메뉴 건너뛰기




Volumn 73, Issue 4, 2009, Pages 557-563

Simultaneous stent implantation to treat bifurcation stenoses in the pulmonary arteries: Initial results and long-term follow up

Author keywords

Bifurcating stents; Cardiac catheterization; Pulmonary artery stenoses

Indexed keywords

ADOLESCENT; ADULT; ARTICLE; BLOOD VESSEL DIAMETER; CHILD; CLINICAL ARTICLE; FEMALE; FOLLOW UP; HEART CATHETERIZATION; HUMAN; LONG TERM CARE; LUNG HEMORRHAGE; MALE; OUTCOME ASSESSMENT; PERCUTANEOUS TRANSLUMINAL ANGIOPLASTY; PULMONARY ARTERY STENOSIS; RETROSPECTIVE STUDY; STENT; SYSTOLIC BLOOD PRESSURE;

EID: 65549089122     PISSN: 15221946     EISSN: 1522726X     Source Type: Journal    
DOI: 10.1002/ccd.21838     Document Type: Article
Times cited : (40)

References (16)
  • 1
    • 33750063193 scopus 로고    scopus 로고
    • Acute and long-term results of bifurcation stenting (from the Coroflex Registry)
    • Rux S, Sonntag S, Schulze R, et al. Acute and long-term results of bifurcation stenting (from the Coroflex Registry). Am J Cardiol 2006;98:1214-1217.
    • (2006) Am J Cardiol , vol.98 , pp. 1214-1217
    • Rux, S.1    Sonntag, S.2    Schulze, R.3
  • 2
    • 33846805687 scopus 로고    scopus 로고
    • Simultaneous kissing stent technique to treat left main stem bifurcation disease
    • Morton AC, Siotia A, Arnold ND, et al., Simultaneous kissing stent technique to treat left main stem bifurcation disease. Catheter Cardiovasc Interv 2007;69:209-215.
    • (2007) Catheter Cardiovasc Interv , vol.69 , pp. 209-215
    • Morton, A.C.1    Siotia, A.2    Arnold, N.D.3
  • 4
    • 33751164436 scopus 로고    scopus 로고
    • Aortoiliac kissing stents: Long-term results and analysis of risk factors affecting patency
    • Yilmaz S, Sindel T, Golbasi I, Turkay C, Mete A, Luleci E. Aortoiliac kissing stents: Long-term results and analysis of risk factors affecting patency. J Endovasc Ther 2006;13:291-301.
    • (2006) J Endovasc Ther , vol.13 , pp. 291-301
    • Yilmaz, S.1    Sindel, T.2    Golbasi, I.3    Turkay, C.4    Mete, A.5    Luleci, E.6
  • 5
    • 0034950426 scopus 로고    scopus 로고
    • Three new applications of stent technology in a single patient
    • McMahon CJ, El-Said HG, Mullins CE. Three new applications of stent technology in a single patient. Tex Heart Inst J 2001;28:125-128.
    • (2001) Tex Heart Inst J , vol.28 , pp. 125-128
    • McMahon, C.J.1    El-Said, H.G.2    Mullins, C.E.3
  • 6
    • 0032032937 scopus 로고    scopus 로고
    • Intravascular stents in congenital heart disease: Short- and long-term results from a large single-center experience
    • Shaffer KM, Mullins CE, Grifka RG, et al. Intravascular stents in congenital heart disease: Short- and long-term results from a large single-center experience. J Am Coll Cardiol 1998;31:661-667.
    • (1998) J Am Coll Cardiol , vol.31 , pp. 661-667
    • Shaffer, K.M.1    Mullins, C.E.2    Grifka, R.G.3
  • 7
    • 0029147365 scopus 로고
    • Repeat dilation of intravascular stents in congenital heart defects
    • Ing FF, Grifka RG, Nihill MR, Mullins CE. Repeat dilation of intravascular stents in congenital heart defects. Circulation 1995;92:893-897.
    • (1995) Circulation , vol.92 , pp. 893-897
    • Ing, F.F.1    Grifka, R.G.2    Nihill, M.R.3    Mullins, C.E.4
  • 8
    • 0034893299 scopus 로고    scopus 로고
    • Redilation of endovascular stents in congenital heart disease: Factors implicated in the development of restenoses and neointimal proliferation
    • McMahon CJ, El-Said HG, Grifka RG, Fraley JK, Nihill MR, Mullins CE. Redilation of endovascular stents in congenital heart disease: Factors implicated in the development of restenoses and neointimal proliferation. J Am Coll Cardiol 2001;38:521-526.
    • (2001) J Am Coll Cardiol , vol.38 , pp. 521-526
    • McMahon, C.J.1    El-Said, H.G.2    Grifka, R.G.3    Fraley, J.K.4    Nihill, M.R.5    Mullins, C.E.6
  • 9
    • 0020529939 scopus 로고
    • Balloon dilation angioplasty of hypoplastic and stenotic pulmonary arteries
    • Lock JE, Castaneda-Zuniga WR, Fuhrman BP, Bass JL. Balloon dilation angioplasty of hypoplastic and stenotic pulmonary arteries. Circulation 1983;67:962-967.
    • (1983) Circulation , vol.67 , pp. 962-967
    • Lock, J.E.1    Castaneda-Zuniga, W.R.2    Fuhrman, B.P.3    Bass, J.L.4
  • 10
    • 0023906290 scopus 로고
    • Implantation of balloon-expandable intravascular grafts by catheterization in pulmonary arteries and systemic veins
    • Mullins CE, O'Laughlin MP, Vick GW III, et al. Implantation of balloon-expandable intravascular grafts by catheterization in pulmonary arteries and systemic veins. Circulation 1988;77:188-199.
    • (1988) Circulation , vol.77 , pp. 188-199
    • Mullins, C.E.1    O'Laughlin, M.P.2    Vick III, G.W.3
  • 11
  • 12
    • 33746046757 scopus 로고    scopus 로고
    • What is the current option of first choice for treatment of pulmonary arterial stenoses?
    • Bergersen L, Lock JE. What is the current option of first choice for treatment of pulmonary arterial stenoses? Cardiol Young 2006;16:329-338.
    • (2006) Cardiol Young , vol.16 , pp. 329-338
    • Bergersen, L.1    Lock, J.E.2
  • 13
    • 28644445175 scopus 로고    scopus 로고
    • Recent results of pulmonary arterial angioplasty: The differences between proximal and distal lesions
    • Bergersen L, Gauvreau K, Lock JE, Jenkins KJ. Recent results of pulmonary arterial angioplasty: The differences between proximal and distal lesions. Cardiol Young 2005;15:597-604.
    • (2005) Cardiol Young , vol.15 , pp. 597-604
    • Bergersen, L.1    Gauvreau, K.2    Lock, J.E.3    Jenkins, K.J.4
  • 16
    • 28644448548 scopus 로고    scopus 로고
    • Follow-up results of cutting balloon angioplasty used to relieve stenoses in small pulmonary arteries
    • Bergersen L, Jenkins KJ, Gauvreau K, Lock JE. Follow-up results of cutting balloon angioplasty used to relieve stenoses in small pulmonary arteries. Cardiol Young 2005;15:605-610.
    • (2005) Cardiol Young , vol.15 , pp. 605-610
    • Bergersen, L.1    Jenkins, K.J.2    Gauvreau, K.3    Lock, J.E.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.