메뉴 건너뛰기




Volumn 35, Issue 5, 2009, Pages 748-755

Real-Time Myocardial Contrast Echocardiography in Rat: Infusion Versus Bolus Administration

Author keywords

Bolus; Infusion; Rat; Real time myocardial contrast echocardiography

Indexed keywords

BLOOD PERFUSIONS; BOLUS; CONTRAST AGENTS; CORONARY ARTERIES; EVANS BLUE STAINING; EVANS BLUES; EX-VIVO; EXPONENTIAL FUNCTIONS; GOOD CORRELATIONS; HIGH QUALITIES; IMAGING ANALYSIS; INFUSION; LEFT ANTERIOR DESCENDING; MYOCARDIAL BLOOD FLOWS; MYOCARDIAL PERFUSIONS; PEAK SIGNAL INTENSITIES; PERFUSION DEFECTS; QUANTITATIVE ANALYSIS; REAL-TIME MYOCARDIAL CONTRAST ECHOCARDIOGRAPHY; SIGNAL INTENSITIES; SPRAGUE-DAWLEY RATS; ULTRASOUND CONTRAST AGENTS;

EID: 65449136731     PISSN: 03015629     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ultrasmedbio.2008.09.018     Document Type: Article
Times cited : (11)

References (17)
  • 1
    • 0034680023 scopus 로고    scopus 로고
    • Diagnostic efficacy of sonovue
    • Bokor D. Diagnostic efficacy of sonovue. Am J Cardiol 86 Suppl (2000) 19G-24G
    • (2000) Am J Cardiol , vol.86 , Issue.SUPPL
    • Bokor, D.1
  • 2
    • 4143135386 scopus 로고    scopus 로고
    • Evaluation of cardioprotective effects of recombinant soluble P-selectin glycoprotein ligand-immunoglobulin in myocardial ischemia-reperfusion injury by real-time myocardial contrast echocardiography
    • Hansen A., Kumar A., Wolf D., Frankenbergerova K., Filusch A., Gross M.L., Mueller S., Katus H., and Kuecherer H. Evaluation of cardioprotective effects of recombinant soluble P-selectin glycoprotein ligand-immunoglobulin in myocardial ischemia-reperfusion injury by real-time myocardial contrast echocardiography. J Am Coll Cardiol 44 (2004) 887-891
    • (2004) J Am Coll Cardiol , vol.44 , pp. 887-891
    • Hansen, A.1    Kumar, A.2    Wolf, D.3    Frankenbergerova, K.4    Filusch, A.5    Gross, M.L.6    Mueller, S.7    Katus, H.8    Kuecherer, H.9
  • 4
    • 65449139116 scopus 로고    scopus 로고
    • Evaluation of cardiac function and myocardial perfusion in small animals: Capability of echocardiography
    • Ishikura F., Asanuma T., Ohtani K., and Beppu S. Evaluation of cardiac function and myocardial perfusion in small animals: Capability of echocardiography. Int Cong Series 1274 (2004) 195-197
    • (2004) Int Cong Series , vol.1274 , pp. 195-197
    • Ishikura, F.1    Asanuma, T.2    Ohtani, K.3    Beppu, S.4
  • 5
    • 33846618743 scopus 로고    scopus 로고
    • High-resolution myocardial perfusion imaging in mice with high-frequency echocardiographic detection of a depot contrast agent
    • Kaufmann B.A., Lankford M., Behm C.Z., French B.A., Klibanov A.L., Xu Y., and Lindner J.R. High-resolution myocardial perfusion imaging in mice with high-frequency echocardiographic detection of a depot contrast agent. J Am Soc Echocardiogr 20 (2007) 136-143
    • (2007) J Am Soc Echocardiogr , vol.20 , pp. 136-143
    • Kaufmann, B.A.1    Lankford, M.2    Behm, C.Z.3    French, B.A.4    Klibanov, A.L.5    Xu, Y.6    Lindner, J.R.7
  • 6
    • 0024592182 scopus 로고
    • Assessment of regional myocardial blood flow with myocardial contrast two-dimensional echocardiography
    • Kaul S., Kelly P., Oliner J.D., Glasheen W.P., Keller M.W., and Watson D.D. Assessment of regional myocardial blood flow with myocardial contrast two-dimensional echocardiography. J Am Coll Cardiol 13 (1989) 468-482
    • (1989) J Am Coll Cardiol , vol.13 , pp. 468-482
    • Kaul, S.1    Kelly, P.2    Oliner, J.D.3    Glasheen, W.P.4    Keller, M.W.5    Watson, D.D.6
  • 7
    • 34249698579 scopus 로고    scopus 로고
    • Monitoring left ventricular function in small animals
    • Lahoutte T. Monitoring left ventricular function in small animals. J Nucl Cardiol 14 (2007) 371-379
    • (2007) J Nucl Cardiol , vol.14 , pp. 371-379
    • Lahoutte, T.1
  • 8
    • 0035162511 scopus 로고    scopus 로고
    • Quantitative assessment of myocardial perfusion during graded coronary stenosis by real-time myocardial contrast echo refilling curves
    • Masugata H., Peters B., Lafitte S., Strachan G.M., Ohmori K., and DeMaria A.N. Quantitative assessment of myocardial perfusion during graded coronary stenosis by real-time myocardial contrast echo refilling curves. J Am Coll Cardiol 37 (2001) 262-269
    • (2001) J Am Coll Cardiol , vol.37 , pp. 262-269
    • Masugata, H.1    Peters, B.2    Lafitte, S.3    Strachan, G.M.4    Ohmori, K.5    DeMaria, A.N.6
  • 9
    • 57649227507 scopus 로고    scopus 로고
    • An original methodology for quantitative assessment of perfusion in small animal studies using contrast-enhanced ultrasound
    • Mulé S., De Cesare A., Frouin F., Lucidarme O., and Herment A. An original methodology for quantitative assessment of perfusion in small animal studies using contrast-enhanced ultrasound. Conf Proc IEEE Eng Med Biol Soc 1 (2007) 347-350
    • (2007) Conf Proc IEEE Eng Med Biol Soc , vol.1 , pp. 347-350
    • Mulé, S.1    De Cesare, A.2    Frouin, F.3    Lucidarme, O.4    Herment, A.5
  • 10
    • 0036110851 scopus 로고    scopus 로고
    • Myocardial perfusion imaging using contrast echocardiography
    • Nesser H.J., Morcerf F., Teupe C., and Pandian N.G. Myocardial perfusion imaging using contrast echocardiography. Herz 27 (2002) 2172-2261
    • (2002) Herz , vol.27 , pp. 2172-2261
    • Nesser, H.J.1    Morcerf, F.2    Teupe, C.3    Pandian, N.G.4
  • 12
    • 0030095088 scopus 로고    scopus 로고
    • Myocardial contrast echocardiography: Development, applications, and future directions
    • Sheil M.L., Kaul S., and Spotnitz W.D. Myocardial contrast echocardiography: Development, applications, and future directions. Acad Radiol 3 (1996) 260-275
    • (1996) Acad Radiol , vol.3 , pp. 260-275
    • Sheil, M.L.1    Kaul, S.2    Spotnitz, W.D.3
  • 13
    • 0242693141 scopus 로고    scopus 로고
    • Differences in definity and optison microbubble destruction rates at a similar mechanical index with different real-time perfusion systems
    • Sonne C., Xie F., Lof J., Oberdorfer J., Phillips P., Carr E.E., and Porter T.R. Differences in definity and optison microbubble destruction rates at a similar mechanical index with different real-time perfusion systems. J Am Soc Echocardiogr 16 (2003) 1178-1185
    • (2003) J Am Soc Echocardiogr , vol.16 , pp. 1178-1185
    • Sonne, C.1    Xie, F.2    Lof, J.3    Oberdorfer, J.4    Phillips, P.5    Carr, E.E.6    Porter, T.R.7
  • 15
    • 0032714578 scopus 로고    scopus 로고
    • Real-time contrast echo assessment of myocardial perfusion at low emission power: First experimental and clinical results using power pulse inversion imaging
    • R T
    • Tiemann K., Lohmeier S., Kuntz S., Köster J., Pohl C., Burns P., Nanda N.C., Lüderitz B., and Becher H. Real-time contrast echo assessment of myocardial perfusion at low emission power: First experimental and clinical results using power pulse inversion imaging. R T. Echocardiography 16 (1999) 7992-8091
    • (1999) Echocardiography , vol.16 , pp. 7992-8091
    • Tiemann, K.1    Lohmeier, S.2    Kuntz, S.3    Köster, J.4    Pohl, C.5    Burns, P.6    Nanda, N.C.7    Lüderitz, B.8    Becher, H.9
  • 16
    • 0032501992 scopus 로고    scopus 로고
    • Quantification of myocardial blood flow with ultrasound-induced destruction of microbubbles administered as a constant venous infusion
    • Wei K., Jayaweera A.R., Firoozan S., Linka A., Skyba D.M., and Kaul S. Quantification of myocardial blood flow with ultrasound-induced destruction of microbubbles administered as a constant venous infusion. Circulation 97 (1998) 473-483
    • (1998) Circulation , vol.97 , pp. 473-483
    • Wei, K.1    Jayaweera, A.R.2    Firoozan, S.3    Linka, A.4    Skyba, D.M.5    Kaul, S.6
  • 17
    • 0032127747 scopus 로고    scopus 로고
    • Basis for detection of stenosis using venous administration of microbubbles during myocardial contrast echocardiography: Bolus or continuous infusion?
    • Wei K., Jayaweera A.R., Firoozan S., Linka A., Skyba D.M., and Kaul S. Basis for detection of stenosis using venous administration of microbubbles during myocardial contrast echocardiography: Bolus or continuous infusion?. J Am Coll Cardiol 32 (1998) 252-260
    • (1998) J Am Coll Cardiol , vol.32 , pp. 252-260
    • Wei, K.1    Jayaweera, A.R.2    Firoozan, S.3    Linka, A.4    Skyba, D.M.5    Kaul, S.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.