메뉴 건너뛰기




Volumn 7172, Issue , 2009, Pages

Combined spectrally encoded confocal microscopy and optical frequency domain imaging system

Author keywords

Barrett's esophagus; Confocal microscopy; Optical coherence tomography

Indexed keywords

BARRETT'S ESOPHAGUS; CLINICAL STUDIES; CROSS-SECTIONAL IMAGES; DIAGNOSTIC ACCURACIES; DIFFERENT SIZES; FACE IMAGES; HIGH RESOLUTIONS; HIGH-LATERAL RESOLUTIONS; IMAGING MODALITIES; IMAGING TECHNOLOGIES; INTERNAL ORGANS; MICROSCOPIC FEATURES; MULTI MODALITIES; OPTICAL COHERENCE TOMOGRAPHY; OPTICAL DIAGNOSIS; OPTICAL FREQUENCY DOMAIN IMAGING; PENETRATION DEPTHS; SECM IMAGES; SMALL INTESTINES; TISSUE ARCHITECTURES;

EID: 65349190580     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.808028     Document Type: Conference Paper
Times cited : (3)

References (9)
  • 1
    • 0037075991 scopus 로고    scopus 로고
    • Clinical practice. Barrett's Esophagus
    • S. J. Spechler, "Clinical practice. Barrett's Esophagus," N Engl J Med346(11), 836-842 (2002)
    • (2002) N Engl J Med , vol.346 , Issue.11 , pp. 836-842
    • Spechler, S.J.1
  • 2
    • 0033061001 scopus 로고    scopus 로고
    • Jumbo biopsy forceps protocol still misses unsuspected cancer in Barrett's esophagus with high-grade dysplasia
    • G. W. Falk, T. W. Rice, J. R. Goldblum and J. E. Richter, "Jumbo biopsy forceps protocol still misses unsuspected cancer in Barrett's esophagus with high-grade dysplasia," Gastrointestinal Endoscopy49(2), 170-176 (1999)
    • (1999) Gastrointestinal Endoscopy , vol.49 , Issue.2 , pp. 170-176
    • Falk, G.W.1    Rice, T.W.2    Goldblum, J.R.3    Richter, J.E.4
  • 3
    • 0032132439 scopus 로고    scopus 로고
    • Spectrally encoded confocal microscopy
    • G. J. Tearney, R. H. Webb and B. E. Bouma, "Spectrally encoded confocal microscopy," Opt Lett23(15), 1152-1154 (1998)
    • (1998) Opt Lett , vol.23 , Issue.15 , pp. 1152-1154
    • Tearney, G.J.1    Webb, R.H.2    Bouma, B.E.3
  • 5
  • 6
    • 2942703878 scopus 로고    scopus 로고
    • Sensitivity advantage of swept source and Fourier domain optical coherence tomography
    • M. Choma, M. Sarunic, C. Yang and J. Izatt, "Sensitivity advantage of swept source and Fourier domain optical coherence tomography," Opt. Express11(18), 2183-2189 (2003)
    • (2003) Opt. Express , vol.11 , Issue.18 , pp. 2183-2189
    • Choma, M.1    Sarunic, M.2    Yang, C.3    Izatt, J.4
  • 9
    • 9144220962 scopus 로고    scopus 로고
    • Removing the depth-degeneracy in optical frequency domain imaging with frequency shifting
    • S. Yun, G. Tearney, J. de Boer and B. Bouma, "Removing the depth-degeneracy in optical frequency domain imaging with frequency shifting," Opt. Express12(20), 4822-4828 (2004)
    • (2004) Opt. Express , vol.12 , Issue.20 , pp. 4822-4828
    • Yun, S.1    Tearney, G.2    de Boer, J.3    Bouma, B.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.