메뉴 건너뛰기




Volumn 93, Issue 1, 2009, Pages 139-149

Frame-based stereotaxy in a frameless era: Current capabilities, relative role, and the positive- and negative predictive values of blood through the needle

Author keywords

Biopsy, needle; Brain neoplasm; Diagnosis; Diagnosis, differential; Neuronavigation; Stereotaxic techniques

Indexed keywords

ADOLESCENT; ADULT; AGED; ARTICLE; BRAIN CANCER; BRAIN CIRCULUS ARTERIOSUS; BRAIN VEIN; CEREBELLUM TENTORIUM; CHILD; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED STUDY; CRANIOTOMY; DIAGNOSTIC ACCURACY; DIAGNOSTIC VALUE; FEMALE; FRAMELESS STEREOTACTIC PROCEDURE; GLIOBLASTOMA; HISTOPATHOLOGY; HUMAN; INTERMETHOD COMPARISON; MAJOR CLINICAL STUDY; MALE; MORTALITY; MULTIPLE SCLEROSIS; NEEDLE BIOPSY; NEUROIMAGING; NEUROLOGIC DISEASE; NEUROSURGERY; NUCLEAR MAGNETIC RESONANCE IMAGING; OLIGODENDROGLIOMA; PATIENT SAFETY; PINEAL BODY; PREDICTION; PRESCHOOL CHILD; PRIMARY CENTRAL NERVOUS SYSTEM LYMPHOMA; RISK ASSESSMENT; SCHOOL CHILD; STEREOTACTIC BIOPSY; SUPRASYLVIAN GYRUS; TUMOR LOCALIZATION; TUMOR VOLUME;

EID: 65649146502     PISSN: 0167594X     EISSN: 15737373     Source Type: Journal    
DOI: 10.1007/s11060-009-9871-y     Document Type: Article
Times cited : (89)

References (33)
  • 2
    • 0019726453 scopus 로고
    • Stereotactic biopsy of intracranial space occupying lesions
    • doi: 10.1007/BF01664839
    • Edner G (1981) Stereotactic biopsy of intracranial space occupying lesions. Acta Neurochir (Wien) 57:213-234. doi: 10.1007/BF01664839
    • (1981) Acta Neurochir (Wien) , vol.57 , pp. 213-234
    • Edner, G.1
  • 3
    • 0019802278 scopus 로고
    • Stereotactic biopsy of brain lesions visualized with computed tomography
    • doi: 10.1159/000101637
    • Lobato RD, Rivas JJ, Cabello A, Roger R (1982) Stereotactic biopsy of brain lesions visualized with computed tomography. Appl Neurophysiol 45:426-430. doi: 10.1159/000101637
    • (1982) Appl Neurophysiol , vol.45 , pp. 426-430
    • Lobato, R.D.1    Rivas, J.J.2    Cabello, A.3    Roger, R.4
  • 4
    • 0023212697 scopus 로고
    • Computed imaging stereotaxy: Experience and perspective related to 500 procedures applied to brain masses
    • doi: 10.1097/00006123-198706000-00019
    • Apuzzo ML, Chandrasoma PT, Cohen D, Zee CS, Zelman V (1987) Computed imaging stereotaxy: Experience and perspective related to 500 procedures applied to brain masses. Neurosurgery 20:930-937. doi: 10.1097/ 00006123-198706000-00019
    • (1987) Neurosurgery , vol.20 , pp. 930-937
    • Apuzzo, M.L.1    Chandrasoma, P.T.2    Cohen, D.3    Zee, C.S.4    Zelman, V.5
  • 5
    • 0020694242 scopus 로고
    • Computed tomographic guidance stereotaxis in the management of intracranial mass lesions
    • doi: 10.1097/00006123-198303000-00005
    • Apuzzo ML, Sabshin JK (1983) Computed tomographic guidance stereotaxis in the management of intracranial mass lesions. Neurosurgery 12:277-285. doi: 10.1097/00006123-198303000-00005
    • (1983) Neurosurgery , vol.12 , pp. 277-285
    • Apuzzo, M.L.1    Sabshin, J.K.2
  • 6
    • 0021185714 scopus 로고
    • Stereotactic exploration of the brain in the era of computed tomography
    • doi: 10.1016/0090-3019(84)90003-X
    • Lunsford LD, Martinez AJ (1984) Stereotactic exploration of the brain in the era of computed tomography. Surg Neurol 22:222-230. doi: 10.1016/ 0090-3019(84)90003-X
    • (1984) Surg Neurol , vol.22 , pp. 222-230
    • Lunsford, L.D.1    Martinez, A.J.2
  • 7
    • 0022334240 scopus 로고
    • CT stereotactic biopsy for optimizing the therapy of intracranial processes
    • Mundinger F (1985) CT stereotactic biopsy for optimizing the therapy of intracranial processes. Acta Neurochir Suppl (Wien) 35:70-74
    • (1985) Acta Neurochir Suppl (Wien) , vol.35 , pp. 70-74
    • Mundinger, F.1
  • 8
    • 0036107546 scopus 로고    scopus 로고
    • The advantages of frameless stereotactic biopsy over frame-based biopsy
    • doi: 10.1080/02688690220131705
    • Dorward NL, Paleologos TS, Alberti O, Thomas DG (2002) The advantages of frameless stereotactic biopsy over frame-based biopsy. Br J Neurosurg 16:110-118. doi: 10.1080/02688690220131705
    • (2002) Br J Neurosurg , vol.16 , pp. 110-118
    • Dorward, N.L.1    Paleologos, T.S.2    Alberti, O.3    Thomas, D.G.4
  • 9
    • 0034806295 scopus 로고    scopus 로고
    • Clinical validation of true frameless stereotactic biopsy: Analysis of the first 125 consecutive cases
    • discussion 835-837
    • Paleologos TS, Dorward NL, Wadley JP, Thomas DG (2001) Clinical validation of true frameless stereotactic biopsy: Analysis of the first 125 consecutive cases. Neurosurgery 49:830-835 discussion 835-837
    • (2001) Neurosurgery , vol.49 , pp. 830-835
    • Paleologos, T.S.1    Dorward, N.L.2    Wadley, J.P.3    Thomas, D.G.4
  • 10
    • 22144436988 scopus 로고    scopus 로고
    • Frame-based stereotactic biopsy remains an important diagnostic tool with distinct advantages over frameless stereotactic biopsy
    • doi: 10.1007/s11060-004-4208-3
    • Smith JS, Quinones-Hinojosa A, Barbaro NM, McDermott MW (2005) Frame-based stereotactic biopsy remains an important diagnostic tool with distinct advantages over frameless stereotactic biopsy. J Neurooncol 73:173-179. doi: 10.1007/s11060-004-4208-3
    • (2005) J Neurooncol , vol.73 , pp. 173-179
    • Smith, J.S.1    Quinones-Hinojosa, A.2    Barbaro, N.M.3    McDermott, M.W.4
  • 11
    • 33644516000 scopus 로고    scopus 로고
    • Frameless image-guided stereotactic brain biopsy procedure: Diagnostic yield, surgical morbidity, and comparison with the frame-based technique
    • doi: 10.3171/jns.2006.104.2.233
    • Woodworth GF, McGirt MJ, Samdani A, Garonzik I, Olivi A, Weingart JD (2006) Frameless image-guided stereotactic brain biopsy procedure: diagnostic yield, surgical morbidity, and comparison with the frame-based technique. J Neurosurg 104:233-237. doi: 10.3171/ jns.2006.104.2.233
    • (2006) J Neurosurg , vol.104 , pp. 233-237
    • Woodworth, G.F.1    McGirt, M.J.2    Samdani, A.3    Garonzik, I.4    Olivi, A.5    Weingart, J.D.6
  • 13
    • 0025719784 scopus 로고
    • Neuroimaging of acoustic nerve sheath tumors after stereotaxic radiosurgery
    • Linskey ME, Lunsford LD, Flickinger JC (1991) Neuroimaging of acoustic nerve sheath tumors after stereotaxic radiosurgery. AJNR Am J Neuroradiol 12:1165-1175
    • (1991) AJNR Am J Neuroradiol , vol.12 , pp. 1165-1175
    • Linskey, M.E.1    Lunsford, L.D.2    Flickinger, J.C.3
  • 15
    • 0028222832 scopus 로고
    • Results of 200 intracranial stereotactic biopsies
    • doi: 10.1007/BF00309989
    • Grunert P, Ungersbock K, Bohl J, Kitz K, Hopf N (1994) Results of 200 intracranial stereotactic biopsies. Neurosurg Rev 17:59-66. doi: 10.1007/ BF00309989
    • (1994) Neurosurg Rev , vol.17 , pp. 59-66
    • Grunert, P.1    Ungersbock, K.2    Bohl, J.3    Kitz, K.4    Hopf, N.5
  • 16
    • 19544367976 scopus 로고    scopus 로고
    • Accuracy of frameless and frame-based image-guided stereotactic brain biopsy in the diagnosis of glioma: Comparison of biopsy and open resection specimen
    • doi: 10.1179/016164105X40057
    • Woodworth G, McGirt MJ, Samdani A, Garonzik I, Olivi A, Weingart JD (2005) Accuracy of frameless and frame-based image-guided stereotactic brain biopsy in the diagnosis of glioma: Comparison of biopsy and open resection specimen. Neurol Res 27:358-362. doi: 10.1179/016164105X40057
    • (2005) Neurol Res , vol.27 , pp. 358-362
    • Woodworth, G.1    McGirt, M.J.2    Samdani, A.3    Garonzik, I.4    Olivi, A.5    Weingart, J.D.6
  • 17
    • 0035692524 scopus 로고    scopus 로고
    • Stereotactic biopsy aided by a computer graphics workstation: Experience with 200 consecutive cases
    • discussion 371-362
    • Ulm AJ, Bova FJ, Friedman WA (2001) Stereotactic biopsy aided by a computer graphics workstation: Experience with 200 consecutive cases. Surg Neurol 56:366-371 discussion 371-362
    • (2001) Surg Neurol , vol.56 , pp. 366-371
    • Ulm, A.J.1    Bova, F.J.2    Friedman, W.A.3
  • 18
    • 0034867349 scopus 로고    scopus 로고
    • Comprehensive assessment of hemorrhage risks and outcomes after stereotactic brain biopsy
    • Field M, Witham TF, Flickinger JC, Kondziolka D, Lunsford LD (2001) Comprehensive assessment of hemorrhage risks and outcomes after stereotactic brain biopsy. J Neurosurg 94:545-551
    • (2001) J Neurosurg , vol.94 , pp. 545-551
    • Field, M.1    Witham, T.F.2    Flickinger, J.C.3    Kondziolka, D.4    Lunsford, L.D.5
  • 19
    • 0029808132 scopus 로고    scopus 로고
    • Pineal region tumors and the role of stereotactic biopsy: Review of the mortality, morbidity, and diagnostic rates in 370 cases
    • discussion 912-904
    • Regis J, Bouillot P, Rouby-Volot F, Figarella-Branger D, Dufour H, Peragut JC (1996) Pineal region tumors and the role of stereotactic biopsy: Review of the mortality, morbidity, and diagnostic rates in 370 cases. Neurosurgery 39:907-912 discussion 912-904
    • (1996) Neurosurgery , vol.39 , pp. 907-912
    • Regis, J.1    Bouillot, P.2    Rouby-Volot, F.3    Figarella-Branger, D.4    Dufour, H.5    Peragut, J.C.6
  • 20
    • 0027935823 scopus 로고
    • Complications of CT-guided stereotactic biopsy of intra-axial brain lesions
    • Bernstein M, Parrent AG (1994) Complications of CT-guided stereotactic biopsy of intra-axial brain lesions. J Neurosurg 81:165-168
    • (1994) J Neurosurg , vol.81 , pp. 165-168
    • Bernstein, M.1    Parrent, A.G.2
  • 21
    • 1542314326 scopus 로고    scopus 로고
    • Stereotactic biopsy for multifocal, diffuse, and deep-seated brain tumors using Leksell's system
    • doi: 10.1016/j.jocn.2003.03.004
    • Yamada K, Goto S, Kochi M, Ushio Y (2004) Stereotactic biopsy for multifocal, diffuse, and deep-seated brain tumors using Leksell's system. J Clin Neurosci 11:263-267. doi: 10.1016/j.jocn.2003.03.004
    • (2004) J Clin Neurosci , vol.11 , pp. 263-267
    • Yamada, K.1    Goto, S.2    Kochi, M.3    Ushio, Y.4
  • 22
    • 0028506334 scopus 로고
    • Importance of image-guided stereotactic biopsy to confirm diagnosis in an oncological setting
    • doi: 10.1007/BF02303807
    • Arbit E, Galicich JH (1994) Importance of image-guided stereotactic biopsy to confirm diagnosis in an oncological setting. Ann Surg Oncol 1:368-372. doi: 10.1007/BF02303807
    • (1994) Ann Surg Oncol , vol.1 , pp. 368-372
    • Arbit, E.1    Galicich, J.H.2
  • 24
    • 33748478560 scopus 로고    scopus 로고
    • Stereotactic brain biopsy: An audit of sampling reliability in a clinical case series
    • doi: 10.1080/02688690600875507
    • Shastri-Hurst N, Tsegaye M, Robson DK, Lowe JS, Macarthur DC (2006) Stereotactic brain biopsy: An audit of sampling reliability in a clinical case series. Br J Neurosurg 20:222-226. doi: 10.1080/ 02688690600875507
    • (2006) Br J Neurosurg , vol.20 , pp. 222-226
    • Shastri-Hurst, N.1    Tsegaye, M.2    Robson, D.K.3    Lowe, J.S.4    Macarthur, D.C.5
  • 25
    • 0031859190 scopus 로고    scopus 로고
    • Incidence of silent hemorrhage and delayed deterioration after stereotactic brain biopsy
    • Kulkarni AV, Guha A, Lozano A, Bernstein M (1998) Incidence of silent hemorrhage and delayed deterioration after stereotactic brain biopsy. J Neurosurg 89:31-35
    • (1998) J Neurosurg , vol.89 , pp. 31-35
    • Kulkarni, A.V.1    Guha, A.2    Lozano, A.3    Bernstein, M.4
  • 26
    • 33745803043 scopus 로고    scopus 로고
    • Quantification of true in vivo application accuracy in cranial image-guided surgery: Influence of mode of patient registration
    • discussion ONS146-156
    • Mascott CR, Sol JC, Bousquet P, Lagarrigue J, Lazorthes Y, Lauwers-Cances V (2006) Quantification of true in vivo application accuracy in cranial image-guided surgery: Influence of mode of patient registration. Neurosurgery 59:ONS146-ONS156 discussion ONS146-156
    • (2006) Neurosurgery , vol.59
    • Mascott, C.R.1    Sol, J.C.2    Bousquet, P.3    Lagarrigue, J.4    Lazorthes, Y.5    Lauwers-Cances, V.6
  • 27
    • 0032902417 scopus 로고    scopus 로고
    • Accuracy of true frameless stereotaxy: In vivo measurement and laboratory phantom studies. Technical note
    • Dorward NL, Alberti O, Palmer JD, Kitchen ND, Thomas DG (1999) Accuracy of true frameless stereotaxy: In vivo measurement and laboratory phantom studies. Technical note. J Neurosurg 90:160-168
    • (1999) J Neurosurg , vol.90 , pp. 160-168
    • Dorward, N.L.1    Alberti, O.2    Palmer, J.D.3    Kitchen, N.D.4    Thomas, D.G.5
  • 28
    • 30944453864 scopus 로고    scopus 로고
    • Assessment of image guided accuracy in a skull model: Comparison of frameless stereotaxy techniques vs. frame-based localization
    • doi: 10.1007/s11060-005-2915-z
    • Quinones-Hinojosa A, Ware ML, Sanai N, McDermott MW (2006) Assessment of image guided accuracy in a skull model: Comparison of frameless stereotaxy techniques vs. frame-based localization. J Neurooncol 76:65-70. doi: 10.1007/s11060-005-2915-z
    • (2006) J Neurooncol , vol.76 , pp. 65-70
    • Quinones-Hinojosa, A.1    Ware, M.L.2    Sanai, N.3    McDermott, M.W.4
  • 29
    • 0030030322 scopus 로고    scopus 로고
    • A phantom study to assess the accuracy of stereotactic localization, using T1-weighted magnetic resonance imaging with the Leksell stereotactic system
    • discussion 176-178
    • Walton L, Hampshire A, Forster DM, Kemeny AA (1996) A phantom study to assess the accuracy of stereotactic localization, using T1-weighted magnetic resonance imaging with the Leksell stereotactic system. Neurosurgery 38:170-176 discussion 176-178
    • (1996) Neurosurgery , vol.38 , pp. 170-176
    • Walton, L.1    Hampshire, A.2    Forster, D.M.3    Kemeny, A.A.4
  • 30
    • 0028001440 scopus 로고
    • The application accuracy of stereotactic frames
    • discussion 694-685
    • Maciunas RJ, Galloway RL Jr, Latimer JW (1994) The application accuracy of stereotactic frames. Neurosurgery 35:682-694 discussion 694-685
    • (1994) Neurosurgery , vol.35 , pp. 682-694
    • Maciunas, R.J.1    Galloway Jr., R.L.2    Latimer, J.W.3
  • 31
    • 0036323903 scopus 로고    scopus 로고
    • Implantation of deep brain stimulators into the subthalamic nucleus: Technical approach and magnetic resonance imaging-verified lead locations
    • Starr PA, Christine CW, Theodosopoulos PV, Lindsey N, Byrd D, Mosley A, Marks WJ Jr (2002) Implantation of deep brain stimulators into the subthalamic nucleus: Technical approach and magnetic resonance imaging-verified lead locations. J Neurosurg 97:370-387
    • (2002) J Neurosurg , vol.97 , pp. 370-387
    • Starr, P.A.1    Christine, C.W.2    Theodosopoulos, P.V.3    Lindsey, N.4    Byrd, D.5    Mosley, A.6    Marks Jr., W.J.7
  • 32
    • 0031665414 scopus 로고    scopus 로고
    • Accuracy of registration methods in frameless stereotaxis
    • Helm PA, Eckel TS (1998) Accuracy of registration methods in frameless stereotaxis. Comput Aided Surg 3:51-56
    • (1998) Comput Aided Surg , vol.3 , pp. 51-56
    • Helm, P.A.1    Eckel, T.S.2
  • 33
    • 0036216774 scopus 로고    scopus 로고
    • Stereotactic biopsies guided by an optical navigation system: Technique and clinical experience
    • doi: 10.1055/s-2002-23576
    • Grunert P, Espinosa J, Busert C, Gunthner M, Filippi R, Farag S, Hopf N (2002) Stereotactic biopsies guided by an optical navigation system: technique and clinical experience. Minim Invasive Neurosurg 45:11-15. doi: 10.1055/s-2002-23576
    • (2002) Minim Invasive Neurosurg , vol.45 , pp. 11-15
    • Grunert, P.1    Espinosa, J.2    Busert, C.3    Gunthner, M.4    Filippi, R.5    Farag, S.6    Hopf, N.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.