메뉴 건너뛰기




Volumn 17, Issue 1, 2009, Pages 29-35

Use of the AngioSculpt Scoring Balloon for infrapopliteal lesions in patients with critical limb ischemia: 1-year outcome

Author keywords

Balloon; Critical limb ischemia; Infrapopliteal; Limb salvage; Scoring

Indexed keywords

ACETYLSALICYLIC ACID; CLOPIDOGREL; HEPARIN; LOW MOLECULAR WEIGHT HEPARIN; ALLOY; NITINOL;

EID: 65549170480     PISSN: 17085381     EISSN: None     Source Type: Journal    
DOI: 10.2310/6670.2009.00001     Document Type: Article
Times cited : (41)

References (28)
  • 1
    • 12144256606 scopus 로고    scopus 로고
    • Early results with infrainguinal cutting balloon angioplasty limits distal dissection
    • Rabbi JF, Kiran RP, Gersten G, et al. Early results with infrainguinal cutting balloon angioplasty limits distal dissection. Ann Vasc Surg 2004;18:640-3.
    • (2004) Ann Vasc Surg , vol.18 , pp. 640-643
    • Rabbi, J.F.1    Kiran, R.P.2    Gersten, G.3
  • 2
    • 1642505682 scopus 로고    scopus 로고
    • Early outcome of "cutting" balloon angioplasty for infrainguinal vein graft stenosis
    • Kasirajan K, Schneider PA. Early outcome of "cutting" balloon angioplasty for infrainguinal vein graft stenosis. J Vasc Surg 2004; 39:702-8.
    • (2004) J Vasc Surg , vol.39 , pp. 702-708
    • Kasirajan, K.1    Schneider, P.A.2
  • 3
    • 10644222795 scopus 로고    scopus 로고
    • Primary stent-supported angioplasty for treatment of below-knee critical limb ischemia and severe claudication: Early and one-year outcomes
    • Feiring AJ, Wesolowski AA, Lade S. Primary stent-supported angioplasty for treatment of below-knee critical limb ischemia and severe claudication: early and one-year outcomes. J Am Coll Cardiol 2004;44:2307-14.
    • (2004) J Am Coll Cardiol , vol.44 , pp. 2307-2314
    • Feiring, A.J.1    Wesolowski, A.A.2    Lade, S.3
  • 4
    • 0842289289 scopus 로고    scopus 로고
    • A new look at infrainguinal bypass surgery: Traditional reporting standards systematically underestimate the expenditure of effort required to attain limb salvage
    • Goshima KR, Mills JR, Hughes JD. A new look at infrainguinal bypass surgery: traditional reporting standards systematically underestimate the expenditure of effort required to attain limb salvage. J Vasc Surg 2004;39:330.
    • (2004) J Vasc Surg , vol.39 , pp. 330
    • Goshima, K.R.1    Mills, J.R.2    Hughes, J.D.3
  • 5
    • 0029904591 scopus 로고    scopus 로고
    • Rehabilitation of the older lower limb amputee: A brief review
    • Cutson TM, Bongiorni DR. Rehabilitation of the older lower limb amputee: a brief review. J Am Geriatr Soc 1996;44:1388-93.
    • (1996) J Am Geriatr Soc , vol.44 , pp. 1388-1393
    • Cutson, T.M.1    Bongiorni, D.R.2
  • 6
    • 28244470064 scopus 로고    scopus 로고
    • The BASIL Trial Participants. Bypass versus Angioplasty in Severe Ischaemia of the Leg (BASIL): Multicentre, randomized controlled trial
    • The BASIL Trial Participants. Bypass versus Angioplasty in Severe Ischaemia of the Leg (BASIL): multicentre, randomized controlled trial. Lancet 2005;366:1925-34.
    • (2005) Lancet , vol.366 , pp. 1925-1934
  • 7
    • 0033800814 scopus 로고    scopus 로고
    • Prospective trial of infrapopliteal artery balloon angioplasty for critical limb ischemia: Angiographic and clinical results
    • Soder HK, Manninen HI, Jaakkola P, et al. Prospective trial of infrapopliteal artery balloon angioplasty for critical limb ischemia: angiographic and clinical results. J Vasc Interv Radiol 2000;11: 1021-31.
    • (2000) J Vasc Interv Radiol , vol.11 , pp. 1021-1031
    • Soder, H.K.1    Manninen, H.I.2    Jaakkola, P.3
  • 8
    • 33745889637 scopus 로고    scopus 로고
    • Endovascular therapy as the primary approach for limb salvage in patients with critical limb ischemia: Experience with 443 infrapopliteal procedures
    • Bosiers M, Hart JP, Deloose K, et al. Endovascular therapy as the primary approach for limb salvage in patients with critical limb ischemia: experience with 443 infrapopliteal procedures. Vascular 2006;14:63-9.
    • (2006) Vascular , vol.14 , pp. 63-69
    • Bosiers, M.1    Hart, J.P.2    Deloose, K.3
  • 9
    • 0032581031 scopus 로고    scopus 로고
    • Lower expression of neutrophil adhesion molecule indicates less vessel wall injury and might explain lower restenosis rate after cutting balloon angioplasty
    • Inoue T, Sakai Y, Hoshi K, et al. Lower expression of neutrophil adhesion molecule indicates less vessel wall injury and might explain lower restenosis rate after cutting balloon angioplasty. Circulation 1998;97:2511-8.
    • (1998) Circulation , vol.97 , pp. 2511-2518
    • Inoue, T.1    Sakai, Y.2    Hoshi, K.3
  • 10
    • 0034764640 scopus 로고    scopus 로고
    • Stand-alone cutting balloon angioplasty for the treatment of stent-related restenosis: Acute results and 3- to 6-month angiographic recurrent restenosis rates
    • Miyamato T, Araki T, Hiroe M, et al. Stand-alone cutting balloon angioplasty for the treatment of stent-related restenosis: acute results and 3- to 6-month angiographic recurrent restenosis rates. Catheter Cardiovasc Intervent 2001;54:301-8.
    • (2001) Catheter Cardiovasc Intervent , vol.54 , pp. 301-308
    • Miyamato, T.1    Araki, T.2    Hiroe, M.3
  • 11
    • 12144287459 scopus 로고    scopus 로고
    • Cutting balloon versus conventional balloon angioplasty for the treatment of in-stent restenosis: Results of the restenosis cutting balloon evaluation trial (RESCUT)
    • Albiero R, Silber S, Di Mario C, et al. Cutting balloon versus conventional balloon angioplasty for the treatment of in-stent restenosis: results of the restenosis cutting balloon evaluation trial (RESCUT). J Am Coll Cardiol 2004;43:943-9.
    • (2004) J Am Coll Cardiol , vol.43 , pp. 943-949
    • Albiero, R.1    Silber, S.2    Di Mario, C.3
  • 12
    • 0034857558 scopus 로고    scopus 로고
    • Cutting balloon angioplasty for the treatment of in-stent restenosis: A matched comparison with rotational atherectomy, additional stent implantation and balloon angioplasty
    • Adamian M, Colombo A, Briguori C, et al. Cutting balloon angioplasty for the treatment of in-stent restenosis: a matched comparison with rotational atherectomy, additional stent implantation and balloon angioplasty. J Am Coll Cardiol 2001;38: 672-9.
    • (2001) J Am Coll Cardiol , vol.38 , pp. 672-679
    • Adamian, M.1    Colombo, A.2    Briguori, C.3
  • 13
    • 0035374592 scopus 로고    scopus 로고
    • Efficacy of cutting balloon angioplasty for in-stent restenosis: An intravascular ultrasound evaluation
    • Muramatsu T, Tsukahara R, Ho M, et al. Efficacy of cutting balloon angioplasty for in-stent restenosis: an intravascular ultrasound evaluation. J Invas Cardiol 2001;13:439-44.
    • (2001) J Invas Cardiol , vol.13 , pp. 439-444
    • Muramatsu, T.1    Tsukahara, R.2    Ho, M.3
  • 14
    • 0037112042 scopus 로고    scopus 로고
    • Cutting balloon angioplasty for the prevention of restenosis: Results of the cutting balloon global randomized trial
    • Mauri L, Bonan R, Weiner BH, et al. Cutting balloon angioplasty for the prevention of restenosis: results of the cutting balloon global randomized trial. Am J Cardiol 2002;90:1079-83.
    • (2002) Am J Cardiol , vol.90 , pp. 1079-1083
    • Mauri, L.1    Bonan, R.2    Weiner, B.H.3
  • 15
    • 0036897108 scopus 로고    scopus 로고
    • Delayed appearance of coronary artery perforation following cutting balloon angioplasty
    • Maruo T, Yasuda S, Miyazaki S. Delayed appearance of coronary artery perforation following cutting balloon angioplasty. Catheter Cardiovasc Interv 2002;57:529-31.
    • (2002) Catheter Cardiovasc Interv , vol.57 , pp. 529-531
    • Maruo, T.1    Yasuda, S.2    Miyazaki, S.3
  • 16
    • 25444533107 scopus 로고    scopus 로고
    • Cutting-balloon-associated vascular rupture after failed standard balloon angioplasty
    • Chakraverty S, Meier MA, Aarts JC, et al. Cutting-balloon-associated vascular rupture after failed standard balloon angioplasty. Cardiovasc Intervent Radiol 2005;28:661-4.
    • (2005) Cardiovasc Intervent Radiol , vol.28 , pp. 661-664
    • Chakraverty, S.1    Meier, M.A.2    Aarts, J.C.3
  • 17
    • 10344249385 scopus 로고    scopus 로고
    • Cutting balloon angioplasty for resistant venous stenoses of Brescia-Cimino fistulas
    • Song HH, Kim KT, Chung SK, et al. Cutting balloon angioplasty for resistant venous stenoses of Brescia-Cimino fistulas. J Vasc Interv Radiol 2004;15:1463-7.
    • (2004) J Vasc Interv Radiol , vol.15 , pp. 1463-1467
    • Song, H.H.1    Kim, K.T.2    Chung, S.K.3
  • 18
    • 21144456453 scopus 로고    scopus 로고
    • Rupture of the renal artery after cutting balloon angioplasty in a young woman with fibromuscular dysplasia
    • Oguzkurt L, Tercan F, Gulcan O, Turkoz R. Rupture of the renal artery after cutting balloon angioplasty in a young woman with fibromuscular dysplasia. Cardiovasc Intervent Radiol 2005;28:360-3.
    • (2005) Cardiovasc Intervent Radiol , vol.28 , pp. 360-363
    • Oguzkurt, L.1    Tercan, F.2    Gulcan, O.3    Turkoz, R.4
  • 19
    • 33745845449 scopus 로고    scopus 로고
    • Cutting balloons for the treatment of vascular stenoses
    • Tsetis D, Morgan R, Belli A-M. Cutting balloons for the treatment of vascular stenoses. Eur Radiol 2006;16:1675-83.
    • (2006) Eur Radiol , vol.16 , pp. 1675-1683
    • Tsetis, D.1    Morgan, R.2    Belli, A.-M.3
  • 20
    • 0346732108 scopus 로고    scopus 로고
    • Cutting balloon angioplasty of the popliteal and infrapopliteal vessels for symptomatic limb ischemia
    • Ansel GM, Sample NS, Botti CF, et al. Cutting balloon angioplasty of the popliteal and infrapopliteal vessels for symptomatic limb ischemia. Catheter Cardiovasc Interv 2004;61:1-4.
    • (2004) Catheter Cardiovasc Interv , vol.61 , pp. 1-4
    • Ansel, G.M.1    Sample, N.S.2    Botti, C.F.3
  • 21
    • 38049013149 scopus 로고    scopus 로고
    • Final results from the U.S. multi-center trial of the AngioSculpt scoring balloon catheter for the treatment of complex coronary artery lesions [abstract]
    • Mooney M, Teirstein P, Moses J, et al. Final results from the U.S. multi-center trial of the AngioSculpt scoring balloon catheter for the treatment of complex coronary artery lesions [abstract]. Am J Cardiol 2006;98:121M.
    • (2006) Am J Cardiol , vol.98
    • Mooney, M.1    Teirstein, P.2    Moses, J.3
  • 22
    • 24044486265 scopus 로고    scopus 로고
    • Cutting balloon: Review on principles and background of use in peripheral arteries
    • Cejna M. Cutting balloon: review on principles and background of use in peripheral arteries. Cardiovasc Intervent Radiol 2005;28: 400-8.
    • (2005) Cardiovasc Intervent Radiol , vol.28 , pp. 400-408
    • Cejna, M.1
  • 23
    • 35648940903 scopus 로고    scopus 로고
    • Cutting balloon angioplasty versus standard balloon angioplasty for failing infra-inguinal vein grafts: Comparative study of short- and mid-term primary patency rates
    • DOI: 10.1007/s00270-007-9005-x
    • Vikram R, Ross RA, Bhat R, et al. Cutting balloon angioplasty versus standard balloon angioplasty for failing infra-inguinal vein grafts: comparative study of short- and mid-term primary patency rates. Cardiovasc Intervent Radiol 2007. DOI: 10.1007/s00270-007-9005-x.
    • Cardiovasc Intervent Radiol , vol.2007
    • Vikram, R.1    Ross, R.A.2    Bhat, R.3
  • 24
    • 33644671049 scopus 로고    scopus 로고
    • Meta-analysis of popliteal-to-distal vein bypass grafts for critical ischemia
    • Albers M, Romiti M, Brochado-Neto FC, et al. Meta-analysis of popliteal-to-distal vein bypass grafts for critical ischemia. J Vasc Surg 2006;43:498-503.
    • (2006) J Vasc Surg , vol.43 , pp. 498-503
    • Albers, M.1    Romiti, M.2    Brochado-Neto, F.C.3
  • 25
    • 0033629252 scopus 로고    scopus 로고
    • Infrapopliteal percutaneous transluminal angioplasty for limb salvage
    • Boyer L, Therre T, Garcier JM, et al. Infrapopliteal percutaneous transluminal angioplasty for limb salvage. Acta Radiol 2000;41: 73-7.
    • (2000) Acta Radiol , vol.41 , pp. 73-77
    • Boyer, L.1    Therre, T.2    Garcier, J.M.3
  • 26
    • 34247369842 scopus 로고    scopus 로고
    • Analysis of agreement between duplex ultrasound scanning and arteriography in patients with lower limb artery disease
    • Favaretto E, Pili C, Amato A, et al. Analysis of agreement between duplex ultrasound scanning and arteriography in patients with lower limb artery disease. J Cardiovasc Med (Hagerstown) 2007;8: 337-41.
    • (2007) J Cardiovasc Med (Hagerstown) , vol.8 , pp. 337-341
    • Favaretto, E.1    Pili, C.2    Amato, A.3
  • 27
    • 31144477884 scopus 로고    scopus 로고
    • PTA versus carbofilm-coated stents in infrapopliteal arteries: Pilot study
    • Rand T, Basile A, Cejna M, et al. PTA versus carbofilm-coated stents in infrapopliteal arteries: pilot study. Cardiovasc Intervent Radiol 2006;29:29-38.
    • (2006) Cardiovasc Intervent Radiol , vol.29 , pp. 29-38
    • Rand, T.1    Basile, A.2    Cejna, M.3
  • 28
    • 35848946377 scopus 로고    scopus 로고
    • Nitinol stenting for the treatment of below-the-knee critical limb ischemia: 1-year angiographic outcome of the Xpert stent
    • Bosiers M, Deloose K, Verbist J, Peeters P. Nitinol stenting for the treatment of below-the-knee critical limb ischemia: 1-year angiographic outcome of the Xpert stent. J Cardiovasc Surg (Torino) 2007;48:455-61.
    • (2007) J Cardiovasc Surg (Torino) , vol.48 , pp. 455-461
    • Bosiers, M.1    Deloose, K.2    Verbist, J.3    Peeters, P.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.