메뉴 건너뛰기




Volumn 20, Issue 3, 2009, Pages 195-199

Comparison of 25, 23 and 20-gauge vitrectomy

Author keywords

20 gauge; 23 gauge; 25 gauge; Pars plana vitrectomy; Sutureless vitrectomy

Indexed keywords

SILICONE OIL;

EID: 65549168312     PISSN: 10408738     EISSN: None     Source Type: Journal    
DOI: 10.1097/ICU.0b013e328329eaea     Document Type: Review
Times cited : (84)

References (26)
  • 1
    • 0015302220 scopus 로고
    • Vitrectomy: A pars plana approach. Technical improvements and further results
    • Machemer R, Parel JM, Norton EW. Vitrectomy: a pars plana approach. Technical improvements and further results. Trans Am Acad Ophthalmol Otolaryngol 1972; 76:462-466.
    • (1972) Trans Am Acad Ophthalmol Otolaryngol , vol.76 , pp. 462-466
    • Machemer, R.1    Parel, J.M.2    Norton, E.W.3
  • 2
    • 0016747701 scopus 로고
    • Vitrectomy with an alternative instrument system
    • O'Malley C, Heintz RM Sr. Vitrectomy with an alternative instrument system. Ann Ophthalmol 1975; 7:585-588; 591 -594.
    • (1975) Ann Ophthalmol , vol.7
    • O'Malley, C.1    Heintz Sr., R.M.2
  • 3
    • 0036480484 scopus 로고    scopus 로고
    • A new three-port cannular system for closed pars plana vitrectomy
    • Au Eong KG, Fujii GY, de Juan E Jr, Jensen PS, et al. A new three-port cannular system for closed pars plana vitrectomy. Retina. 2002; 22:130-132.
    • (2002) Retina , vol.22 , pp. 130-132
    • Au Eong, K.G.1    Fujii, G.Y.2    de Juan Jr, E.3    Jensen, P.S.4
  • 4
    • 18144392984 scopus 로고    scopus 로고
    • Longer-term outcomes of transconjunctival sutureless 25-gauge vitrectomy
    • Ibarra MS, Hermel M, Prenner JL, et al. Longer-term outcomes of transconjunctival sutureless 25-gauge vitrectomy. Am J Ophthalmol 2005; 139:831 - 836.
    • (2005) Am J Ophthalmol , vol.139 , pp. 831-836
    • Ibarra, M.S.1    Hermel, M.2    Prenner, J.L.3
  • 5
    • 67949085093 scopus 로고    scopus 로고
    • Miller DM, Riemann CD, Foster RE, e al. Primary repair of retinal detachment with 25-gauge pars plana vitrectomy. Retina 2008; 28:931 -936.
    • Miller DM, Riemann CD, Foster RE, e( al. Primary repair of retinal detachment with 25-gauge pars plana vitrectomy. Retina 2008; 28:931 -936.
  • 6
    • 67649658509 scopus 로고    scopus 로고
    • Retrospectively evaluated 42 that underwent 25-gauge transconjunctival sutureless vitrectomy for RRD. Single surgery anatomical success was achieved 92.9%, similar to 20-gauge historical norms.
    • Retrospectively evaluated 42 that underwent 25-gauge transconjunctival sutureless vitrectomy for RRD. Single surgery anatomical success was achieved 92.9%, similar to 20-gauge historical norms.
  • 7
    • 43249116182 scopus 로고    scopus 로고
    • Repair of primary rhegmatogenous retinal detachment using 25-gauge transconjunctival sutureless vitrectomy
    • Retrospectively evaluated 53 eyes that underwent 25-gauge transconjunctival sutureless vitrectomy for rhegmatogenous retinal detachment (RRD) and observed excellent final anatomical success rate. Single operation success rate was lower than historical norms
    • Lai MM, Ruby AJ, Sarrafizadeh R, et al. Repair of primary rhegmatogenous retinal detachment using 25-gauge transconjunctival sutureless vitrectomy. Retina 2008; 28:729-734. Retrospectively evaluated 53 eyes that underwent 25-gauge transconjunctival sutureless vitrectomy for rhegmatogenous retinal detachment (RRD) and observed excellent final anatomical success rate. Single operation success rate was lower than historical norms.
    • (2008) Retina , vol.28 , pp. 729-734
    • Lai, M.M.1    Ruby, A.J.2    Sarrafizadeh, R.3
  • 8
    • 33947136361 scopus 로고    scopus 로고
    • Outcomes of transconjunctival sutureless 25-gauge vitrectomy with silicone oil infusion
    • Riemann CD, Miller DM, Foster RE, et al. Outcomes of transconjunctival sutureless 25-gauge vitrectomy with silicone oil infusion. Retina 2007; 27: 296-303.
    • (2007) Retina , vol.27 , pp. 296-303
    • Riemann, C.D.1    Miller, D.M.2    Foster, R.E.3
  • 9
    • 37449017093 scopus 로고    scopus 로고
    • Removal of silicone oil with 25-gauge transconjunctival sutureless vitrectomy system
    • Kapran Z, Acar N. Removal of silicone oil with 25-gauge transconjunctival sutureless vitrectomy system. Retina 2007; 27:1059-1064.
    • (2007) Retina , vol.27 , pp. 1059-1064
    • Kapran, Z.1    Acar, N.2
  • 10
    • 42449146270 scopus 로고    scopus 로고
    • Tewari A, Shah GK, Fang A. Visual outcomes with 23-gauge transconjunctival sutureless vitrectomy. Retina 2008; 28:258-262.Reviewed 81 consecutive 23-gauge transconjunctival sutureless vitrectomies and found it to be an effective surgical technique with low complication rates.
    • Tewari A, Shah GK, Fang A. Visual outcomes with 23-gauge transconjunctival sutureless vitrectomy. Retina 2008; 28:258-262.Reviewed 81 consecutive 23-gauge transconjunctival sutureless vitrectomies and found it to be an effective surgical technique with low complication rates.
  • 11
    • 67649645209 scopus 로고    scopus 로고
    • Misra A, Ho-Yen G, Burton RL. 23-gauge sutureless vitrectomy and 20-gauge vitrectomy: a case series comparison. Eye 2008. [Epub ahead of print] Compared 23-gauge to 20-gauge PPV in 50 consecutive patients. 23-guage PPV was less likely to result in increased IOP and reduced surgical operating times.
    • Misra A, Ho-Yen G, Burton RL. 23-gauge sutureless vitrectomy and 20-gauge vitrectomy: a case series comparison. Eye 2008. [Epub ahead of print] Compared 23-gauge to 20-gauge PPV in 50 consecutive patients. 23-guage PPV was less likely to result in increased IOP and reduced surgical operating times.
  • 12
    • 58149268018 scopus 로고    scopus 로고
    • Primary 23-gauge transconjunctival sutureless vitrectomy for rhegmatogenous retinal detachment
    • Tsang CW, Cheung BT, Lam RF, et al. Primary 23-gauge transconjunctival sutureless vitrectomy for rhegmatogenous retinal detachment. Retina 2008; 28:1075-1081.
    • (2008) Retina , vol.28 , pp. 1075-1081
    • Tsang, C.W.1    Cheung, B.T.2    Lam, R.F.3
  • 13
    • 37349000924 scopus 로고    scopus 로고
    • Silicone oil tamponade in 23-gauge transconjunctival sutureless vitrectomy
    • Oliveira LB, Reis PA. Silicone oil tamponade in 23-gauge transconjunctival sutureless vitrectomy. Retina 2007; 27:1054-1058.
    • (2007) Retina , vol.27 , pp. 1054-1058
    • Oliveira, L.B.1    Reis, P.A.2
  • 14
    • 43549097592 scopus 로고    scopus 로고
    • Jamming of 25-gauge instruments in the cannula during vitrectomy for vitreous haemorrhage
    • Epub Oct 1
    • Shinoda H, Nakajima T, Shinoda K, et al. Jamming of 25-gauge instruments in the cannula during vitrectomy for vitreous haemorrhage. Acta Ophthalmol 2008; 86:160-164; Epub 2007 Oct 1.
    • (2007) Acta Ophthalmol 2008 , vol.86 , pp. 160-164
    • Shinoda, H.1    Nakajima, T.2    Shinoda, K.3
  • 15
    • 33645548087 scopus 로고    scopus 로고
    • 25-Gauge transconjunctival sutureless pars plana vitrectomy
    • Yanyali A, Celik E, Horozoglu F, et al. 25-Gauge transconjunctival sutureless pars plana vitrectomy. Eur J Ophthalmol 2006; 16:141-147.
    • (2006) Eur J Ophthalmol , vol.16 , pp. 141-147
    • Yanyali, A.1    Celik, E.2    Horozoglu, F.3
  • 16
    • 28444480731 scopus 로고    scopus 로고
    • Corneal topographic changes after transconjunctival (25-gauge) sutureless vitrectomy
    • Yanyali A, Celik E, Horozoglu F, et al. Corneal topographic changes after transconjunctival (25-gauge) sutureless vitrectomy. Am J Ophthalmol 2005; 140:939-941.
    • (2005) Am J Ophthalmol , vol.140 , pp. 939-941
    • Yanyali, A.1    Celik, E.2    Horozoglu, F.3
  • 17
    • 36549084604 scopus 로고    scopus 로고
    • Changes in corneal topography after 25-gauge transconjunctival sutureless vitrectomy versus after 20-gauge standard vitrectomy
    • Okamoto F, Okamoto C, Sakata N, Hiratsuka K, et al. Changes in corneal topography after 25-gauge transconjunctival sutureless vitrectomy versus after 20-gauge standard vitrectomy. Ophthalmology 2007; 114:2138-2141.
    • (2007) Ophthalmology , vol.114 , pp. 2138-2141
    • Okamoto, F.1    Okamoto, C.2    Sakata, N.3    Hiratsuka, K.4
  • 19
    • 67649669375 scopus 로고    scopus 로고
    • plana vitrectomy. Am J Ophthalmol 2008; 146:193-197.Reported initial and safety profile of 23-gauge PPV. Found low incidence of intraoperative and postoperative complications.
    • plana vitrectomy. Am J Ophthalmol 2008; 146:193-197.Reported initial and safety profile of 23-gauge PPV. Found low incidence of intraoperative and postoperative complications.
  • 20
    • 34547683880 scopus 로고    scopus 로고
    • Postoperative complications associated with 25-gauge pars plana vitrectomy
    • Gupta OP, Weichel ED, Regillo CD, et al. Postoperative complications associated with 25-gauge pars plana vitrectomy. Ophthalmic Surg Lasers Imaging 2007; 38:270-275.
    • (2007) Ophthalmic Surg Lasers Imaging , vol.38 , pp. 270-275
    • Gupta, O.P.1    Weichel, E.D.2    Regillo, C.D.3
  • 21
    • 36549012230 scopus 로고    scopus 로고
    • Kunimoto DY, Kaiser RS. Wills Eye Retina Service. Incidence of endophthalmitis after 20- and 25-gauge vitrectomy. Ophthalmology 2007; 114:2133-2137. Retrospectively evaluated endophthalmitis rates in 25-gauge compared to 20- gauge vitrectomy. Found a 12-fold higher incidence of endophthalmitis with 25- gauge vitrectomy.
    • Kunimoto DY, Kaiser RS. Wills Eye Retina Service. Incidence of endophthalmitis after 20- and 25-gauge vitrectomy. Ophthalmology 2007; 114:2133-2137. Retrospectively evaluated endophthalmitis rates in 25-gauge compared to 20- gauge vitrectomy. Found a 12-fold higher incidence of endophthalmitis with 25- gauge vitrectomy.
  • 22
    • 38049186578 scopus 로고    scopus 로고
    • Endophthalmitis after 25-gauge and 20-gauge pars plana vitrectomy: Incidence and outcomes
    • Scott IU, Flynn HW Jr, Dev S, et al. Endophthalmitis after 25-gauge and 20-gauge pars plana vitrectomy: incidence and outcomes. Retina 2008; 28:138-142.
    • (2008) Retina , vol.28 , pp. 138-142
    • Scott, I.U.1    Flynn Jr, H.W.2    Dev, S.3
  • 23
    • 67649159326 scopus 로고    scopus 로고
    • Incidence of endophthalmitis following 20-gauge and 25-gauge vitrectomy
    • Mason JO III, Yunker JJ, Vail RS, et al. Incidence of endophthalmitis following 20-gauge and 25-gauge vitrectomy. Retina 2008; 28:1352-1354.
    • (2008) Retina , vol.28 , pp. 1352-1354
    • Mason III, J.O.1    Yunker, J.J.2    Vail, R.S.3
  • 24
    • 54449098249 scopus 로고    scopus 로고
    • Hsu J, Chen E, Gupta O, et al. Hypotony after 25-gauge vitrectomy using oblique versus direct cannula insertions in fluid-filled eyes. Retina 2008;28:937-940.Evaluated hypotony rates after 25-gauge PPV with oblique versus straight cannula insertions. Found straight insertions resulted in lower mean postoperative day 1 IOP.
    • Hsu J, Chen E, Gupta O, et al. Hypotony after 25-gauge vitrectomy using oblique versus direct cannula insertions in fluid-filled eyes. Retina 2008;28:937-940.Evaluated hypotony rates after 25-gauge PPV with oblique versus straight cannula insertions. Found straight insertions resulted in lower mean postoperative day 1 IOP.
  • 25
    • 42449133895 scopus 로고    scopus 로고
    • Evaluation of wound closure using different incision techniques with 23-gauge and 25-gauge microincision vitrectomy systems
    • Singh RP, Bando H, Brasil OF, et al. Evaluation of wound closure using different incision techniques with 23-gauge and 25-gauge microincision vitrectomy systems. Retina 2008; 28:242-248.
    • (2008) Retina , vol.28 , pp. 242-248
    • Singh, R.P.1    Bando, H.2    Brasil, O.F.3
  • 26
    • 67649658511 scopus 로고    scopus 로고
    • Histopathologically evaluated oblique versus straight sclerotomy placement in rabbit eyes. Evidence of wound leak was more common in straight than oblique wounds
    • Histopathologically evaluated oblique versus straight sclerotomy placement in rabbit eyes. Evidence of wound leak was more common in straight than oblique wounds.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.