-
1
-
-
0019163790
-
Cerebral blood flow determination by rapid-sequence computed tomography; theoretical analysis
-
Axel L. Cerebral blood flow determination by rapid-sequence computed tomography; theoretical analysis. Radiology 1980; 137: 679-86.
-
(1980)
Radiology
, vol.137
, pp. 679-686
-
-
Axel, L.1
-
2
-
-
0020659564
-
Tissue mean transit time from dynamic computed tomography by a simple deconvolution technique
-
Axel L. Tissue mean transit time from dynamic computed tomography by a simple deconvolution technique. Invest Radiol 1983; 18: 94-9.
-
(1983)
Invest Radiol
, vol.18
, pp. 94-99
-
-
Axel, L.1
-
3
-
-
0025765943
-
Measurement of tissue perfusion by dynamic computed tomography
-
Miles KA. Measurement of tissue perfusion by dynamic computed tomography. Br J Radiol 1991; 64: 409-12.
-
(1991)
Br J Radiol
, vol.64
, pp. 409-412
-
-
Miles, K.A.1
-
4
-
-
0027882557
-
Contrast bolus dynamic computed tomography for the measurement of solid organ perfusion
-
Blomley MJK, Coulden R, Bufkin CRT et al. Contrast bolus dynamic computed tomography for the measurement of solid organ perfusion. Invest Radiol 1993; 28 (Suppl 5): S72-7.
-
(1993)
Invest Radiol
, vol.28
, pp. S72-S77
-
-
Blomley, M.J.K.1
Coulden, R.2
Bufkin, C.R.T.3
-
5
-
-
0030888256
-
Bolus dynamics: Theoretical and experimental aspects
-
Blomley MJK, Dawson P. Bolus dynamics: theoretical and experimental aspects. Br J Radiol 1997; 70: 351-9.
-
(1997)
Br J Radiol
, vol.70
, pp. 351-359
-
-
Blomley, M.J.K.1
Dawson, P.2
-
6
-
-
0029835013
-
Contrast agents as extra-cellular fluid space markers: Adaptation of the central volume theorem
-
Dawson P, Blomley MJK. Contrast agents as extra-cellular fluid space markers: adaptation of the central volume theorem. Br J Radiol 1996; 69: 717-22.
-
(1996)
Br J Radiol
, vol.69
, pp. 717-722
-
-
Dawson, P.1
Blomley, M.J.K.2
-
7
-
-
0031742176
-
An adiabatic approximation to the tissue homogeneity model for water exchange in the brain I. Theoretical derivation
-
St Lawrence K, Lee T-Y. An adiabatic approximation to the tissue homogeneity model for water exchange in the brain I. Theoretical derivation. J Cereb Blood Flow Metab 1998; 18: 1365-77.
-
(1998)
J Cereb Blood Flow Metab
, vol.18
, pp. 1365-1377
-
-
St Lawrence, K.1
Lee, T.-Y.2
-
8
-
-
0031797063
-
An adiabatic approximation to the tissue homogeneity model for water exchange in the brain II. Experimental validation
-
St Lawrence K, Lee T-Y. An adiabatic approximation to the tissue homogeneity model for water exchange in the brain II. Experimental validation. J Cereb Blood Flow Metab 1998; 18: 1378-85.
-
(1998)
J Cereb Blood Flow Metab
, vol.18
, pp. 1378-1385
-
-
St Lawrence, K.1
Lee, T.-Y.2
-
9
-
-
0033506699
-
Dynamic CT measurement of cerebral blood flow: A validation study
-
Cenic A, Nabavi DG, Craen RA, Gelb AW, Lee T-Y. Dynamic CT measurement of cerebral blood flow: a validation study. AJNR Am J Neuroradiol 1999; 20: 63-73.
-
(1999)
AJNR Am J Neuroradiol
, vol.20
, pp. 63-73
-
-
Cenic, A.1
Nabavi, D.G.2
Craen, R.A.3
Gelb, A.W.4
Lee, T.-Y.5
-
10
-
-
0034069356
-
A CT method to measure hemodynamics in brain tumors: Validation and application to cerebral blood flow maps
-
Cenic A, Nabavi DG, Craen RA, Gelb AW, Lee T-Y. A CT method to measure hemodynamics in brain tumors: validation and application to cerebral blood flow maps. AJNR Am J Neuroradiol 2000; 21: 462-70.
-
(2000)
AJNR Am J Neuroradiol
, vol.21
, pp. 462-470
-
-
Cenic, A.1
Nabavi, D.G.2
Craen, R.A.3
Gelb, A.W.4
Lee, T.-Y.5
-
11
-
-
0031844425
-
Evaluation of the ratio of cerebral blood flow to cerebral blood volume as an index of local cerebral perfusion pressure
-
Schumann P, Touzani O, Young AR et al. Evaluation of the ratio of cerebral blood flow to cerebral blood volume as an index of local cerebral perfusion pressure. Brain 1998; 121: 1369-79.
-
(1998)
Brain
, vol.121
, pp. 1369-1379
-
-
Schumann, P.1
Touzani, O.2
Young, A.R.3
-
13
-
-
78651133453
-
The permeability of capillaries in various organs as determined by use of the ‘indicator diffusion’ method
-
Crone C. The permeability of capillaries in various organs as determined by use of the ‘indicator diffusion’ method. Acta Physiol Scand 1963; 58: 292-305.
-
(1963)
Acta Physiol Scand
, vol.58
, pp. 292-305
-
-
Crone, C.1
-
14
-
-
0013920609
-
A model for capillary exchange
-
Johnson JA, Wilson TA. A model for capillary exchange. Am J Physiol 1966; 210: 1299-303.
-
(1966)
Am J Physiol
, vol.210
, pp. 1299-1303
-
-
Johnson, J.A.1
Wilson, T.A.2
-
15
-
-
0024512835
-
Kinetic analysis of cerebrovascular transport based on indicator diffusion technique
-
Sawada Y, Patlak CS, Blasberg RG. Kinetic analysis of cerebrovascular transport based on indicator diffusion technique. Am J Physiol 1989; 256: H794-812.
-
(1989)
Am J Physiol
, vol.256
, pp. H794-H812
-
-
Sawada, Y.1
Patlak, C.S.2
Blasberg, R.G.3
-
16
-
-
13344292421
-
Transport of potassium-42 from blood to tissue in isolated mammalian skeletal muscle
-
Renkin EM. Transport of potassium-42 from blood to tissue in isolated mammalian skeletal muscle. Am J Physiol 1959; 197: 1205-10
-
(1959)
Am J Physiol
, vol.197
, pp. 1205-1210
-
-
Renkin, E.M.1
-
17
-
-
77049181625
-
On the theory of the indicator dilution method for measurement of blood flow and volume
-
Meier P, Zierler KL. On the theory of the indicator dilution method for measurement of blood flow and volume. J Appl Physiol 1954; 6: 731-44.
-
(1954)
J Appl Physiol
, vol.6
, pp. 731-744
-
-
Meier, P.1
Zierler, K.L.2
-
18
-
-
0015860134
-
The interpretation of mean transit time measurements for multiphase tissue systems
-
Robert GW, Larson KB, Spaeth EE. The interpretation of mean transit time measurements for multiphase tissue systems. J Theor Biol 1973; 39: 447-75.
-
(1973)
J Theor Biol
, vol.39
, pp. 447-475
-
-
Robert, G.W.1
Larson, K.B.2
Spaeth, E.E.3
-
19
-
-
0023030802
-
Studies on regional cerebral pH in patients with cerebral tumours using continuous inhalation of 11CO2 and positron emission tomography
-
Brooks DJ, Thomas DG, Marshall J, Jones T. Studies on regional cerebral pH in patients with cerebral tumours using continuous inhalation of 11CO2 and positron emission tomography. J Cereb Blood Flow Metab 1986; 6: 529-35.
-
(1986)
J Cereb Blood Flow Metab
, vol.6
, pp. 529-535
-
-
Brooks, D.J.1
Thomas, D.G.2
Marshall, J.3
Jones, T.4
-
20
-
-
0022552020
-
Regional lung hematocrit in humans using positron emission tomography
-
Brudin LH, Valind SO, Rhodes CG, Turton DR, Hughes JM. Regional lung hematocrit in humans using positron emission tomography. J Appl Physiol 1986; 60:1155-63.
-
(1986)
J Appl Physiol
, vol.60
, pp. 1155-1163
-
-
Brudin, L.H.1
Valind, S.O.2
Rhodes, C.G.3
Turton, D.R.4
Hughes, J.M.5
-
21
-
-
10144241680
-
Measurement of regional cerebral plasma pool and hematocrit with copper-62-labeled HSA-DTS
-
Okazawa H, Yonekura Y, Fujibayashi Y et al. Measurement of regional cerebral plasma pool and hematocrit with copper-62-labeled HSA-DTS. J Nucl Med 1996; 37: 1080-5.
-
(1996)
J Nucl Med
, vol.37
, pp. 1080-1085
-
-
Okazawa, H.1
Yonekura, Y.2
Fujibayashi, Y.3
-
22
-
-
84996051649
-
Cerebral blood flow and cerebral hematocrit in patients with cerebral ischemia measured by single-photon emission computed tomography
-
198
-
Sakai F, Igarashi H, Suzuki S, Tazaki Y. Cerebral blood flow and cerebral hematocrit in patients with cerebral ischemia measured by single-photon emission computed tomography. Acta Neurol Scand 198; 127 (Suppl): 9-13.
-
Acta Neurol Scand
, vol.127
, pp. 9-13
-
-
Sakai, F.1
Igarashi, H.2
Suzuki, S.3
Tazaki, Y.4
-
23
-
-
0025314256
-
Quantitative computed tomography of the brain with xenon enhancement: A phantom study with the GE9800 scanner
-
Lee TY, Ellis RJ, Dunscombe PB et al. Quantitative computed tomography of the brain with xenon enhancement: a phantom study with the GE9800 scanner. Phys Med Biol 1990; 35: 925-35.
-
(1990)
Phys Med Biol
, vol.35
, pp. 925-935
-
-
Lee, T.Y.1
Ellis, R.J.2
Dunscombe, P.B.3
-
24
-
-
0002110830
-
Definitions and terminology for indicator dilution methods
-
In: Crone C, Lassen NA, eds., Copenhagen: Munskgaard
-
Bassingthwaighte JB, Chinard FP, Crone C, Lassen NA, Perl W. Definitions and terminology for indicator dilution methods. In: Crone C, Lassen NA, eds. Capillary Permeability. Copenhagen: Munskgaard 1970: 665-9.
-
(1970)
Capillary Permeability
, pp. 665-669
-
-
Bassingthwaighte, J.B.1
Chinard, F.P.2
Crone, C.3
Lassen, N.A.4
Perl, W.5
-
25
-
-
0023617359
-
Noninvasive measurement of blood flow and extraction fraction
-
Peters AM, Gunasekera RD, Henderson BL et. al. Noninvasive measurement of blood flow and extraction fraction. Nucl Med Commun 1987; 8: 823-37.
-
(1987)
Nucl Med Commun
, vol.8
, pp. 823-837
-
-
Peters, A.M.1
Gunasekera, R.D.2
Henderson, B.L.3
-
26
-
-
0025765943
-
Measurement of tissue perfusion by dynamic computed tomography
-
Miles KA. Measurement of tissue perfusion by dynamic computed tomography. Br J Radiol 1991; 64: 409-12.
-
(1991)
Br J Radiol
, vol.64
, pp. 409-412
-
-
Miles, K.A.1
-
27
-
-
0033778716
-
Application of CT in the investigation of angiogenesis in oncology
-
Miles KA, Charnsangavej C, Lee FT et al. Application of CT in the investigation of angiogenesis in oncology. Acad Radiol 2000; 7: 840-50.
-
(2000)
Acad Radiol
, vol.7
, pp. 840-850
-
-
Miles, K.A.1
Charnsangavej, C.2
Lee, F.T.3
-
28
-
-
0344417098
-
Perfusion measurements of the brain: Using dynamic CT for the quantitative assessment of cerebral ischemia in acute stroke
-
Klotz E, Konig M. Perfusion measurements of the brain: using dynamic CT for the quantitative assessment of cerebral ischemia in acute stroke. Eur J Radiol 1999; 30: 170-84.
-
(1999)
Eur J Radiol
, vol.30
, pp. 170-184
-
-
Klotz, E.1
Konig, M.2
-
29
-
-
0001922222
-
The determination of cerebral blood flow in man by the use of nitrous oxide in low concentrations
-
Kety SS, Schmidt CT. The determination of cerebral blood flow in man by the use of nitrous oxide in low concentrations. Am J Physiol 1945; 143: 53-61.
-
(1945)
Am J Physiol
, vol.143
, pp. 53-61
-
-
Kety, S.S.1
Schmidt, C.T.2
-
30
-
-
0020956774
-
Graphical evaluation of blood-to-brain transfer constants from multiple-time uptake data
-
Patlak CS, Blasberg RG, Fenstermacher JD. Graphical evaluation of blood-to-brain transfer constants from multiple-time uptake data. J Cereb Blood Metab 1983; 3: 1-7.
-
(1983)
J Cereb Blood Metab
, vol.3
, pp. 1-7
-
-
Patlak, C.S.1
Blasberg, R.G.2
Fenstermacher, J.D.3
-
31
-
-
0022389649
-
Graphical evaluation of blood-to-brain transfer constants from multiple-time uptake data. Generalizations
-
Patlak CS, Blasberg RG. Graphical evaluation of blood-to-brain transfer constants from multiple-time uptake data. Generalizations. J Cereb Blood Metab 1985; 5: 584-90.
-
(1985)
J Cereb Blood Metab
, vol.5
, pp. 584-590
-
-
Patlak, C.S.1
Blasberg, R.G.2
-
32
-
-
0026045642
-
A method to quantitatively measure transcapillary transport of iodinated compounds in canine brain tumors with computed tomography
-
Groothuis DR, Lapin GD, Vriesendorp FJ, Mikhael MA, Patlak CS. A method to quantitatively measure transcapillary transport of iodinated compounds in canine brain tumors with computed tomography. J Cereb Blood Flow Metab 1991; 11: 939-48.
-
(1991)
J Cereb Blood Flow Metab
, vol.11
, pp. 939-948
-
-
Groothuis, D.R.1
Lapin, G.D.2
Vriesendorp, F.J.3
Mikhael, M.A.4
Patlak, C.S.5
-
33
-
-
0025946335
-
Quantitative measurements of capillary transport in human brain tumors by computed tomography
-
Groothuis DR, Vriesendorp FJ, Kupfer B et al. Quantitative measurements of capillary transport in human brain tumors by computed tomography. Ann Neurol 1991; 30: 581-8.
-
(1991)
Ann Neurol
, vol.30
, pp. 581-588
-
-
Groothuis, D.R.1
Vriesendorp, F.J.2
Kupfer, B.3
-
35
-
-
0032865983
-
Tumour angiogenesis and its relation to contrast enhancement on computerised tomography: A review
-
Miles KA. Tumour angiogenesis and its relation to contrast enhancement on computerised tomography: a review: Eur J Radiol 1999; 30: 198-205.
-
(1999)
Eur J Radiol
, vol.30
, pp. 198-205
-
-
Miles, K.A.1
-
36
-
-
0033812331
-
Delay and dispersion effects in dynamic susceptibility contrast MRI: Simulations using singular value decomposition
-
Calamante F, Gadian DG, Connelly A. Delay and dispersion effects in dynamic susceptibility contrast MRI: simulations using singular value decomposition. Magn Reson Med 2000; 44: 466-73.
-
(2000)
Magn Reson Med
, vol.44
, pp. 466-473
-
-
Calamante, F.1
Gadian, D.G.2
Connelly, A.3
-
37
-
-
0019418553
-
Liver blood flow. I. Intrinsic and nervous control of liver blood flow
-
Richardson PD, Withrington PG. Liver blood flow. I. Intrinsic and nervous control of liver blood flow. Gastroenterology 1981; 81: 159-73.
-
(1981)
Gastroenterology
, vol.81
, pp. 159-173
-
-
Richardson, P.D.1
Withrington, P.G.2
-
38
-
-
0001604650
-
Direct measurement of hepatic blood flow in surgical patients: With related observations on hepatic flow dynamics in experimental animals
-
Schenk W Jr, McDonald J, McDonald K, Drapanas T. Direct measurement of hepatic blood flow in surgical patients: with related observations on hepatic flow dynamics in experimental animals. Ann Surg 1962; 156: 463-71.
-
(1962)
Ann Surg
, vol.156
, pp. 463-471
-
-
Schenk, W.1
McDonald, J.2
McDonald, K.3
Drapanas, T.4
-
39
-
-
33744780453
-
Correlation between hepatic tumor blood flow and glucose utilization in a rabbit liver tumor model
-
Stewart EE, Chen X, Hadway J, Lee T-Y. Correlation between hepatic tumor blood flow and glucose utilization in a rabbit liver tumor model. Radiology 2006; 239: 740-50.
-
(2006)
Radiology
, vol.239
, pp. 740-750
-
-
Stewart, E.E.1
Chen, X.2
Hadway, J.3
Lee, T.-Y.4
-
40
-
-
0036098275
-
Dynamic, contrast-enhanced CT of human brain tumors: Quantitative assessment of blood volume, blood flow, and microvascular permeability. Report of Two Cases
-
Roberts H, Roberts T, Lee T-Y, Dillon W. Dynamic, contrast-enhanced CT of human brain tumors: quantitative assessment of blood volume, blood flow, and microvascular permeability. Report of Two Cases. AJNR Am J Neuroradiol 2002; 23: 828-32.
-
(2002)
AJNR Am J Neuroradiol
, vol.23
, pp. 828-832
-
-
Roberts, H.1
Roberts, T.2
Lee, T.-Y.3
Dillon, W.4
-
41
-
-
17744392419
-
Monitoring cerebral perfusion flow after subarachnoid hemorrhage using CT
-
Nabavi DG, LeBlanc LM, Baxter B et al. Monitoring cerebral perfusion flow after subarachnoid hemorrhage using CT. Neuroradiology 2001; 43: 7-16.
-
(2001)
Neuroradiology
, vol.43
, pp. 7-16
-
-
Nabavi, D.G.1
LeBlanc, L.M.2
Baxter, B.3
-
42
-
-
0025314256
-
Quantitative computed tomography of the brain with xenon enhancement: A phantom study with the GE9800 scanner
-
Lee TY, Ellis RJ, Dunscombe PB et al. Quantitative computed tomography of the brain with xenon enhancement: a phantom study with the GE9800 scanner. Phys Med Biol 1990; 35: 925-35.
-
(1990)
Phys Med Biol
, vol.35
, pp. 925-935
-
-
Lee, T.Y.1
Ellis, R.J.2
Dunscombe, P.B.3
-
43
-
-
0033730930
-
Using 80 kVp versus 120 kVp in perfusion CT measurement of regional cerebral blood flow
-
Wintermark M, Maeder P, Verdun FR et al. Using 80 kVp versus 120 kVp in perfusion CT measurement of regional cerebral blood flow. AJNR Am J Neuroradiol 2000; 21: 1881-4.
-
(2000)
AJNR Am J Neuroradiol
, vol.21
, pp. 1881-1884
-
-
Wintermark, M.1
Maeder, P.2
Verdun, F.R.3
-
44
-
-
17044401426
-
Measurement of radiation dose in cerebral CT perfusion study
-
Hirata M, Sugawara Y, Fukutomi Y et al. Measurement of radiation dose in cerebral CT perfusion study. Radiat Med 2005; 23: 97-103.
-
(2005)
Radiat Med
, vol.23
, pp. 97-103
-
-
Hirata, M.1
Sugawara, Y.2
Fukutomi, Y.3
-
45
-
-
0033735138
-
Technique factors and image quality as functions of patient weight at abdominal CT
-
Huda W, Scalzetti EM, Levin G. Technique factors and image quality as functions of patient weight at abdominal CT. Radiology 2000; 217: 430-5.
-
(2000)
Radiology
, vol.217
, pp. 430-435
-
-
Huda, W.1
Scalzetti, E.M.2
Levin, G.3
-
46
-
-
2442666607
-
Quantitative evaluation of perfusion and permeability of peripheral tumours using contrast-enhanced computed tomography
-
Pollard RE, Garcia TC, Stieger SM et al. Quantitative evaluation of perfusion and permeability of peripheral tumours using contrast-enhanced computed tomography. Invest Radiol 2004; 39: 340-9.
-
(2004)
Invest Radiol
, vol.39
, pp. 340-349
-
-
Pollard, R.E.1
Garcia, T.C.2
Stieger, S.M.3
-
48
-
-
0014680284
-
Increased vascular permeability in the primary cutaneous allograft response in the rat
-
Lykke AW, Cummings R. Increased vascular permeability in the primary cutaneous allograft response in the rat. Experientia 1969; 25: 1287-8.
-
(1969)
Experientia
, vol.25
, pp. 1287-1288
-
-
Lykke, A.W.1
Cummings, R.2
-
49
-
-
0035739245
-
Functional CT imaging of angiogenesis in rabbit VX2 soft tissue
-
Purdie TG, Henderson E, Lee TY. Functional CT imaging of angiogenesis in rabbit VX2 soft tissue. Phys Med Biol 2001; 46: 3161-75.
-
(2001)
Phys Med Biol
, vol.46
, pp. 3161-3175
-
-
Purdie, T.G.1
Henderson, E.2
Lee, T.Y.3
-
50
-
-
84908219488
-
Statistical methods for assessing agreement between two methods of clinical measurement
-
Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 1: 307-10.
-
(1986)
Lancet
, vol.1
, pp. 307-310
-
-
Bland, J.M.1
Altman, D.G.2
-
51
-
-
0028040599
-
Statistical methodology for the concurrent assessment of interrater and intrarater reliability: Using goniometric measurements as an example
-
Eliasziw M, Young SL, Woodbury MG, Fryday-Field K. Statistical methodology for the concurrent assessment of interrater and intrarater reliability: using goniometric measurements as an example. Phys Ther 1994; 74: 777-88.
-
(1994)
Phys Ther
, vol.74
, pp. 777-788
-
-
Eliasziw, M.1
Young, S.L.2
Woodbury, M.G.3
Fryday-Field, K.4
-
52
-
-
33746173822
-
Quantitative colorectal cancer perfusion measurement by multidetector-row CT: Does greater tumour coverage improve measurement reproducibility?
-
Goh V, Halligan S, Gartner L, Bassett P, Bartram CI. Quantitative colorectal cancer perfusion measurement by multidetector-row CT: does greater tumour coverage improve measurement reproducibility? Br J Radiol 2006; 79: 578-83.
-
(2006)
Br J Radiol
, vol.79
, pp. 578-583
-
-
Goh, V.1
Halligan, S.2
Gartner, L.3
Bassett, P.4
Bartram, C.I.5
-
53
-
-
33748992003
-
Quantitative assessment of lung cancer perfusion using MDCT: Does measurement reproducibility improve with greater tumor volume coverage?
-
Ng QS, Goh V, Klotz E et al. Quantitative assessment of lung cancer perfusion using MDCT: does measurement reproducibility improve with greater tumor volume coverage? Am J Roentgenol 2006; 187: 1079-84.
-
(2006)
Am J Roentgenol
, vol.187
, pp. 1079-1084
-
-
Ng, Q.S.1
Goh, V.2
Klotz, E.3
-
54
-
-
0028648280
-
Tumor blood flow measured using dynamic computed tomography
-
Hattori H, Miyoshi T, Okada J et al. Tumor blood flow measured using dynamic computed tomography. Invest Radiol 1994; 29: 873-6.
-
(1994)
Invest Radiol
, vol.29
, pp. 873-876
-
-
Hattori, H.1
Miyoshi, T.2
Okada, J.3
|