메뉴 건너뛰기




Volumn 17, Issue 1, 2009, Pages 40-43

Use of an amplatzer vascular plug for transcatheter embolization of a renal arteriovenous fistula

Author keywords

Amplatzer vascular plug; Arteriovenous fistula; Embolization; Renal

Indexed keywords

AGED; ANAMNESIS; ARTICLE; ARTIFICIAL EMBOLISM; CASE REPORT; CATHETER; CLINICAL FEATURE; COMPUTED TOMOGRAPHIC ANGIOGRAPHY; COMPUTER ASSISTED TOMOGRAPHY; ECHOCARDIOGRAPHY; FEMALE; GUIDE WIRE; HEART LEFT VENTRICLE HYPERTROPHY; HEMATURIA; HUMAN; KIDNEY ARTERIOVENOUS FISTULA; PHYSICAL EXAMINATION; PREOPERATIVE EVALUATION; PRIORITY JOURNAL; TREATMENT RESPONSE; UROLOGY; VASODILATATION; ARTERIOVENOUS FISTULA; BLOOD FLOW VELOCITY; INSTRUMENTATION; KIDNEY VEIN; METHODOLOGY; PULSATILE FLOW; RADIOGRAPHY; RENAL ARTERY; TREATMENT OUTCOME;

EID: 65549088564     PISSN: 17085381     EISSN: None     Source Type: Journal    
DOI: 10.2310/6670.2008.00071     Document Type: Article
Times cited : (18)

References (9)
  • 1
    • 0034915795 scopus 로고    scopus 로고
    • Displacement of coils into the lung during embolotherapy: Clinical importance and follow-up with helical CT
    • Prokesch RW, Bankier AA, Ba-Ssalamah A, et al. Displacement of coils into the lung during embolotherapy: clinical importance and follow-up with helical CT. Acad Radiol 2001;8:501-8.
    • (2001) Acad Radiol , vol.8 , pp. 501-508
    • Prokesch, R.W.1    Bankier, A.A.2    Ba-Ssalamah, A.3
  • 3
    • 0027770421 scopus 로고
    • Recent advances in the diagnosis and treatment of renal arteriovenous malformations and fistulas
    • Crotty KL, Orihuela E, Warren MM. Recent advances in the diagnosis and treatment of renal arteriovenous malformations and fistulas. J Urol 1993;150:1355-9.
    • (1993) J Urol , vol.150 , pp. 1355-1359
    • Crotty, K.L.1    Orihuela, E.2    Warren, M.M.3
  • 4
    • 33644896818 scopus 로고    scopus 로고
    • Surgery for giant high-flow renal arteriovenous fistula: Experience in one institution
    • Osawa T, Watarai Y, Morita K, et al. Surgery for giant high-flow renal arteriovenous fistula: experience in one institution. BJU Int 2006;97:794-8.
    • (2006) BJU Int , vol.97 , pp. 794-798
    • Osawa, T.1    Watarai, Y.2    Morita, K.3
  • 5
    • 8544278905 scopus 로고    scopus 로고
    • High-output congestive heart failure successfully treated with transcatheter coil embolization of a large renal arteriovenous fistula
    • Bates MC, Almehmi A. High-output congestive heart failure successfully treated with transcatheter coil embolization of a large renal arteriovenous fistula. Catheter Cardiovasc Interv 2004;63:373-6.
    • (2004) Catheter Cardiovasc Interv , vol.63 , pp. 373-376
    • Bates, M.C.1    Almehmi, A.2
  • 6
    • 33746862198 scopus 로고    scopus 로고
    • Use of a partially deployed Wallstent to act as an inferior vena cava filtration device during coil embolization of a high-flow arteriovenous fistula
    • Resnick S, Rome V, Vogelzang R. Use of a partially deployed Wallstent to act as an inferior vena cava filtration device during coil embolization of a high-flow arteriovenous fistula. J Vasc Interv Radiol 2006;17:369-72.
    • (2006) J Vasc Interv Radiol , vol.17 , pp. 369-372
    • Resnick, S.1    Rome, V.2    Vogelzang, R.3
  • 7
    • 14944347245 scopus 로고    scopus 로고
    • Embolization of an acute renal arteriovenous fistula following a stab wound: Case report and review of the literature
    • Benson DA, Stockinger ZT, McSwain NE. Embolization of an acute renal arteriovenous fistula following a stab wound: case report and review of the literature. Am Surg 2005;71:62-5.
    • (2005) Am Surg , vol.71 , pp. 62-65
    • Benson, D.A.1    Stockinger, Z.T.2    McSwain, N.E.3
  • 8
    • 0036847344 scopus 로고    scopus 로고
    • The endovascular treatment of a renal arteriovenous fistula: Placement of a covered stent
    • Sprouse LR II, Hamilton IN Jr. The endovascular treatment of a renal arteriovenous fistula: placement of a covered stent. J Vasc Surg 2002; 36:1066-8.
    • (2002) J Vasc Surg , vol.36 , pp. 1066-1068
    • Sprouse II, L.R.1    Hamilton Jr., I.N.2
  • 9
    • 34247523171 scopus 로고    scopus 로고
    • Dual use of an Amplatzer device in the transcatheter embolization of a large high-flow renal arteriovenous fistula
    • Idowu O, Barodawala F, Nemeth A, et al. Dual use of an Amplatzer device in the transcatheter embolization of a large high-flow renal arteriovenous fistula. J Vasc Interv Radiol 2007;18:671-6.
    • (2007) J Vasc Interv Radiol , vol.18 , pp. 671-676
    • Idowu, O.1    Barodawala, F.2    Nemeth, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.