메뉴 건너뛰기




Volumn 60, Issue 2, 2009, Pages 57-68

Wireless measurement system for non-invasive biomedical monitoring of psycho-physiological processes

Author keywords

Biomedical monitoring; IDA microelectrodes; Non invasive monitoring; Physiologic processes; Psychogalvanic reflex; Skin conductivity measurement

Indexed keywords


EID: 65749100361     PISSN: 13353632     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (10)

References (14)
  • 4
    • 0037998069 scopus 로고
    • Noninvasive Biomedical Sensors on the Biology - Interface of Human Skin
    • Proceedings of the 7th Interna tional IMECO TC-13 Conference on Measurement in Clinical Medicine: Model Based Biomeasurement
    • WEIS, M.-DANILLA, T.-MATAY, L.-HRKÚT, P.-KÁ- KOŠ, J.: Noninvasive Biomedical Sensors on the Biology - Interface of Human Skin, Proceedings of the 7th Interna tional IMECO TC-13 Conference on Measurement in Clinical Medicine: Model Based Biomeasurement, Stará Lesná, 1995, pp. 89-91.
    • (1995) Stará Lesná , pp. 89-91
    • Weis, M.1    Danilla, T.2    Matay, L.3    Hrkút, P.4    Kákoš, J.5
  • 6
    • 3042579095 scopus 로고    scopus 로고
    • Massachusetts Institute of Technology, USA
    • GERASIMOV, V.: Every Sign of Life, Massachusetts Institute of Technology, USA, 2003.
    • (2003) Every Sign of Life
    • Gerasimov, V.1
  • 7
    • 0012699597 scopus 로고    scopus 로고
    • Technical Report MS-CIS-99-29, University of Pennsylvania, USA
    • ANGELOPOULOU, E.: The Reflectance Spectrum of Human Skin, Technical Report MS-CIS-99-29, University of Pennsylva- nia, USA, 1999, pp. 1-14.
    • (1999) The Reflectance Spectrum of Human Skin , pp. 1-14
    • Angelopoulou, E.1
  • 8
    • 0038615936 scopus 로고    scopus 로고
    • Thin Film Non-Symmetric Microelectrode Array for Impedance Monitoring of Human Skin
    • IVANIC, R.-NOVOTNY, I.-REHACEK, V.-TVAROZEK, V.-WEIS, M.: Thin Film Non-Symmetric Microelectrode Array for Impedance Monitoring of Human Skin, Thin Solid Films 433 (2003),332-336.
    • (2003) Thin Solid Films , vol.433 , pp. 332-336
    • Ivanic, R.1    Novotny, I.2    Rehacek, V.3    Tvarozek, V.4    Weis, M.5
  • 10
    • 65749087561 scopus 로고    scopus 로고
    • Sensitive and Accurate Measurement Environment for Continuous Biomedical Monitoring using Microelectrodes
    • In: 6th International Conference on Measurement - Smolenice Castle, Slovakia , May 20-24
    • MAJER, L.-STOPJAKOV, V.-VAVRINSKÝ, E.: Sensitive and Accurate Measurement Environment for Continuous Biomedical Monitoring using Microelectrodes, In: 6th International Conference on Measurement - MEASUREMENT 2007, Smolenice Castle, Slovakia, May 20-24, 2007, pp. 408-412.
    • (2007) Measurement 2007 , pp. 408-412
    • Majer, L.1    Stopjakov, V.2    Vavrinský, E.3
  • 11
    • 65749119300 scopus 로고    scopus 로고
    • AD5933 Datasheet
    • AD5933 Datasheet, http://www.analog.com/.
  • 12
    • 65749085800 scopus 로고    scopus 로고
    • ADuC832 Datasheet
    • ADuC832 Datasheet, http://www.analog.com/.
  • 14
    • 65749104724 scopus 로고    scopus 로고
    • nRF24E1 Datasheet
    • nRF24E1 Datasheet, http://www.nordicsemi.com/


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.