메뉴 건너뛰기




Volumn 23, Issue 8, 1999, Pages 347-353

Evaluation of ventilatory pattern and respiratory work with the amplified spontaneous pattern (ASP);Evaluacion del patron ventilatorio y del trabajo respiratorio con el patron espontaneo amplificado (PEA)

Author keywords

'T' tube; Pressure support; Weaning; Work of breathing

Indexed keywords

ARTICLE; ASSISTED VENTILATION; BREATHING; CLINICAL ARTICLE; COMPARATIVE STUDY; EXTUBATION; HUMAN; LUNG FUNCTION TEST; LUNG MINUTE VOLUME; LUNG PRESSURE; MEDICAL INSTRUMENTATION; PATIENT MONITORING; RESPIRATORY AIRFLOW; T TUBE;

EID: 6544264927     PISSN: 02105691     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (2)

References (20)
  • 1
    • 0027946332 scopus 로고
    • Comparison of three methods of gradual withdrawal from ventilatory support during weaning from mechanical ventilation
    • Brochard L, Rauss A, Benito S, Conti G, Mancebo J, Rekik N, et al. Comparison of three methods of gradual withdrawal from ventilatory support during weaning from mechanical ventilation. Am J Respir Crit Care Med 1994; 150: 896-903.
    • (1994) Am J Respir Crit Care Med , vol.150 , pp. 896-903
    • Brochard, L.1    Rauss, A.2    Benito, S.3    Conti, G.4    Mancebo, J.5    Rekik, N.6
  • 3
    • 10544248173 scopus 로고    scopus 로고
    • Effect on the duration of mechanical ventilation of identifying patients capable of breathing spontaneously
    • Ely EW, Baker AM, Dunagan DP, Burke HL, Smith AC, Kelly PT, et al. Effect on the duration of mechanical ventilation of identifying patients capable of breathing spontaneously. N Engl J Med 1996; 335: 1.864-1.869.
    • (1996) N Engl J Med , vol.335 , pp. 1864-1869
    • Ely, E.W.1    Baker, A.M.2    Dunagan, D.P.3    Burke, H.L.4    Smith, A.C.5    Kelly, P.T.6
  • 6
    • 0026409412 scopus 로고
    • Positive end-expiratory pressure vs T-piece. Extubation after mechanical ventilation
    • Jones DP, Byrne P, Morgan C, Fraser I, Hyland R. Positive end-expiratory pressure vs T-piece. Extubation after mechanical ventilation. Chest 1991; 100: 1.655-1.659.
    • (1991) Chest , vol.100 , pp. 1655-1659
    • Jones, D.P.1    Byrne, P.2    Morgan, C.3    Fraser, I.4    Hyland, R.5
  • 8
    • 0020469123 scopus 로고
    • A simple method for assessing the validity of esophageal balloon technique
    • Baydur A, Behrakis K, Zin A, Jaeger M, Milic-Emili J. A simple method for assessing the validity of esophageal balloon technique. Am Rev Respir Dis 1982; 126: 788-791.
    • (1982) Am Rev Respir Dis , vol.126 , pp. 788-791
    • Baydur, A.1    Behrakis, K.2    Zin, A.3    Jaeger, M.4    Milic-Emili, J.5
  • 9
    • 0027482281 scopus 로고
    • The Bicore pulmonary monitor. A device to assess the work of breathing while weaning from mechanical ventilation
    • Petros AJ, Lamond CT, Bennett D. The Bicore pulmonary monitor. A device to assess the work of breathing while weaning from mechanical ventilation. Anaesthesia 1993; 48: 985-988.
    • (1993) Anaesthesia , vol.48 , pp. 985-988
    • Petros, A.J.1    Lamond, C.T.2    Bennett, D.3
  • 10
    • 0028269432 scopus 로고
    • Components of the work of breathing and implications for monitoring ventilator-dependent patients
    • Banner MJ, Jaeger MJ, Kirby RR. Components of the work of breathing and implications for monitoring ventilator-dependent patients. Crit Care Med 1994; 22: 515-523.
    • (1994) Crit Care Med , vol.22 , pp. 515-523
    • Banner, M.J.1    Jaeger, M.J.2    Kirby, R.R.3
  • 12
    • 0014766163 scopus 로고
    • The work of breathing: Potential for clinical application and the results of studies performed on 100 normal males
    • Ballantine TVN, Proctor HJ, Broussard ND, Lit BD. The work of breathing: potential for clinical application and the results of studies performed on 100 normal males Ann Surg 1970; 171: 590-594.
    • (1970) Ann Surg , vol.171 , pp. 590-594
    • Ballantine, T.V.N.1    Proctor, H.J.2    Broussard, N.D.3    Lit, B.D.4
  • 13
    • 0028865762 scopus 로고
    • Elevated imposed work of breathing masquerading as ventilator weaning intolerance
    • Kirton OC, Dehaven CB, Morgan JP, Windsord J, Civetta JM. Elevated imposed work of breathing masquerading as ventilator weaning intolerance. Chest 1995; 108: 1.021-1.025.
    • (1995) Chest , vol.108 , pp. 1021-1025
    • Kirton, O.C.1    Dehaven, C.B.2    Morgan, J.P.3    Windsord, J.4    Civetta, J.M.5
  • 14
    • 0027317386 scopus 로고
    • Decreasing imposed work of the breathing apparatus to zero using pressure support ventilation
    • Banner MJ, Kirby RR, Blanch PB, Layon AJ. Decreasing imposed work of the breathing apparatus to zero using pressure support ventilation. Crit Care Med 1993; 21: 1.333-1.338.
    • (1993) Crit Care Med , vol.21 , pp. 1333-1338
    • Banner, M.J.1    Kirby, R.R.2    Blanch, P.B.3    Layon, A.J.4
  • 15
    • 84866231288 scopus 로고    scopus 로고
    • Efectos fisiológicos del patrón espontáneo amplificado y la presión de soporte sobre el trabajo y patrón respiratono
    • Santos JA, Romero E, Subirana M, Mancebo J. Efectos fisiológicos del patrón espontáneo amplificado y la presión de soporte sobre el trabajo y patrón respiratono. Med Intensiva 1998;22 (Suplemento 1):253
    • (1998) Med Intensiva , vol.22 , Issue.1 SUPLEMENTO , pp. 253
    • Santos, J.A.1    Romero, E.2    Subirana, M.3    Mancebo, J.4
  • 16
    • 0033127005 scopus 로고    scopus 로고
    • Evaluación de la ventilación con patrón espontáneo amplificado en pacientes postoperados. Comparación con la presión de soporte
    • en prensa
    • Sanchez-De Merás A, Paiz P, Perpiñán Y, García Polit S, Soliveres J, Aguilar G, et al Evaluación de la ventilación con patrón espontáneo amplificado en pacientes postoperados. Comparación con la presión de soporte. Revista Española de Anestesia 1999: Volumen 46 (en prensa)
    • (1999) Revista Española de Anestesia , vol.46
    • Sanchez-De Merás, A.1    Paiz, P.2    Perpiñán, Y.3    García Polit, S.4    Soliveres, J.5    Aguilar, G.6
  • 17
    • 0026054873 scopus 로고
    • Inspiratory pressure support compensates for the additional work of breathing caused by the endotracheal tube
    • Brochard L, Rua F, Lorino H, Lemaire F, Harf A. Inspiratory pressure support compensates for the additional work of breathing caused by the endotracheal tube Anesthesiology 1991; 75: 739-754.
    • (1991) Anesthesiology , vol.75 , pp. 739-754
    • Brochard, L.1    Rua, F.2    Lorino, H.3    Lemaire, F.4    Harf, A.5
  • 19
    • 0027538014 scopus 로고
    • Prediction of minimal pressure support during weaning from mechanical ventilation
    • Nathan SD, Ishaaya AM, Koerner SK, Belman MJ. Prediction of minimal pressure support during weaning from mechanical ventilation. Chest 1993; 103: 1.215-1.219.
    • (1993) Chest , vol.103 , pp. 1215-1219
    • Nathan, S.D.1    Ishaaya, A.M.2    Koerner, S.K.3    Belman, M.J.4
  • 20
    • 0028813836 scopus 로고
    • Work of breathing after extubation
    • Ishaaya AM, Nathan SD, Belman MJ. Work of breathing after extubation. Chest 1995; 107:204-209.
    • (1995) Chest , vol.107 , pp. 204-209
    • Ishaaya, A.M.1    Nathan, S.D.2    Belman, M.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.