag correction for Vaisala radiosonde humidity measurements
    • Miloshevich, L. M., A. Paukkunen, H. Vömel, and S. J. Oltmans, 2004: Development and validation of a time-lag correction for Vaisala radiosonde humidity measurements. J. Atmos. Oceanic Technol., 21, 1305-1327.
    • (2004) J. Atmos. Oceanic Technol , vol.21 , pp. 1305-1327
    • Miloshevich, L.M.1    Paukkunen, A.2    Vömel, H.3    Oltmans, S.J.4
  • 5
    • 33745435491 scopus 로고    scopus 로고
    • Absolute accuracy of water vapor measurements from six operational radiosonde types launched during AWEX-G, and implications for AIRS validation
    • doi:10.1029/2005JD006083
    • Miloshevich, L. M., H. Voemel, D. N. Whiteman, B. M. Lesht, F. J. Schmidlin, and F. Russo, 2006: Absolute accuracy of water vapor measurements from six operational radiosonde types launched during AWEX-G, and implications for AIRS validation. J. Geophys. Res., 111, D09S10, doi:10.1029/2005JD006083.
    • (2006) J. Geophys. Res , vol.111
    • Miloshevich, L.M.1    Voemel, H.2    Whiteman, D.N.3    Lesht, B.M.4    Schmidlin, F.J.5    Russo, F.6
  • 7
    • 0028797558 scopus 로고
    • Increase in lower stratospheric water vapor at a midlatitude Northern Hemisphere site from 1981 to 1994
    • Oltmans, S. J., and D. J. Hofmann, 1995: Increase in lower stratospheric water vapor at a midlatitude Northern Hemisphere site from 1981 to 1994. Nature, 374, 146-149.
    • (1995) Nature , vol.374 , pp. 146-149
    • Oltmans, S.J.1    Hofmann, D.J.2
  • 8
    • 0005346556 scopus 로고    scopus 로고
    • Methodology for the independent calibration of Raman backscatter water vapor lidar systems
    • Sherlock, V., A. Garnier, A. Hauchecorne, and P. Keckhut, 1999a: Methodology for the independent calibration of Raman backscatter water vapor lidar systems. Appl. Opt., 38, 5816-5837.
    • (1999) Appl. Opt , vol.38 , pp. 5816-5837
    • Sherlock, V.1    Garnier, A.2    Hauchecorne, A.3    Keckhut, P.4
  • 9
    • 0001414654 scopus 로고    scopus 로고
    • Implementation and validation of a Raman lidar measurement of middle and upper tropospheric water vapor
    • Sherlock, V., A. Garnier, A. Hauchecorne, and P. Keckhut, 1999b: Implementation and validation of a Raman lidar measurement of middle and upper tropospheric water vapor. Appl. Opt., 38, 5838-5850.
    • (1999) Appl. Opt , vol.38 , pp. 5838-5850
    • Sherlock, V.1    Garnier, A.2    Hauchecorne, A.3    Keckhut, P.4
  • 10
    • 0024200270 scopus 로고
    • Humidity measurements in the free troposphere using Raman backscatter
    • Vaughan, G., D. P. Waring, L. Thomas, and V. Mitev, 1988: Humidity measurements in the free troposphere using Raman backscatter. Quart. J. Roy. Meteor. Soc., 114, 1471-1484.
    • (1988) Quart. J. Roy. Meteor. Soc , vol.114 , pp. 1471-1484
    • Vaughan, G.1    Waring, D.P.2    Thomas, L.3    Mitev, V.4
  • 11
    • 34249742071 scopus 로고    scopus 로고
    • Accuracy of tropospheric and stratospheric water vapor measurements by the Cryogenic Frost point Hygrometer (CFH): Instrumental details and observations
    • doi:10.1029/2006JD007224
    • Vömel, H., D. David, and K. Smith, 2007: Accuracy of tropospheric and stratospheric water vapor measurements by the Cryogenic Frost point Hygrometer (CFH): Instrumental details and observations. J. Geophys. Res., 112, D08305, doi:10.1029/2006JD007224.
    • (2007) J. Geophys. Res , vol.112
    • Vömel, H.1    David, D.2    Smith, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.