메뉴 건너뛰기




Volumn 24, Issue 2, 2009, Pages 806-813

A unified approach for the optimal PMU location for power system state estimation

Author keywords

Integer programming; Optimal location; PMUs; State estimation

Indexed keywords

BINARY DECISION; BINARY INTEGERS; BUS SYSTEMS; CONVENTIONAL MEASUREMENTS; CONVENTIONAL POWER; DECISION STRATEGY; MATHEMATICAL FORMULATION; NETWORK CONNECTIVITY; NETWORK TOPOLOGY; OPTIMAL LOCATION; OPTIMAL NUMBER; PHASOR MEASUREMENT UNIT; PMU PLACEMENT; PMUS; POWER SYSTEM STATE ESTIMATION; POWER SYSTEMS; SYSTEM MEASUREMENT; SYSTEM OBSERVABILITY; UNIFIED APPROACH;

EID: 65749094394     PISSN: 08858950     EISSN: None     Source Type: Journal    
DOI: 10.1109/TPWRS.2009.2016596     Document Type: Article
Times cited : (221)

References (12)
  • 1
    • 27844462056 scopus 로고    scopus 로고
    • Phasor measurement unit placement techniques for complete and incomplete observability
    • Oct
    • R. F. Nuqui and A. G. Phadke, "Phasor measurement unit placement techniques for complete and incomplete observability," IEEE Trans. Power Del., vol. 20, no. 4, pp. 2381-2388, Oct. 2005.
    • (2005) IEEE Trans. Power Del , vol.20 , Issue.4 , pp. 2381-2388
    • Nuqui, R.F.1    Phadke, A.G.2
  • 2
    • 0027573826 scopus 로고
    • Synchronized phasor measurements in power systems
    • Apr
    • A. G. Phadke, "Synchronized phasor measurements in power systems," IEEE Comput. Appl. Power, vol. 6, no. 2, pp. 10-15, Apr. 1993.
    • (1993) IEEE Comput. Appl. Power , vol.6 , Issue.2 , pp. 10-15
    • Phadke, A.G.1
  • 3
    • 84947668221 scopus 로고
    • State estimation with phasor measurements
    • Feb
    • A. G. Phadke, J. S. Thorp, and K. J. Karimi, "State estimation with phasor measurements," IEEE Trans. Power Syst., vol. 1, no. 1, pp. 233-241, Feb. 1986.
    • (1986) IEEE Trans. Power Syst , vol.1 , Issue.1 , pp. 233-241
    • Phadke, A.G.1    Thorp, J.S.2    Karimi, K.J.3
  • 4
    • 0022150236 scopus 로고
    • Real time voltage phasor measurements for static state estimation
    • Nov
    • A. G. Phadke, J. S. Thorp, and K. J. Karimi, "Real time voltage phasor measurements for static state estimation," IEEE Trans. Power App. Syst., vol. PAS-104, no. 11, pp. 3098-3107, Nov. 1985.
    • (1985) IEEE Trans. Power App. Syst , vol.PAS-104 , Issue.11 , pp. 3098-3107
    • Phadke, A.G.1    Thorp, J.S.2    Karimi, K.J.3
  • 5
    • 0027589817 scopus 로고
    • Power system observability with minimal phasor measurement placement
    • May
    • T. L. Baldwin, L. Mili, M. B. Boisen, and R. Adapa, "Power system observability with minimal phasor measurement placement," IEEE Trans. Power Syst., vol. 8, no. 2, pp. 701-715, May 1993.
    • (1993) IEEE Trans. Power Syst , vol.8 , Issue.2 , pp. 701-715
    • Baldwin, T.L.1    Mili, L.2    Boisen, M.B.3    Adapa, R.4
  • 6
    • 0011463350 scopus 로고
    • Minimal PMU Placement for Graph Observability,
    • M.S. thesis, Virginia Polytechnic Institute and State University, Blacksburg, VA
    • D. J. Brueni, "Minimal PMU Placement for Graph Observability," M.S. thesis, Virginia Polytechnic Institute and State University, Blacksburg, VA, 1993.
    • (1993)
    • Brueni, D.J.1
  • 7
    • 0038677145 scopus 로고    scopus 로고
    • Phasor measurement unit placement based on incomplete observability
    • Jul. 21-25
    • R. Nuqui and A. G. Phadke, "Phasor measurement unit placement based on incomplete observability," in Proc. IEEE Power Engineering Society Summer Meeting 2002, Jul. 21-25, 2002, vol. 2, pp. 888-893.
    • (2002) Proc. IEEE Power Engineering Society Summer Meeting 2002 , vol.2 , pp. 888-893
    • Nuqui, R.1    Phadke, A.G.2
  • 8
    • 0025563475 scopus 로고
    • Phasor measurement placement for voltage stability analysis of power systems
    • Honolulu, HI, Dec
    • L. Mili, T. Baldwin, and R. Adapa, "Phasor measurement placement for voltage stability analysis of power systems," in Proc. 29th Conf. Decision and Control, Honolulu, HI, Dec. 1990.
    • (1990) Proc. 29th Conf. Decision and Control
    • Mili, L.1    Baldwin, T.2    Adapa, R.3
  • 9
    • 33847645050 scopus 로고    scopus 로고
    • Placement of PMUs to enable bad data detection in state estimation
    • Nov
    • J. Chen and A. Abur, "Placement of PMUs to enable bad data detection in state estimation," IEEE Trans. Power Syst., vol. 21, no. 4, pp. 1608-1615, Nov. 2006.
    • (2006) IEEE Trans. Power Syst , vol.21 , Issue.4 , pp. 1608-1615
    • Chen, J.1    Abur, A.2
  • 10
    • 0037292302 scopus 로고    scopus 로고
    • Non-dominated sorting genetic algorithm for optimal phasor measurement placement
    • Feb
    • B. Milosevic and M. Begovic, "Non-dominated sorting genetic algorithm for optimal phasor measurement placement," IEEE Trans. Power Syst. vol. 18, no. 1, pp. 69-75, Feb. 2003.
    • (2003) IEEE Trans. Power Syst , vol.18 , Issue.1 , pp. 69-75
    • Milosevic, B.1    Begovic, M.2
  • 11
    • 15944400308 scopus 로고    scopus 로고
    • Observability analysis and measurement placement for systems with PMUs
    • Oct. 10-13
    • B. Xu and A. Abur, "Observability analysis and measurement placement for systems with PMUs," in Proc. 2004 IEEE PES Conf. and Expo., Oct. 10-13, 2004, vol. 2, pp. 943-946.
    • (2004) Proc. 2004 IEEE PES Conf. and Expo , vol.2 , pp. 943-946
    • Xu, B.1    Abur, A.2
  • 12
    • 71849091088 scopus 로고    scopus 로고
    • Optimal placement and utilization of phasor measurements for state estimation
    • B. Xu, Y. J. Yoon, and A. Abur, "Optimal placement and utilization of phasor measurements for state estimation," PSERC Pub. 05-20, 2005.
    • (2005) PSERC Pub. 05-20
    • Xu, B.1    Yoon, Y.J.2    Abur, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.