메뉴 건너뛰기




Volumn 267, Issue 5-8, 2009, Pages 757-762

Differences in wear between load and displacement control tested total knee replacements

Author keywords

Control mode; Implant wear; Simulator testing; Total knee arthroplasty; UHMWPE

Indexed keywords

CONTROL MODE; IMPLANT WEAR; SIMULATOR TESTING; TOTAL KNEE ARTHROPLASTY; UHMWPE;

EID: 65749094059     PISSN: 00431648     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.wear.2009.01.028     Document Type: Article
Times cited : (22)

References (15)
  • 1
    • 34447308658 scopus 로고    scopus 로고
    • The future burden of hip and knee revisions: US projections from 2005 to 2030
    • Chicago, IL, USA
    • Kurtz S., Lau E., Mowat F., Ong K., and Halpern M. The future burden of hip and knee revisions: US projections from 2005 to 2030. AAOS, 73rd Annual Meeting. Chicago, IL, USA (2006)
    • (2006) AAOS, 73rd Annual Meeting
    • Kurtz, S.1    Lau, E.2    Mowat, F.3    Ong, K.4    Halpern, M.5
  • 2
    • 0034762231 scopus 로고    scopus 로고
    • The swedish knee arthroplasty register 1975-1997: an update with special emphasis on 41,223 knees operated on in 1988-1997
    • Robertsson O., Knutson K., Lewold S., and Lidgren L. The swedish knee arthroplasty register 1975-1997: an update with special emphasis on 41,223 knees operated on in 1988-1997. Acta Orthop. Scand. 72 5 (2001) 503-513
    • (2001) Acta Orthop. Scand. , vol.72 , Issue.5 , pp. 503-513
    • Robertsson, O.1    Knutson, K.2    Lewold, S.3    Lidgren, L.4
  • 3
    • 10444259142 scopus 로고    scopus 로고
    • Implants for surgery-wear of total knee-joint prostheses. Part 1. Loading and displacement parameters for wear-testing machines with load control and corresponding environmental conditions for test,
    • ISO 14243-1
    • ISO 14243-1, Implants for surgery-wear of total knee-joint prostheses. Part 1. Loading and displacement parameters for wear-testing machines with load control and corresponding environmental conditions for test, 2002.
    • (2002)
  • 4
    • 0006581415 scopus 로고    scopus 로고
    • Implants for surgery-wear of total knee joint prosthesis. Part 3. Loading and displacement parameters for wear testing machines with displacement control and corresponding environmental conditions for tests,
    • ISO 14243-2
    • ISO 14243-2, Implants for surgery-wear of total knee joint prosthesis. Part 3. Loading and displacement parameters for wear testing machines with displacement control and corresponding environmental conditions for tests, 2001.
    • (2001)
  • 7
    • 24844457156 scopus 로고    scopus 로고
    • Finite element analysis of TKR captures device-dependent kinematics and wear potential
    • Dallas, USA
    • Rawlinson J., Furman B., Li S., and Bartel D. Finite element analysis of TKR captures device-dependent kinematics and wear potential. ORS, 48th Annual Meeting. Dallas, USA (2002)
    • (2002) ORS, 48th Annual Meeting
    • Rawlinson, J.1    Furman, B.2    Li, S.3    Bartel, D.4
  • 8
    • 0032170251 scopus 로고    scopus 로고
    • Computer model to predict subsurface damage in tibial inserts of total knees
    • Sathasivam S., and Walker P.S. Computer model to predict subsurface damage in tibial inserts of total knees. J. Orthop. Res. 16 5 (1998) 564-571
    • (1998) J. Orthop. Res. , vol.16 , Issue.5 , pp. 564-571
    • Sathasivam, S.1    Walker, P.S.2
  • 9
    • 0038721520 scopus 로고    scopus 로고
    • Analysis and recommendations for the optimum spring configurations for soft tissue restraint in force-control knee simulator testing
    • Dallas, USA
    • Haider H., and Walker P.S. Analysis and recommendations for the optimum spring configurations for soft tissue restraint in force-control knee simulator testing. ORS, 48th Annual Meeting. Dallas, USA (2002)
    • (2002) ORS, 48th Annual Meeting
    • Haider, H.1    Walker, P.S.2
  • 10
    • 34248168269 scopus 로고    scopus 로고
    • Implants for surgery-wear of total knee-joint prostheses. Part 2. Methods of measurement,
    • ISO 14243-2
    • ISO 14243-2, Implants for surgery-wear of total knee-joint prostheses. Part 2. Methods of measurement, 2000.
    • (2000)
  • 11
    • 0035680487 scopus 로고    scopus 로고
    • Comparison of wear in a total knee replacement under different kinematic conditions
    • Barnett P.I., Fisher J., Auger D.D., Stone M.H., and Ingham E. Comparison of wear in a total knee replacement under different kinematic conditions. J. Mater. Sci. Mater. Med. 12 10-12 (2001) 1039-1042
    • (2001) J. Mater. Sci. Mater. Med. , vol.12 , Issue.10-12 , pp. 1039-1042
    • Barnett, P.I.1    Fisher, J.2    Auger, D.D.3    Stone, M.H.4    Ingham, E.5
  • 14
    • 0036050575 scopus 로고    scopus 로고
    • Effect of stair descent loading on ultra-high molecular weight polyethylene wear in a force-controlled knee simulator
    • Benson L.C., DesJardins J.D., Harman M.K., and LaBerge M. Effect of stair descent loading on ultra-high molecular weight polyethylene wear in a force-controlled knee simulator. Proc. Inst. Mech. Eng. [H] 216 (2002) 409-418
    • (2002) Proc. Inst. Mech. Eng. [H] , vol.216 , pp. 409-418
    • Benson, L.C.1    DesJardins, J.D.2    Harman, M.K.3    LaBerge, M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.