메뉴 건너뛰기




Volumn 7163, Issue , 2009, Pages

Omni-focal refractive focus correction technology as a substitute for bi/multi-focal intraocular lenses, contact lenses and spectacles

Author keywords

Astigmatism; Contact lenses; Intraocular lenses; Presbyopia; Spectacles

Indexed keywords

ASTIGMATISM; CLINICAL TRIALS; DEPTH OF FOCUS; IMAGING LENS; LOSS OF ENERGIES; OPHTHALMIC LENS; PRESBYOPIA; SPECTACLES;

EID: 65549154252     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.807349     Document Type: Conference Paper
Times cited : (6)

References (5)
  • 1
    • 33144459435 scopus 로고    scopus 로고
    • Traditional methods for the treatment of presbyopia: Spectacles, contact lenses, bifocal contact lenses
    • Callina, T, Reynolds TP, "Traditional methods for the treatment of presbyopia: spectacles, contact lenses, bifocal contact lenses," Ophthalmology Clinics of North America 19, 25-33 (2006).
    • (2006) Ophthalmology Clinics of North America , vol.19 , pp. 25-33
    • Callina, T.1    Reynolds, T.P.2
  • 2
    • 33746551237 scopus 로고    scopus 로고
    • New soft toric contact lenses; silicone hydrogel lens for astigmatism
    • Radu S., "New soft toric contact lenses; silicone hydrogel lens for astigmatism," J Oftalmologia 50, 59-62 (2006).
    • (2006) J Oftalmologia , vol.50 , pp. 59-62
    • Radu, S.1
  • 3
    • 33645503117 scopus 로고    scopus 로고
    • All-optical axial super resolving imaging using a low-frequency binary-phase mask
    • Zalevsky Z, Shemer A, Zlotnik A, Ben Eliezer E, Marom E., "All-optical axial super resolving imaging using a low-frequency binary-phase mask," Opt Express 14, 2631-2643 (2006).
    • (2006) Opt Express , vol.14 , pp. 2631-2643
    • Zalevsky, Z.1    Shemer, A.2    Zlotnik, A.3    Ben Eliezer, E.4    Marom, E.5
  • 4
    • 34548100639 scopus 로고    scopus 로고
    • Thin spectacles for myopia, presbyopia and astigmatism insensitive vision
    • Zalevsky Z, Ben Yaish S, Yehezkel O, Belkin M., "Thin spectacles for myopia, presbyopia and astigmatism insensitive vision," Opt Express 15, 10790-10803 (2007).
    • (2007) Opt Express , vol.15 , pp. 10790-10803
    • Zalevsky, Z.1    Ben Yaish, S.2    Yehezkel, O.3    Belkin, M.4
  • 5
    • 0031195491 scopus 로고    scopus 로고
    • Anatomically accurate, finite model eye for optical modeling
    • Liou H, Brennan NA., "Anatomically accurate, finite model eye for optical modeling," J Opt Soc Am. 14(8), 1684-1695 (1997).
    • (1997) J Opt Soc Am , vol.14 , Issue.8 , pp. 1684-1695
    • Liou, H.1    Brennan, N.A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.