메뉴 건너뛰기




Volumn 22, Issue 12, 2008, Pages 1453-1455

Interplay of aberrations and visual parameters in pseudophakic eyes

Author keywords

[No Author keywords available]

Indexed keywords

CATARACT EXTRACTION; COMA; CONTRAST SENSITIVITY; EDITORIAL; EYE REFRACTION; HUMAN; INTERMETHOD COMPARISON; LENS IMPLANT; MODULATION TRANSFER FUNCTION; PSEUDOPHAKIA; PUPIL; REFRACTION ERROR; RETINA; RETINA IMAGE; TILTING; VISION; VISION TEST; VISUAL ACUITY;

EID: 65349166217     PISSN: 0950222X     EISSN: 14765454     Source Type: Journal    
DOI: 10.1038/eye.2008.303     Document Type: Editorial
Times cited : (1)

References (26)
  • 1
    • 0038624481 scopus 로고
    • Effect of pupil size on visual acuity
    • Campbell FW, Gregory AH. Effect of pupil size on visual acuity. Nature 1960; 187: 1121-1123.
    • (1960) Nature , vol.187 , pp. 1121-1123
    • Campbell, F.W.1    Gregory, A.H.2
  • 2
    • 3042644326 scopus 로고    scopus 로고
    • Optical Quality Analysis System: Instrument for objective clinical evaluation of ocular optical quality
    • Güell JL, Pujol J, Arjona M, Diaz-Douton F, Artal P. Optical Quality Analysis System: instrument for objective clinical evaluation of ocular optical quality. J Cataract Refract Surg 2004; 30: 1598-1599.
    • (2004) J Cataract Refract Surg , vol.30 , pp. 1598-1599
    • Güell, J.L.1    Pujol, J.2    Arjona, M.3    Diaz-Douton, F.4    Artal, P.5
  • 3
    • 0032606749 scopus 로고    scopus 로고
    • Laser ray-tracing method for optical testing
    • Navarro R, Moreno-Barriuso E. Laser ray-tracing method for optical testing. Opt Lett 1999; 24: 951-953.
    • (1999) Opt Lett , vol.24 , pp. 951-953
    • Navarro, R.1    Moreno-Barriuso, E.2
  • 5
    • 0036357722 scopus 로고    scopus 로고
    • Contribution of the cornea and internal surfaces to the change of ocular aberrations with age
    • Artal P, Berrio E, Guirao A, Piers P. Contribution of the cornea and internal surfaces to the change of ocular aberrations with age. J Opt Soc Am A 2002; 19: 137-143.
    • (2002) J Opt Soc Am A , vol.19 , pp. 137-143
    • Artal, P.1    Berrio, E.2    Guirao, A.3    Piers, P.4
  • 6
    • 0035038095 scopus 로고    scopus 로고
    • Age-related changes in monochromatic wave aberrations in the human eye
    • McLellan JS, Marcos S, Burns SA. Age-related changes in monochromatic wave aberrations in the human eye. Invest Ophthalmol Vis Sci 2001; 42: 1390-1395.
    • (2001) Invest Ophthalmol Vis Sci , vol.42 , pp. 1390-1395
    • McLellan, J.S.1    Marcos, S.2    Burns, S.A.3
  • 7
    • 0035063189 scopus 로고    scopus 로고
    • The spherical aberration of the crystalline lens of the human eye
    • Smith G, Cox M, Calver R, Garner LF. The spherical aberration of the crystalline lens of the human eye. Vision Res 2001; 15: 235-243.
    • (2001) Vision Res , vol.15 , pp. 235-243
    • Smith, G.1    Cox, M.2    Calver, R.3    Garner, L.F.4
  • 8
    • 0028917431 scopus 로고
    • Analysis of intraocular straylight, especially in relation to age
    • van den Berg TJ. Analysis of intraocular straylight, especially in relation to age. Optom Vis Sci 1995; 72: 52-59.
    • (1995) Optom Vis Sci , vol.72 , pp. 52-59
    • van den Berg, T.J.1
  • 9
    • 0037387972 scopus 로고    scopus 로고
    • Impact of a modified optic design on visual function: Clinical comparative study
    • Mester U, Dillinger P, Anterist N. Impact of a modified optic design on visual function: clinical comparative study. J Cataract Refract Surg 2003; 29: 652-660.
    • (2003) J Cataract Refract Surg , vol.29 , pp. 652-660
    • Mester, U.1    Dillinger, P.2    Anterist, N.3
  • 11
    • 0036859728 scopus 로고    scopus 로고
    • Prospective randomized trial of an anterior surface modified prolate intraocular lens
    • Packer M, Fine IH, Hoffman RS, Piers PA. Prospective randomized trial of an anterior surface modified prolate intraocular lens. J Refract Surg 2002; 18: 692-696.
    • (2002) J Refract Surg , vol.18 , pp. 692-696
    • Packer, M.1    Fine, I.H.2    Hoffman, R.S.3    Piers, P.A.4
  • 12
    • 43049138747 scopus 로고    scopus 로고
    • Spherical aberration and contrast sensitivity in eyes implanted with aspheric and spherical intraocular lenses: A comparative study
    • Tzelikis PF, Akaishi L, Trindade FC, Boteon JE. Spherical aberration and contrast sensitivity in eyes implanted with aspheric and spherical intraocular lenses: a comparative study. Am J Ophthalmol 2008; 145(5): 827-833.
    • (2008) Am J Ophthalmol , vol.145 , Issue.5 , pp. 827-833
    • Tzelikis, P.F.1    Akaishi, L.2    Trindade, F.C.3    Boteon, J.E.4
  • 13
    • 33947595775 scopus 로고    scopus 로고
    • Contrast sensitivity and glare disability after implantation of AcryS of IQ Natural aspherical intraocular lens: Prospective randomized masked clinical trial
    • Pandita D, Raj SM, Vasavada VA, Vasavada VA, Kazi NS, Vasavada AR. Contrast sensitivity and glare disability after implantation of AcryS of IQ Natural aspherical intraocular lens: prospective randomized masked clinical trial. J Cataract Refract Surg 2007; 33: 603-610.
    • (2007) J Cataract Refract Surg , vol.33 , pp. 603-610
    • Pandita, D.1    Raj, S.M.2    Vasavada, V.A.3    Vasavada, V.A.4    Kazi, N.S.5    Vasavada, A.R.6
  • 14
    • 35348960381 scopus 로고    scopus 로고
    • Ocular aberrations and contrast sensitivity after cataract surgery with AcryS of IQ intraocular lens implantation Clinical comparative study
    • Tzelikis PF, Akaishi L, Trindade FC, Boteon JE. Ocular aberrations and contrast sensitivity after cataract surgery with AcryS of IQ intraocular lens implantation Clinical comparative study. J Cataract Refract Surg 2007; 33: 1918-1924.
    • (2007) J Cataract Refract Surg , vol.33 , pp. 1918-1924
    • Tzelikis, P.F.1    Akaishi, L.2    Trindade, F.C.3    Boteon, J.E.4
  • 15
    • 33750084170 scopus 로고    scopus 로고
    • Wavefront analysis contrast sensitivity of aspheric spherical intraocular lenses: A randomized prospective study
    • Rocha KM, Soriano ES, Chalita MR, Yamada AC, Bottós K, Bottós J et al. Wavefront analysis contrast sensitivity of aspheric spherical intraocular lenses: a randomized prospective study. Am J Ophthalmol 2006; 142: 750-756.
    • (2006) Am J Ophthalmol , vol.142 , pp. 750-756
    • Rocha, K.M.1    Soriano, E.S.2    Chalita, M.R.3    Yamada, A.C.4    Bottós, K.5    Bottós, J.6
  • 16
    • 0141643152 scopus 로고    scopus 로고
    • Retinal image contrast and functional visual performance with aspheric, silicone, and acrylic intraocular lenses: Prospective evaluation
    • Kershner RM. Retinal image contrast and functional visual performance with aspheric, silicone, and acrylic intraocular lenses: prospective evaluation. J Cataract Refract Surg 2003; 29: 1684-1694.
    • (2003) J Cataract Refract Surg , vol.29 , pp. 1684-1694
    • Kershner, R.M.1
  • 17
    • 33846571317 scopus 로고    scopus 로고
    • Quality of vision after cataract surgery after Tecnis Z9000 intraocular lens implantation: Effect of contrast sensitivity and wavefront aberration improvements on the quality of daily vision
    • Denoyer A, Le Lez ML, Majzoub S, Pisella PJ. Quality of vision after cataract surgery after Tecnis Z9000 intraocular lens implantation: effect of contrast sensitivity and wavefront aberration improvements on the quality of daily vision. J Cataract Refract Surg 2007; 33(2): 210-216.
    • (2007) J Cataract Refract Surg , vol.33 , Issue.2 , pp. 210-216
    • Denoyer, A.1    Le Lez, M.L.2    Majzoub, S.3    Pisella, P.J.4
  • 19
    • 0025775401 scopus 로고
    • Design of aspheric intraocular lenses
    • Atchison DA. Design of aspheric intraocular lenses. Ophthalmic Physiol Opt 1991; 11: 137-146.
    • (1991) Ophthalmic Physiol Opt , vol.11 , pp. 137-146
    • Atchison, D.A.1
  • 21
    • 65349090618 scopus 로고    scopus 로고
    • Kim SW, Ahn H, Kim EK, Kim T. Comparison of higher-order aberrations in eyes with aspherical or spherical intraocular lenses. Eye 2008; 22: 1493-1498 (this issue).
    • Kim SW, Ahn H, Kim EK, Kim T. Comparison of higher-order aberrations in eyes with aspherical or spherical intraocular lenses. Eye 2008; 22: 1493-1498 (this issue).
  • 22
    • 34447651161 scopus 로고    scopus 로고
    • Aberration and contrast sensitivity comparison of aspherical and monofocal and multifocal intraocular lens eyes
    • Zeng M, Liu Y, Liu X, Yuan Z, Luo L, Xia Y et al. Aberration and contrast sensitivity comparison of aspherical and monofocal and multifocal intraocular lens eyes. Clin Exp Ophthalmol 2007; 35: 355-360.
    • (2007) Clin Exp Ophthalmol , vol.35 , pp. 355-360
    • Zeng, M.1    Liu, Y.2    Liu, X.3    Yuan, Z.4    Luo, L.5    Xia, Y.6
  • 23
    • 34548713585 scopus 로고    scopus 로고
    • Prospective randomized study of clinical performance of 3 aspheric and 2 spherical intraocular lenses in 250 eyes
    • Caporossi A, Martone G, Casprini F, Rapisarda L. Prospective randomized study of clinical performance of 3 aspheric and 2 spherical intraocular lenses in 250 eyes. J Refract Surg 2007; 23: 639-648.
    • (2007) J Refract Surg , vol.23 , pp. 639-648
    • Caporossi, A.1    Martone, G.2    Casprini, F.3    Rapisarda, L.4
  • 25
    • 33846608607 scopus 로고    scopus 로고
    • Spherical aberration and coma with an aspherical and a spherical intraocular lens in normal age-matched eyes
    • Bellucci R, Morselli S, Pucci V. Spherical aberration and coma with an aspherical and a spherical intraocular lens in normal age-matched eyes. J Cataract Refract Surg 2007; 33: 203-209.
    • (2007) J Cataract Refract Surg , vol.33 , pp. 203-209
    • Bellucci, R.1    Morselli, S.2    Pucci, V.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.